The Duration of Holter Monitoring in Patients With Syncope: Is 24 Hours Enough?
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
To determine the incremental yield of ambulatory monitoring in the evaluation of syncope, three serial 24-hour Holter recordings were obtained in a consecutive series of 95 patients with syncope, the cause of which was not explained by history, physical examination, or 12-lead electrocardiogram. The mean age of patients was 61 years and 41% were men. Major electrocardiographic abnormalities were found in 26 patients (27%), including unsustained ventricular tachycardia (19 patients), pauses of at least 2 seconds (8 patients), profound bradycardia (1 patient), and complete heart block (1 patient). The first 24-hour Holter recording had at least one major abnormality in 14 patients (15%) (95% confidence interval, 8.3% to 23.4%). Of the 81 patients without a major abnormality on the first Holter recording, the second Holter recording had major abnormalities in 9 (11%) (95% confidence interval, 5.1% to 20.0%). Of the 72 patients without a major abnormality on the first two Holter recordings, only 3 patients (4.2%) had a major abnormality on the third Holter recording (95% confidence interval, 0.8% to 11.7%). Four factors were significantly associated with an increased likelihood of a major abnormality on 72 hours of monitoring: age above 65 years (relative risk, 2.2), male gender (relative risk, 2.0), history of heart disease (relative risk, 2.2), and an initial nonsinus rhythm (relative risk, 3.5). These results suggest that 24 hours of Holter monitoring is not enough to identify…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Holter monitoring and external loop recorders serve as main noninvasive monitoring strategies, but the diagnostic yield is low, especially in cases of infrequent symptoms [5,7].”
From Diagnostic Yield and Clinical Implications of Implantable Loop Recorders in Patients with Syncope in Germany: A National Database Analysis (2024) · cites this paper as [7]
In the citing paper
“In another study, the median time for recording a symptom-rhythm correlation was 16 days for patients assigned a loop recorder as their first diagnostic strategy and symptom-rhythm correlation was obtained in 87% of patients by 1 month of monitoring (Bass et al., 1990).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Bass et al., 1990
In the citing paper
“In 15% of patients, symptoms were not associated with arrhythmia. 161”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [161]
Citations
Cites
The publisher hasn’t deposited this paper’s reference list.
Cited by
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951
Guidelines on Management (diagnosis and treatment) of syncope ? update 2004
(2004) · Europace · doi:10.1016/j.eupc.2004.08.008 · Cited by 652
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Kapoor, W. N. (2000) · New England Journal of Medicine · doi:10.1056/nejm200012213432507 · Cited by 322
CLINICAL GUIDELINE: Diagnosing Syncope: Part 2: Unexplained Syncope
Linzer, M., Yang, E. H., Estes, N. A. M., Wang, P., Vorperian, V. R., & Kapoor, W. N. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-1-199707010-00014 · Cited by 313
Self-citationACC/AHA guidelines for ambulatory electrocardiography
Crawford, M. H., Bernstein, S. J., Deedwania, P. C., DiMarco, J. P., Ferrick, K. J., Garson, A., Green, L. A., Greene, H. L., Silka, M. J., Stone, P. H., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00354-x · Cited by 309
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
“In another study, the median time for recording a symptom–rhythm correlation was 16 days for patients assigned a loop recorder as their first diagnostic strategy and symptom–rhythm correlation was obtained in 87% of patients by 1 month of monitoring (Bass et al., 1990).”
