The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
The Duration of Holter Monitoring in Patients With Syncope: Is 24 Hours Enough?
Abstract
To determine the incremental yield of ambulatory monitoring in the evaluation of syncope, three serial 24-hour Holter recordings were obtained in a consecutive series of 95 patients with syncope, the cause of which was not explained by history, physical examination, or 12-lead electrocardiogram. The mean age of patients was 61 years and 41% were men. Major electrocardiographic abnormalities were found in 26 patients (27%), including unsustained ventricular tachycardia (19 patients), pauses of at least 2 seconds (8 patients), profound bradycardia (1 patient), and complete heart block (1 patient). The first 24-hour Holter recording had at least one major abnormality in 14 patients (15%) (95% confidence interval, 8.3% to 23.4%). Of the 81 patients without a major abnormality on the first Holter recording, the second Holter recording had major abnormalities in 9 (11%) (95% confidence interval, 5.1% to 20.0%). Of the 72 patients without a major abnormality on the first two Holter recordings, only 3 patients (4.2%) had a major abnormality on the third Holter recording (95% confidence interval, 0.8% to 11.7%). Four factors were significantly associated with an increased likelihood of a major abnormality on 72 hours of monitoring: age above 65 years (relative risk, 2.2), male gender (relative risk, 2.0), history of heart disease (relative risk, 2.2), and an initial nonsinus rhythm (relative risk, 3.5). These results suggest that 24 hours of Holter monitoring is not enough to identify…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Holter monitoring and external loop recorders serve as main noninvasive monitoring strategies, but the diagnostic yield is low, especially in cases of infrequent symptoms [5,7].”
From Diagnostic Yield and Clinical Implications of Implantable Loop Recorders in Patients with Syncope in Germany: A National Database Analysis (2024) · cites this paper as [7]
In the citing paper
“In another study, the median time for recording a symptom-rhythm correlation was 16 days for patients assigned a loop recorder as their first diagnostic strategy and symptom-rhythm correlation was obtained in 87% of patients by 1 month of monitoring (Bass et al., 1990).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Bass et al., 1990
In the citing paper
“In 15% of patients, symptoms were not associated with arrhythmia. 161”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [161]
Citations
Cites
The publisher hasn’t deposited this paper’s reference list.
Cited by
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951
Guidelines on Management (diagnosis and treatment) of syncope ? update 2004
(2004) · Europace · doi:10.1016/j.eupc.2004.08.008 · Cited by 652
Metadata
- Authors
- Bass, E. B.
- Corresponding author
- Bass, Eric B.
- ORCID
- Bass, Eric B.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 1990-05-01
- Volume
- 150
- Issue
- 5
- Pages
- 1073
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W4247144249
- Cited by
- 156
- References
- 0
- Citations by year
- 2026: 1 · 2025: 9 · 2024: 3 · 2022: 6 · 2021: 5 · 2020: 3 · 2019: 5 · 2018: 10 · 2017: 4 · 2016: 3 · 2015: 9 · 2014: 7 · 2013: 10 · 2012: 5
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Archives of Internal Medicine (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (1RO1 HL36735, K04 HL01899)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- Holter monitoring, syncope, monitoring duration, cardiac arrhythmias, syncope etiology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Duration of Holter Monitoring in Patients With Syncope: Is 24 Hours Enough? https://app.cochat.ai/papers/10.1001/archinte.1990.00390170103022
- The paper
- Bass, E. B. (1990). The Duration of Holter Monitoring in Patients With Syncope: Is 24 Hours Enough? Archives of Internal Medicine. https://doi.org/10.1001/archinte.1990.00390170103022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.