The Duration of Holter Monitoring in Patients With Syncope: Is 24 Hours Enough?
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
To determine the incremental yield of ambulatory monitoring in the evaluation of syncope, three serial 24-hour Holter recordings were obtained in a consecutive series of 95 patients with syncope, the cause of which was not explained by history, physical examination, or 12-lead electrocardiogram. The mean age of patients was 61 years and 41% were men. Major electrocardiographic abnormalities were found in 26 patients (27%), including unsustained ventricular tachycardia (19 patients), pauses of at least 2 seconds (8 patients), profound bradycardia (1 patient), and complete heart block (1 patient). The first 24-hour Holter recording had at least one major abnormality in 14 patients (15%) (95% confidence interval, 8.3% to 23.4%). Of the 81 patients without a major abnormality on the first Holter recording, the second Holter recording had major abnormalities in 9 (11%) (95% confidence interval, 5.1% to 20.0%). Of the 72 patients without a major abnormality on the first two Holter recordings, only 3 patients (4.2%) had a major abnormality on the third Holter recording (95% confidence interval, 0.8% to 11.7%). Four factors were significantly associated with an increased likelihood of a major abnormality on 72 hours of monitoring: age above 65 years (relative risk, 2.2), male gender (relative risk, 2.0), history of heart disease (relative risk, 2.2), and an initial nonsinus rhythm (relative risk, 3.5). These results suggest that 24 hours of Holter monitoring is not enough to identify…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Holter monitoring and external loop recorders serve as main noninvasive monitoring strategies, but the diagnostic yield is low, especially in cases of infrequent symptoms [5,7].”
From Diagnostic Yield and Clinical Implications of Implantable Loop Recorders in Patients with Syncope in Germany: A National Database Analysis (2024) · cites this paper as [7]
In the citing paper
“In another study, the median time for recording a symptom-rhythm correlation was 16 days for patients assigned a loop recorder as their first diagnostic strategy and symptom-rhythm correlation was obtained in 87% of patients by 1 month of monitoring (Bass et al., 1990).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Bass et al., 1990
In the citing paper
“In 15% of patients, symptoms were not associated with arrhythmia. 161”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [161]
Citations
Cites
The publisher hasn’t deposited this paper’s reference list.
Cited by
Items 101–200 of 202
Value of Ambulatory Electrocardiographic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.004 · Cited by 11
Clinical characteristics of unexplained syncope and their relationship to tilt table test outcomes
Graham, L. A., & Kenny, R. A. (2002) · Clinical Autonomic Research · doi:10.1007/s102860200026 · Cited by 9
“Since the advent of tilt table testing for the diagnosis of vasovagal syncope in 1986 [9], few studies have compared test outcome and clinical characteristics.”
BackgroundCNN-based Two Step R Peak Detection Method: Combining Segmentation and Regression
Jang, J., Park, S., Kim, J.-K., An, J., & Jung, S. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871227 · Cited by 8
Recommendations of the Brazilian Society of Cardiac Arrhythmias for Holter Monitoring Services
Filho, A. L., Cintra, F. D., Lorga, A. M., Grupi, C., Pinho, C., Moreira, D. A. R., Filho, D. C. S., de Brito, F. S., Kruse, J. C. L., & Neto, J. S. (2013) · Arquivos Brasileiros de Cardiologia · doi:10.5935/abc.20130164 · Cited by 10
Real time ECG R-peak detection by extremum sampling
Reklewski, W., Heryan, K., Miśkowicz, M., & Augustyniak, P. (2020) · International Conference on Event-based Control, Communication, and Signal Processing · doi:10.1109/ebccsp51266.2020.9291358 · Cited by 8
“in syncope [2], rarely occurring arrhythmia [3], cardiomyopathy [4]).”
BackgroundUngar, A., & Rafanelli, M. (2018) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2018.02.007 · Cited by 8
Holter Monitoring vs Tilt Testing in the Investigation of Suspected Vasovagal Syncope
Fitchet, A., Stirling, M. L., BURNETT, G., Goode, G., Garratt, C. J., & Fitzpatrick, A. P. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.t01-1-00221.x · Cited by 8
Krahn, A. D., Renner, S., Klein, G. J., Yee, R. K., Skanes, A. C., & Evans, E. M. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00400.x · Cited by 7
Syncope: risk stratification and clinical decision making.