MethodGuía de práctica clínica para el diagnóstico y manejo del síncope (versión 2009)
Moya, Á., Sutton, R., Ammirati, F., Blanc, J.-J., Brignole, M., Dahm, J. B., Deharo, J.-C., Gajek, J., Gjesdal, K., Krahn, A., et al. (2009) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(09)73541-8 · Cited by 276
Kadish, A. H., Buxton, A. E., Kennedy, H. L., Knight, B. P., Mason, J. W., Schuger, C. D., Tracy, C. M., Winters, W. L., Boone, A. W., Elnicki, M., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01680-1 · Cited by 244
Evaluation and Management of the Patient With Syncope
Kapoor, W. N. (1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490180085031 · Cited by 229
Wireless smartphone ECG enables large-scale screening in diverse populations
HABERMAN, Z. C., JAHN, R. T., BOSE, R., TUN, H., SHINBANE, J. S., DOSHI, R. N., CHANG, P. M., & SAXON, L. A. (2015) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12634 · Cited by 212
“44,45 Because many patients have a smartphone accessible nearly 24 hours a day, the smartphone ECG may also be useful in patients with rare or transient symptoms undetected by traditional event monitors or in patients who want a less invasive alternative and on-demand ability to record an ECG.…”
BackgroundAmbulatory Arrhythmia Monitoring: Choosing the Right Device
Zimetbaum, P., & Goldman, A. (2010) · Circulation · doi:10.1161/circulationaha.109.925610 · Cited by 209
ROTHMAN, S. A., LAUGHLIN, J. C., SELTZER, J., WALIA, J. S., BAMAN, R. I., SIOUFFI, S. Y., SANGRIGOLI, R. M., & KOWEY, P. R. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00729.x · Cited by 194
Committee Members, Kadish, A. H., Buxton, A. E., Kennedy, H. L., Knight, B. P., Mason, J. W., Schuger, C. D., Tracy, C. M., Winters, W. L., Boone, A. W., et al. (2001) · Circulation · doi:10.1161/circ.104.25.3169 · Cited by 192
Diagnostic evaluation of syncope
N. Kapoor, W. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90511-u · Cited by 177
Hoch, J. S., Rockx, M. A., & Krahn, A. D. (2006) · BMC Health Services Research · doi:10.1186/1472-6963-6-68 · Cited by 163
“Several studies have reported the diagnostic yield of the two monitoring modalities, suggesting a higher yield from the longer duration of monitoring provided by a loop recorder [3,7-12].”
BackgroundSivakumaran, S., Krahn, A. D., Klein, G. J., Finan, J., Yee, R., Renner, S., & Skanes, A. C. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00233-x · Cited by 160
Huff, J. S., Decker, W. W., Quinn, J. V., Perron, A. D., Napoli, A. M., Peeters, S., & Jagoda, A. S. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2007.02.001 · Cited by 157
“However, none of the patients with arrhythmias detected in the second and third 24-hour periods were symptomatic.(39) Laboratory testing.”
BackgroundMcKeon, A. B., Vaughan, C. J., & Delanty, N. (2006) · The Lancet Neurology · doi:10.1016/s1474-4422(06)70350-7 · Cited by 162
The Evolving Role of Ambulatory Arrhythmia Monitoring in General Clinical Practice
Zimetbaum, P. J., & Josephson, M. E. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-10-199905180-00020 · Cited by 139
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.036 · Cited by 144
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Holter Monitoring and Loop Recorders: From Research to Clinical Practice
Galli, A., Ambrosini, F., & Lombardi, F. (2016) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2016.17.2 · Cited by 143
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P. F., Balsam, P., Baranchuk, A. M., Cantillon, D. J., Dilaveris, P., Dubner, S., El‐Sherif, N., et al. (2017) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12447 · Cited by 133
“In another study, the median time for recording a symptom–rhythm correlation was 16 days for patients assigned a loop recorder as their first diagnostic strategy and symptom–rhythm correlation was obtained in 87% of patients by 1 month of monitoring (Bass et al., 1990).”
MethodSun, B. C., McCreath, H., Liang, L.-J., Bohan, S., Baugh, C., Ragsdale, L., Henderson, S. O., Clark, C., Bastani, A., Keeler, E., et al. (2014) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2013.10.029 · Cited by 114
Pires, L. A., Ganji, J. R., Jarandila, R., & Steele, R. (2001) · Archives of Internal Medicine · doi:10.1001/archinte.161.15.1889 · Cited by 106
“(%) Postural BP check 15 (6) 9 (60) 5 (33) 82 (41)‡ 30 (37) 21 (26) Continuous telemetry 252 (100) 7 (3) 3 (1) 199 (100) 4 (2) 1 (0.”