Peeters, S., Hoek, A. E., Mollink, S. M., & Huff, J. S. (2014) · PubMed · Cited by 9
Arnold, R. J. G., & Layton, A. J. (2015) · Journal of health economics and outcomes research · doi:10.36469/9897 · Cited by 7
33 Ambulatory Electrocardiogram Monitoring
Hombach, V. (2010) · Springer eBooks · doi:10.1007/978-1-84882-046-3_33 · Cited by 7
Leng, T., Aldalati, A., & Homme, J. L. (2025) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2025.03.032 · Cited by 6
Symptomatic postural hypotension in diabetes: aetiology and management
Winkler, A. S., & Bosman, D. (2003) · Practical Diabetes · doi:10.1002/pdi.507 · Cited by 6
Martow, E., & Sandhu, R. K. (2019) · Medical Clinics of North America · doi:10.1016/j.mcna.2019.05.002 · Cited by 6
Evaluation of syncope: an overview.
Gupta, A. K., Maheshwari, A., & Lokhandwala, Y. Y. (2001) · PubMed Central · Cited by 6
Kim, S.-B., Choi, W., Liu, W., Lee, N., Shin, T., & Lee, Y. (2014) · Journal of Acupuncture and Meridian Studies · doi:10.1016/j.jams.2014.04.001 · Cited by 5
“One is performed on the basis of 24 hour Holter recordings (long-term recordings) [37,38], and the other method needed a shorter period ranging from 0.5 minutes to 5 minutes for collecting data from 200 heartbeats to 500 heartbeats (short-term recordings).”
InfluentialThe Role of the Syncope Management Unit
Kenny, R. A., Rice, C. P., & Byrne, L. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.016 · Cited by 5
Mueller-Leisse, J., Hillmann, H. A. K., Iserloh, L., Fruehauf, B., & Duncker, D. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13061564 · Cited by 4
“Holter monitoring and external loop recorders serve as main noninvasive monitoring strategies, but the diagnostic yield is low, especially in cases of infrequent symptoms [5,7].”
BackgroundDuvillier, L., Demolder, A., Renterghem, S. V., Mey, C. D., West, F., & Pooter, J. D. (2024) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16420 · Cited by 5
“9 12 ILRs allow long ‐ term surveillance of a single ‐ lead electrocardiogram (ECG) and have been shown to be effective tools in detecting clinically relevant arrhythmias, 13 – 17 thereby leading to an earlier diagnosis.”
Bouzas‐Mosquera, A., Sánchez‐Fernández, G., Barbeito‐Caamaño, C., Broullón, F. J., Martínez, D., Yáñez, J. C., Álvarez‐García, N., & Vázquez‐Rodríguez, J. M. (2015) · Journal of the American Geriatrics Society · doi:10.1111/jgs.13846 · Cited by 4
Clinical experience in extended cardiac monitoring with the SEEQ™ satellite wireless system
Vanegas, D. I., Valderrama-Barbosa, Z., & Ibatá, L. (2018) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2017.09.008 · Cited by 5
Brandes, A., & Bethge, K.-P. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0010-9 · Cited by 10
Ikeda, T., Ashihara, T., Iwasaki, Y., Ono, M., Kagiyama, N., Kimura, T., KUSANO, K. F., Kohno, R., Saku, K., Sasano, T., et al. (2025) · Journal of Arrhythmia · doi:10.1002/joa3.70059 · Cited by 3
Multiplierless QRS detection algorithm for mobile ECG monitoring based on approximate computing
Reklewski, W., Heryan, K., Augustyniak, P., & Miśkowicz, M. (2025) · Measurement · doi:10.1016/j.measurement.2025.116969 · Cited by 4
Implantable Cardiac Rhythm and Hemodynamic Monitors
Daly, M. G., Melton, I., & Crozier, I. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-37804-8.00025-0 · Cited by 4
Vanegas, D. I., Valderrama-Barbosa, Z., & Ibatá, L. (2018) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2017.09.003 · Cited by 3
Choi, Y. Y., Choi, J., Kim, Y. G., Min, K., Roh, S., Shim, J., Choi, J. S., & Kim, Y. (2022) · International Journal of Arrhythmia · doi:10.1186/s42444-022-00068-w · Cited by 4
The Role of the Syncope Management Unit
Kenny, R. A., Rice, C. P., & Byrne, L. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.08.013 · Cited by 3
Appropriateness of ECG Holter requests in an outpatient service: a prospective study
Piccirilli, S., Gallagher, M. M., Vellini, M., Padula, M., Voumvourakis, A., Santini, L., Magliano, G., & Romeo, F. (2007) · Journal of Cardiovascular Medicine · doi:10.2459/01.jcm.0000278449.96988.82 · Cited by 3
Electrocardiology, N., Kadish, A. H., Buxton, A. E., Winters, W. L., & Boone, A. W. (2001) · Cited by 3
Subbiah, R. N., Gula, L. J., Klein, G. J., Skanes, A. C., Yee, R. K., & Krahn, A. D. (2008) · Springer eBooks · doi:10.1007/978-1-84628-854-8_23 · Cited by 4
Roblot, P., Chaille, D., Maréchaud, R., & Becq-giraudon, B. (1993) · La Revue de Médecine Interne · doi:10.1016/s0248-8663(05)81169-5 · Cited by 3
Indikationen Zur Loop-Rekorder-Implantation Bei Synkope
Schuchert, A. (2018) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-018-0571-1 · Cited by 2
Yuniadi, Y., Hanafy, D. A., Raharjo, S. B., & Hermanto, D. Y. (2025) · Archives of Medical Research · doi:10.1016/j.arcmed.2025.103257 · Cited by 2
Pandiyan, M., Mani, G., Jerome, J., & Natarajan, S. (2015) · IFIP/IEEE International Conference on Very Large Scale Integration · doi:10.1109/vlsi-soc.2015.7314408 · Cited by 2
Syncope/Presyncope in the Competitive Athlete
Asplund, C. A., O’Connor, F. G., & Levine, B. D. (2010) · Springer eBooks · doi:10.1007/978-0-387-92775-6_9 · Cited by 2
Evaluation of Patients with Palpitations: Cardiac Event Recorder Versus 48‐hour Holter Monitoring
Makowska, E., Szymot, J., Soszyriska, M., & Kułakowski, P. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00068.x · Cited by 3
An introduction to ambulatory electrocardiography
Richley, D. (2010) · British Journal of Cardiac Nursing · doi:10.12968/bjca.2010.5.1.46025 · Cited by 2
Brunetti, N. D., D’Arienzo, G., Tiscia, G., Pellegrino, P. L., Gennaro, L. D., & Biase, M. D. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.02.055 · Cited by 3
Uznańska‐Loch, B., Trzos, E., Wierzbowska-Drabik, K. A., Śmigielski, J., Rechciński, T., Cieślik‐Guerra, U., Kasprzak, J. D., & Kurpesa, M. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12012 · Cited by 3
Observation Medicine and Clinical Decision Units
Mahadevan, M., & Graff, L. (2010) · Elsevier eBooks · doi:10.1016/b978-0-323-05472-0.00196-1 · Cited by 2
Externe und implantierbare Ereignisrekorder zum Event-Recording in der Synkopendiagnostik
Seidl, K., Vater, M., & Senges, J. (2002) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-002-0340-y · Cited by 2
“(18) berichtete über die Detektion von Indikatorarrhythmien im 24-Stunden-EKG bei 15% der Patienten, durch ein 48-Stunden-Langzeit-EKG erhöht sich der Anteil der Indikatorarrhythmien um zusätzliche 11%, durch eine 72-Stunden-LangzeitEKG-Aufzeichnung steigt die diagnostische Wertigkeit nur noch”
BackgroundHussein, A. A., & SALIARIS, A. P. (2012) · Cardiology Clinics · doi:10.1016/j.ccl.2012.07.014 · Cited by 2
Setting up a falls and syncope service for the elderly
O’Shea, D. (2002) · Clinics in Geriatric Medicine · doi:10.1016/s0749-0690(02)00009-5 · Cited by 2
Erregungsbildungs- und Erregungsleitungsstörungen
Kalusche, D., & Csapo, G. (1996) · Springer eBooks · doi:10.1007/978-3-642-97605-6_25 · Cited by 2
Syncope of Unknown Origin: First Head-Up Tilt Test or Electrophysiologic Study?