(2001) · Annals of Emergency Medicine · doi:10.1067/mem.2001.114838 · Cited by 92
How to avoid a misdiagnosis in patients presenting with transient loss of consciousness
Petkar, S., Cooper, P. N., & Fitzpatrick, A. P. (2006) · Postgraduate Medical Journal · doi:10.1136/pgmj.2006.046565 · Cited by 108
Utility of Patient-Activated Cardiac Event Recorders in General Clinical Practice
Zimetbaum, P., Kim, K. Y., Ho, K. K. L., Zebede, J., Josephson, M. E., & Goldberger, A. L. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)00766-7 · Cited by 77
Detection of asymptomatic arrhythmias in unexplained syncope
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2004) · American Heart Journal · doi:10.1016/j.ahj.2004.01.024 · Cited by 76
Utility of Implantable Loop Recorder (Reveal Plus®) in the Diagnosis of Unexplained Syncope
LOMBARDI, F., CALOSSO, E., MASCIOLI, G., MARANGONI, E., DONATO, A., ROSSI, S., PALA, M., FOTI, F., & LUNATI, M. (2005) · Europace · doi:10.1016/j.eupc.2004.09.003 · Cited by 76
“Twenty-four hour Holter monitoring is of limited value in the diagnosis of syncope [1,2,13].”
BackgroundNATIONAL RUSSIAN GUIDELINES ON APPLICATION OF THE METHODS OF HOLTER MONITORING IN CLINICAL PRACTICE
Makarov, L. M., Komolyatova, V. N., Kupriyanova, O. A., Pervova, E. V., Ryabykina, G. V., Sobolev, A. V., Тихоненко, В. М., Туров, А. Н., Shubik, Y. V., Av, A., et al. (2014) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2014-2-6-71 · Cited by 147
Cardiovascular causes of falls
Carey, B. J., & Potter, J. F. (2001) · Age and Ageing · doi:10.1093/ageing/30.suppl_4.19 · Cited by 79
Kapoor, W. N. (1994) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1994.tb07493.x · Cited by 79
Schreiber, D., Sattar, A., Drigalla, D., & Higgins, S. (2014) · Western Journal of Emergency Medicine · doi:10.5811/westjem.2013.11.18973 · Cited by 65
Empowering Technology Enabled Care Using IoT and Smart Devices: A Review
Baali, H., Djelouat, H., Amira, A., & Bensaali, F. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2786301 · Cited by 63
“This time window is required as many abnormalities may occur as short episodes (few seconds) once in few days [33].”
BackgroundRockx, M. A., Hoch, J. S., Klein, G. J., Yee, R., Skanes, A. C., Gula, L. J., & Krahn, A. D. (2005) · American Heart Journal · doi:10.1016/j.ahj.2005.08.003 · Cited by 60
Long-term continuous external electrocardiographic recording: a review
Enseleit, F., & Duru, F. (2006) · EP Europace · doi:10.1093/europace/euj054 · Cited by 62
“Most arrhythmia studies use a 24-h period, although yield may be increased slightly with longer recordings or repeated recordings, especially in patients with unexplained syncope and concomitant diseases.(21)”
BackgroundCardiovascular assessment of falls in older people
Tan, M. P., & Kenny, R. A. (2006) · Clinical Interventions in Aging · doi:10.2147/ciia.2006.1.1.57 · Cited by 52
“The diagnostic rate in an unselected population is 1%–2% (Gibson and Heitzman 1984; Bass et al 1990; DiMarco and Philbrik 1990).”