Alboni, P., Raviele, A., Vecchio, C., Andrioli, G., Brignole, M., Menozzi, C., Piccolo, E., & Proclemer, A. (1996) · Springer eBooks · doi:10.1007/978-88-470-2223-2_19 · Cited by 2
Synkopendiagnostik: wann ambulant, wann stationär?
Schuchert, A., & Wille, E. (2008) · Herz · doi:10.1007/s00059-008-3145-x · Cited by 2
“In mehreren Studien mit einer Aufzeichnungsdauer von > 12 h betrug die Symptom-Rhythmus-Korrelation 19% [4].”
BackgroundWeir, C. J., Reed, M. J., Simpson, K., Lang, C., Grubb, N. R., & Gray, A. J. (2020) · doi:10.17504/protocols.io.bgtfjwjn · Cited by 2
Sriram, S., Polachan, K., & Sen, S. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.06.13.495999 · Cited by 2
Ikeda, T., Ashihara, T., Iwasaki, Y., Ono, M., Kagiyama, N., Kimura, T., KUSANO, K. F., Kohno, R., Saku, K., Sasano, T., et al. (2024) · Japanese Journal of Electrocardiology · doi:10.5105/jse.44.275 · Cited by 1
Approach to Patients with Syncope in Emergeny Department - An Evidence-Based Review
Çiftci, O., Kavalcı, C., & Durukan, P. (2013) · Eurasian Journal of Emergency Medicine · doi:10.5152/jaem.2013.040 · Cited by 3
“(16) made a retrospective analysis of short-term (7-day) adverse cardiac events (cardiac death or hospitalization) in 39,943 admissions for syncope in 35,330 patients and reported that 3% of patients experienced adverse events, the positive predictors of which were age ≥60 years, male gender, congestive heart failure,…”
BackgroundChu, C., Lee, E., Leung, C., & Lit, A. (2010) · Hong Kong Journal of Emergency Medicine · doi:10.1177/102490791001700402 · Cited by 1
Schuchert, A. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0011-8 · Cited by 3
“In einer Metaanalyse zur Synkopendiagnostik war das Langzeit-EKG über 24 bis 72 Stunden nur bei 4% der Patienten diagnostisch hilfreich, da in diesem kurzen Zeitraum selten eine weitere Episode auftrat [3].”
BackgroundDiagnostic approaches to syncope in Internal Medicine Departments and their effect on mortality
Galron, E., Kehat, O., Weiss‐Meilik, A., Furlan, R., & Jacob, G. (2022) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2022.05.015 · Cited by 1
Value of Ambulatory Electrocardiographic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.08.009 · Cited by 1
CURRENT METHODS OF OUTPATIENT ELECTROCARDIOGRAPHIC MONITORING. CLINICAL ASPECTS
Pervova, E. V. (2017) · The Clinician · doi:10.17650/1818-8338-2017-11-2-58-73 · Cited by 4
Holter Monitors, Event Monitors, and Implantable Loop Recorders
Seutter, R., & Levine, G. N. (2009) · Elsevier eBooks · doi:10.1016/b978-0-323-04525-4.00005-8 · Cited by 1
Yang, S., & ZIMETBAUM, P. J. (2020) · Springer eBooks · doi:10.1007/978-3-030-47868-1_26 · Cited by 1
The Diagnosis of Syncope in the Elderly
Frazier, H. S. (1993) · International Journal of Technology Assessment in Health Care · doi:10.1017/s026646230000307x · Cited by 2
“syncope was not discovered through a history, physical examination, and routine ECG (2).”
Backgroundthe Society of PhySicianS of hong Kong
Wai, K., & Keung, L. W. (2012) · Cited by 1
Lipsitz, L. A., & Grubb, B. P. (2005) · Wiley eBooks · doi:10.1002/9780470994801.ch18 · Cited by 3
Kapoor, W. N. (2006) · Springer eBooks · doi:10.1007/0-387-22621-4_65 · Cited by 1
Diagnosis of Arrhythmias with Non-invasive Tools
Sullivan, R. M., Li, W. W., Kendig, A. C., & Olshansky, B. (2010) · Humana Press eBooks · doi:10.1007/978-1-60761-161-5_5 · Cited by 4
Implantable Loop Recorder and Syncope-Rhythm Correlation
Maniotis, C. D., Manolis, A. G., Dimitriou, P., Kouvelas, K., & Kyriakides, Z. S. (2014) · Hospital chronicles/Hospital Chronicles
[Syncope in the elderly: findings of diagnostic complementary tests in a University Hospital].