BackgroundCauses of Syncope in Patients with Alzheimer???s Disease Treated with Donepezil
Bordier, P., Lanusse, S., Garrigue, S., Reynard, C., Robert, F., Gencel, L., & Lafitte, A. (2005) · Drugs & Aging · doi:10.2165/00002512-200522080-00005 · Cited by 51
Diagnostic Evaluation and Management of Patients with Syncope
Schnipper, J. L., & Kapoor, W. N. (2001) · Medical Clinics of North America · doi:10.1016/s0025-7125(05)70321-7 · Cited by 54
Optimal duration of monitoring in patients with unexplained syncope
Assar, M. D., Krahn, A. D., Klein, G. J., Yee, R. K., & Skanes, A. C. (2003) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2003.07.042 · Cited by 52
Workup and management of patients with syncope
Kapoor, W. N. (1995) · Medical Clinics of North America · doi:10.1016/s0025-7125(16)35877-1 · Cited by 54
Comparing 14-day Adhesive Patch With 24-h Holter Monitoring
Cheung, C. C., Kerr, C. R., & Krahn, A. D. (2014) · Future Cardiology · doi:10.2217/fca.14.24 · Cited by 46
Lyle, C. H., Turley, G., BLISSITT, K. J., Pirie, R. S., Mayhew, I. G., McGorum, B. C., & Keen, J. (2010) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2010.0610.x · Cited by 47
Allcock, L. M., & O'Shea, D. (2000) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/55.8.m458 · Cited by 43
Seidl, K., Schuchert, A., Tebbenjohanns, J., & Hartung, W. (2005) · Zeitschrift für Kardiologie · doi:10.1007/s00392-005-0230-5 · Cited by 51
“Im 48-Stunden-Langzeit-EKG erhöht sich der Anteil um weitere 11% und in der 72-Stunden-Langzeit-EKG-Aufzeichnung um nochmals 4% [40].”
BackgroundHolter, Loop Recorder, and Event Counter Capabilities of Implanted Devices
WAKTARE, J. E. P., & MALIK, M. (1997) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1997.tb06114.x · Cited by 40
Do patients with a negative Emergency Department evaluation for syncope require hospital admission?
Morag, R. M., Murdock, L. F., Khan, Z. A., Heller, M. J., & Brenner, B. E. (2004) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2004.04.017 · Cited by 39
Kothari, D., Riddell, F., Smith, W., Voss, J., & Skinner, J. R. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.07.018 · Cited by 42
Sarasin, F., Carballo, D., Slama, S., & Louis‐Simonet, M. (2004) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.03.016 · Cited by 41
Syncope: a review of emergency department management and disposition
Patel, P., & Quinn, J. (2015) · Clinical and Experimental Emergency Medicine · doi:10.15441/ceem.14.049 · Cited by 41
“In one study following 95 syncope patients, the majority of abnormalities found on 24-hour Holter recordings included bradycardia <30 beats per minute, sinus pauses >2 seconds, Mobitz II conduction block, complete heart block, ventricular tachycardia, and premature ventricular contractions.(33) These findings suggest…”
BackgroundForman, D. E., & Lipsitz, L. A. (1997) · Cardiology Clinics · doi:10.1016/s0733-8651(05)70337-4 · Cited by 36
Clinical validation of a low-power and wearable ECG patch for long term full-disclosure monitoring
Torfs, T., Smeets, C. J. P. P., Geng, D., Berset, T., der Auwera, J. V., Vandervoort, P. M., & Grieten, L. (2014) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2014.08.012 · Cited by 35
Sinha, P., Zurakowski, D., He, D., Yerebakan, C., Freedenberg, V. A., Moak, J. P., & Jonas, R. A. (2012) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2012.03.080 · Cited by 36
“31) at a median of 198 days (interquartile range, 50–495) postoperatively (98 days [34–380] in the IE group, 381 days [110–934] in the LT group, and 27 days [6–57] in the EC group) (P 1⁄4 .”