Asensio-Lafuente, E., Orea‐Tejeda, A., Castillo‐Martínez, L., Fraga-Sastrías, J. M., Colin-Ramírez, E., & Prieto‐Sagredo, J. (2009) · PubMed · Cited by 1
Syncope: An Uncommon Presentation of Ischemic Cardiomyopathy
Al‐Zaiti, S. S., Khasawneh, M. K., & Carey, M. G. (2011) · The Journal for Nurse Practitioners · doi:10.1016/j.nurpra.2011.01.006
Stellenwert des implantierbaren Looprekorders im Rahmen der Diagnostik von Synkopen
Ehlers, C., Brüggemann, T., Wiedemann, M., & Andresen, D. (2000) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s003990070006
Beleslin, B., Deljanin, M., Kanjuh, V., Parapid, B. J., Giga, V. L., Prostran, M. S., Angelkov, L., Balinovac, J., Bikicki, M., Ambrosio, G., et al. (2013)
Długoterminowe monitorowanie holterowskie — rodzaje i znaczenie kliniczne
Krawczyńska, A., Średniawa, B., Cebula, S., Musialik-Lydka, A., Kowalski, O., Lenarczyk, R., Woźniak, A., Tabor, K., & Kalarus, Z. F. (2010) · Folia Cardiologica
Benditt, D. G., Blanc, F. J.-J., Brignole, F. M., & DScMed, F. R. S. (2006) · Wiley eBooks · doi:10.1002/9781444312812.refs
Evaluation of Syncope in the Elderly Patient
Stugensky, K. M., Neuberg, G. W., & Maurer, M. S. (2008) · Fundamental and clinical cardiology · doi:10.3109/9781420061710.026
Value of Ambulatory Electrocardiogra phic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2013)
Synkopenabklärung: Sinn oder Unsinn?
Hubner, D., & Eber, B. (2000) · Journal für Kardiologie (Krause & Pachernegg GmbH)
Holter Monitors, Event Monitors, Ambulatory Monitors, and Implantable Loop Recorders
Mathur, N., Seutter, R., & Levine, G. N. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-4815-0.00008-8
Long-term electrocardiographic monitoring: time to reconsider our standards
Arribas, J. M., & Bertomeu‐González, V. (2019) · Current Medical Research and Opinion · doi:10.1080/03007995.2019.1636544
Use of Implantable Monitors for Arrhythmia Detection
Tomala, J., & Piorkowski, C. (2019) · Springer eBooks · doi:10.1007/978-3-030-22882-8_9
Krahn, A. D., Yee, R. K., Skanes, A. C., & Klein, G. J. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-2856-5.00064-9
Value of a Novel 7-Day Patch Electrocardiography on Monitoring Cardiac Arrhythmias
Zhang, X., Zhao, Y., Yan, J., Chen, X., Xiong, Y., Zheng, P. P., Xing, J., Chen, D., Weng, J., Zhang, W., et al. (2020)
A Point-of-Care Algorithm to Guide Proper Device Selection for Ambulatory Electrocardiography
Farasat, M., Sánchez, J. M., West, J. J., Burke, J. M., Prouse, A., Gore, M. O., Salame, G., Keach, J. W., Trent, S. A., Haigney, M. C., et al. (2021) · Critical Pathways in Cardiology A Journal of Evidence-Based Medicine · doi:10.1097/hpc.0000000000000259
the Society of PhySicianS of hong Kong
Hin, C. T., & Kuen, T. K. (2010)
Schwindel und Synkope: Klinische Fallbeispiele
Athanasiadis, A., & Sechtem, U. P. (2014) · Herz · doi:10.1007/s00059-014-4100-7
Ambulatory Electrocardiogram Monitoring
Hombach, V. (2011) · Springer eBooks · doi:10.1007/978-0-85729-880-5_1
Kapoor, W. N. (1997) · Springer eBooks · doi:10.1007/978-1-4757-2705-0_49
Fröhlig, G. (2014) · Springer eBooks · doi:10.1007/978-3-642-54676-1_486-1
Yang, S., & ZIMETBAUM, P. J. (2022) · Springer eBooks · doi:10.1007/978-3-030-88953-1_4
Gould, P. A., Klein, G. J., Yee, R., Skanes, A. C., Gula, L. J., & Krahn, A. D. (2008) · Handbook of clinical neurology · doi:10.1016/s0072-9752(07)01714-9
Grossman, S. A. (2011) · Wiley eBooks · doi:10.1002/9781119959809.ch13
Subbiah, R. N., Chia, P., Leong‐Sit, P., Gula, L. J., Skanes, A. C., Yee, R. K., Klein, G. J., & Krahn, A. D. (2013) · Springer eBooks · doi:10.1007/978-1-4471-4978-1_15
Moya‐Mitjans, À., Rivas‐Gándara, N., Sarrias, A., Pérez‐Rodon, J., & Roca‐Luque, I. (2012) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2012.03.004 · Cited by 2
Gómez, J. J. G., Hernández, A. H., & Zapater, E. L.-Z. (2013) · Medicine - Programa de Formación Médica Continuada Acreditado · doi:10.1016/s0304-5412(13)70619-x
Fits, faints, funny turns, and falls in the differential diagnosis of the dizzy patient
Tarnutzer, A. A., & Newman‐Toker, D. E. (2025) · Oxford University Press eBooks · doi:10.1093/med/9780198834380.003.0027
Homme, J. L., Kranz, L. A., House, M., & Greenmyer, J. R. (2025) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2025.04.012
“Blacked Out and Slumped Down”
Wijdicks, E. F. M. (2025) · Oxford University Press eBooks · doi:10.1093/med/9780197544976.003.0007
Đặc điểm điện tâm đồ ghi liên tục 24 giờ ở bệnh nhân ngất
Lê, T. H., Trần, S. G., & Đinh, H. L. (2025) · Tạp chí Tim Mạch Học Việt Nam · doi:10.58354/jvc.113.2025.874
Incidence and Predictors of Symptom-Arrhythmia Association During Outpatient Holter Monitoring
Saraiya, A., Corsi, D. R., Farhan, S., Hazlewood, C., Qiu, G., & Pavri, B. B. (2025) · Cureus · doi:10.7759/cureus.96201
Benabbas, R., Zehtabchi, S., Wakai, A., Allen, R. W., deSouza, I. S., Richards, R. J., Curley, D., Dunne, E., & Sinert, R. H. (2025) · Academic Emergency Medicine · doi:10.1111/acem.70175
The Diagnosis of Cardiac Arrhythmias
Richardson, A., & ZIMETBAUM, P. J. (2002) · Contemporary cardiology · doi:10.1007/978-1-59259-090-2_2
Extended ECG monitoring in the diagnosis of syncope
Tyuryupov, M. S., Kripak, A. O., Kutelev, G. G., Asyamov, K. V., & Shershneva, A. A. (2026) · Russian Military Medical Academy Reports · doi:10.17816/rmmar677272
“Так , признано, что «золотым стандартом» диагностики нарушений ритма и проводимости в настоящее время является Холтеровское мониторирование ЭКГ (ХМ-ЭКГ) [14–16].”
Evolutionary Synthesis of QRS Detection Algorithms for Wearable ECG-Based Heartbeat Classification
Reklewski, W., Potoczny, J., & Augustyniak, P. (2026) · Electronics · doi:10.3390/electronics15184269
Metadata
- Authors
- Bass, E. B.
- Corresponding author
- Bass, Eric B.
- ORCID
- Bass, Eric B.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 1990-05-01
- Volume
- 150
- Issue
- 5
- Pages
- 1073
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W4247144249
- Cited by
- 156
- References
- 0
- Citations by year
- 2026: 1 · 2025: 9 · 2024: 3 · 2022: 6 · 2021: 5 · 2020: 3 · 2019: 5 · 2018: 10 · 2017: 4 · 2016: 3 · 2015: 9 · 2014: 7 · 2013: 10 · 2012: 5
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Archives of Internal Medicine (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (1RO1 HL36735, K04 HL01899)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- Holter monitoring, syncope, monitoring duration, cardiac arrhythmias, syncope etiology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.