BackgroundEVALUATION OF SYNCOPE IN THE EMERGENCY DEPARTMENT
Hayes, O. W. (1998) · Emergency Medicine Clinics of North America · doi:10.1016/s0733-8627(05)70020-1 · Cited by 32
Kühne, M., Schaer, B. A., Moulay, N., Sticherling, C., & Osswald, S. (2007) · QJM · doi:10.1093/qjmed/hcm104 · Cited by 31
“Monitoring may need to be extended to 48 h if the first 24 h of monitoring is normal.(19) It seems obvious that this strategy potentially identifies more, but certainly not all relevant arrhythmias.”
BackgroundMethodReed, M. J., Grubb, N. R., Lang, C. C., Gray, A. J., Simpson, K., MacRaild, A., & Weir, C. J. (2018) · Emergency Medicine Journal · doi:10.1136/emermed-2018-207570 · Cited by 28
Gámiz, J. L. P., Jiménez, A., González‐Juanatey, J. R., Huerta, E. M., & Martín-Ambrosio, E. S. (2000) · Revista Española de Cardiología · doi:10.1016/s0300-8932(00)75066-4 · Cited by 45
Critical review of electrocardiography measurement systems and technology
Kalra, A. M., Lowe, A., & Al‐Jumaily, A. M. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aaf2b7 · Cited by 35
Flethøj, M., Kanters, J. K., Pedersen, P. J., Haugaard, M. M., Carstensen, H., Olsen, L. H., & Buhl, R. (2016) · BMC Veterinary Research · doi:10.1186/s12917-016-0894-2 · Cited by 30
“Many arrhythmias are paroxysmal, and comprehensive evaluation of their frequency therefore requires longterm ECG recording for 24 h or more [14].”
BackgroundDizziness in primary care patients
Warner, E. A., Wallach, P. M., Adelman, H. M., & Sahlin-Hughes, K. (1992) · Journal of General Internal Medicine · doi:10.1007/bf02599167 · Cited by 29
Krahn, A. D., Klein, G. J., Yee, R. K., & Skanes, A. C. (2004) · Clinical Autonomic Research · doi:10.1007/s10286-004-1008-y · Cited by 27
VALUE AND LIMITATIONS OF NONINVASIVE ASSESSMENT OF SYNCOPE
Hammill, S. C. (1997) · Cardiology Clinics · doi:10.1016/s0733-8651(05)70330-1 · Cited by 28
Ruwald, M. H., & Zaręba, W. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2013.08.007 · Cited by 23
“On the contrary, they found that 3 days of Holter monitoring did not provide significant additional diagnostic information in these patients.(24,25) Kühne et al.”
BackgroundGuía de práctica clínica para el diagnóstico y manejo del síncope (versión 2009)
Moya‐Mitjans, À., Sutton, R., Ammirati, F., Blanc, J., Brignole, M., Dahm, J. B., Deharo, J., Gajek, J. J., Gjesdal, K., Krahn, A. D., et al. (2009) · Revista Española de Cardiología · doi:10.1016/s0300-8932(09)73132-x · Cited by 29
Huff, J. S., Decker, W. W., Quinn, J., Perron, A. D., Napoli, A. M., Peeters, S., & Jagoda, A. S. (2007) · Journal of Emergency Nursing · doi:10.1016/j.jen.2007.04.009 · Cited by 24
Vardas, P. E., Cowie, M., Dagres, N., Asvestas, D., Tzeis, S. E., Vardas, E. P., Hindricks, G., & Camm, A. J. (2019) · EP Europace · doi:10.1093/europace/euz249 · Cited by 23
Emerging Role of Digital Technology and Remote Monitoring in the Care of Cardiac Patients
Banchs, J. E., & Scher, D. M. (2015) · Medical Clinics of North America · doi:10.1016/j.mcna.2015.02.013 · Cited by 22
Syncope: Review of Monitoring Modalities
Krahn, A. D., Subbiah, R. N., Gula, L. J., Klein, G. J., Skanes, A. C., & Yee, R. K. (2008) · Current Cardiology Reviews · doi:10.2174/157340308783565447 · Cited by 22
“One study has investigated an extended duration of ambulatory Holter monitoring of 72 hours [13].”
BackgroundBandorski, D., Erkapic, D., Stempfl, J., Höltgen, R., Grünig, E., Schmitt, J., Chasan, R., Grimminger, J., Neumann, T., Hamm, C. W., et al. (2015) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-015-0364-8 · Cited by 19
Syncope: Current diagnosis and treatment
Henderson, M. C., & Prabhu, S. D. (1997) · Current Problems in Cardiology · doi:10.1016/s0146-2806(97)80008-4 · Cited by 22
Cardiac Monitoring in Patients with Syncope: Making that Elusive Diagnosis
Subbiah, R., Chia, P.-L., Gula, L., Klein, G., Skanes, A., Yee, R., & Krahn, A. (2014) · Current Cardiology Reviews · doi:10.2174/1573403x10666140214120056 · Cited by 19
“In a study which evaluated extension of Holter monitoring duration to 72 h [13], there was an increase in the number of asymptomatic arrhythmias detected, but not the overall diagnostic yield.”
Episodic collapse in the horse
Lyle, C. H., & Keen, J. (2010) · Equine Veterinary Education · doi:10.1111/j.2042-3292.2010.00136.x · Cited by 23
Selecting Appropriate Diagnostic Tools for Evaluating the Patient With Syncope/Collapse
Krahn, A. D., Andrade, J. G., & Deyell, M. W. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.11.003 · Cited by 19
Prognostic Relevance of Nonsustained Ventricular Tachycardia in Patients with Pulmonary Hypertension
Bandorski, D., Bogossian, H., Stempfl, J., Seeger, W., Hecker, M., Ghofrani, H. A., Hoeltgen, R., & Gall, H. J. (2016) · BioMed Research International · doi:10.1155/2016/1327265 · Cited by 19
Moya‐Mitjans, À., Rivas‐Gándara, N., Sarrias, A., Pérez‐Rodon, J., & Roca‐Luque, I. (2012) · Revista Española de Cardiología · doi:10.1016/j.recesp.2012.03.005 · Cited by 24
External Cardiac Loop Recorders: Functionalities, Diagnostic Efficacy, Challenges and Opportunities
Rajanna, R. R., Sriraam, N., Prakash, V. S. R., Vittal, P. R., Arun, U., & Sahoo, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3055219 · Cited by 17
Recognizing Cardiac Syncope in Patients Presenting to the Emergency Department with Trauma
Bhat, P. K., Pantham, G., Laskey, S. L., Como, J. J., & ROSENBAUM, D. S. (2013) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2013.04.064 · Cited by 20
Holter Monitoring in Syncope: Diagnostic Yield in Octogenarians
Kühne, M., Schaer, B. A., Sticherling, C., & Osswald, S. (2011) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2011.03486.x · Cited by 18
“Another study of three serial 24-hour Holter recordings had similar findings.(12) In a study comparing loop recorders for 30 days with 48-hour Holter monitoring in younger adults with syncope or near syncope, the overall probability of obtaining a symptom-rhythm correlation was 56% in the loop recorder group and signi…”
ResultDavison, J. M., Brady, S., & Kenny, R. A. (2005) · Age and Ageing · doi:10.1093/ageing/afi108 · Cited by 18
“Electrocardiographic abnormalities identified were categorised using published criteria [12].”
MethodHadjikoutis, S., O’Callaghan, P., & Smith, P. E. M. (2004) · Seizure · doi:10.1016/j.seizure.2003.12.011 · Cited by 19
Khadilkar, S., Yadav, R. S., & Jagiasi, K. (2013) · Neurology India · doi:10.4103/0028-3886.115060 · Cited by 19
Willcox, M. E., Compton, S. J., & Bardy, G. H. (2021) · Heart Rhythm O2 · doi:10.1016/j.hroo.2021.09.008 · Cited by 14
Naccarelli, G. V. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00737.x · Cited by 13
Investigating syncope: a review
Gould, P. A., Krahn, A. D., Klein, G. J., Yee, R. K., Skanes, A. C., & Gula, L. J. (2005) · Current Opinion in Internal Medicine · doi:10.1097/01.hco.0000198986.16626.86 · Cited by 14
Ikeda, T., Ashihara, T., Iwasaki, Y., Ono, M., Kagiyama, N., Kimura, T., KUSANO, K. F., Kohno, R., Saku, K., Sasano, T., et al. (2025) · Circulation Journal · doi:10.1253/circj.cj-24-0960 · Cited by 12
ARGONAUT: An Inclusive Design Process for Wearable Health Monitoring Systems
Schauss, G., Arquilla, K. S., & Anderson, A. P. (2022) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3491102.3517590 · Cited by 14
“While effective, the Holter monitor has seen minimal improvement in functional and aesthetic design, which results in a bulky and uncomfortable device, missing the mark of “social wearability” [9, 10, 19, 21, 53].”
BackgroundMethodFalling Down and Falling Out: Management and Outcome Analysis
Omert, L., Zakhary, S., Wilson, R. W., Diminno, C., & Rodríguez, A. (2004) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000108635.22803.cb · Cited by 13
EVALUATION OF THE PATIENT WITH SYNCOPE: AN EVIDENCE BASED APPROACH
Meyer, M., & Handler, J. A. (1999) · Emergency Medicine Clinics of North America · doi:10.1016/s0733-8627(05)70052-3 · Cited by 13
Chang-Sing, P., & Peter, C. T. (1991) · Cardiology Clinics · doi:10.1016/s0733-8651(18)30269-8 · Cited by 12
Holter monitoring in dogs: 24 h vs. 48 h
Mavropoulou, A., Oliveira, P., & Willis, R. (2021) · The Veterinary Journal · doi:10.1016/j.tvjl.2021.105628 · Cited by 11
Bulková, V. (2021) · Vnitřní lékařství · doi:10.36290/vnl.2021.002 · Cited by 11
“Výtěžnost EKG Holteru se v neselektované populaci se synkopou pohybovala pod 4 % (8, 9).”
BackgroundManaging the military patient with syncope
Parsons, I., Cox, A., Mollan, I. A., & Boos, C. J. (2015) · Journal of the Royal Army Medical Corps · doi:10.1136/jramc-2015-000493 · Cited by 11
Frequency of Serious Arrhythmias Detected With Ambulatory Cardiac Telemetry
Kadish, A. H., Reiffel, J. A., Clauser, J., Prater, S. P., Menard, M., & Kopelman, H. A. (2010) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.12.047 · Cited by 10
Conn, N. J., Schwarz, K. Q., & Borkholder, D. A. (2018) · JMIR mhealth and uhealth · doi:10.2196/mhealth.9604 · Cited by 11
Holter monitoring: are two days better than one?
McClennen, S., ZIMETBAUM, P. J., Ho, K. K. L., & Goldberger, A. L. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01017-1 · Cited by 11
Metadata
- Authors
- Bass, E. B.
- Corresponding author
- Bass, Eric B.
- ORCID
- Bass, Eric B.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 1990-05-01
- Volume
- 150
- Issue
- 5
- Pages
- 1073
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W4247144249
- Cited by
- 156
- References
- 0
- Citations by year
- 2026: 1 · 2025: 9 · 2024: 3 · 2022: 6 · 2021: 5 · 2020: 3 · 2019: 5 · 2018: 10 · 2017: 4 · 2016: 3 · 2015: 9 · 2014: 7 · 2013: 10 · 2012: 5
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Archives of Internal Medicine (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (1RO1 HL36735, K04 HL01899)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- Holter monitoring, syncope, monitoring duration, cardiac arrhythmias, syncope etiology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.