Medical Device Recalls and the FDA Approval Process

Zuckerman, Diana M., Brown, Paul, Nissen, Steven E.·2011·Archives of Internal Medicine

Abstract

BACKGROUND: Unlike prescription drugs, medical devices are reviewed by the US Food and Drug Administration (FDA) using 2 alternative regulatory standards: (1) premarket approval (PMA), which requires clinical testing and inspections; or (2) the 510(k) process, which requires that the device be similar to a device already marketed (predicate device). The second standard is intended for devices that the FDA deems to involve low or moderate risk. METHODS: We analyzed the FDA's high-risk List of Device Recalls from 2005 through 2009. Using FDA data, we determined whether the recalled devices were approved by the more rigorous (PMA) process, the 510(k) process, or were exempt from FDA review. RESULTS: There were 113 recalls from 2005 through 2009 that the FDA determined could cause serious health problems or death. Only 21 of the 113 devices had been approved through the PMA process (19%). Eighty were cleared through the 510(k) process (71%), and an additional 8 were exempt from any FDA regulation (7%). Cardiovascular devices comprised the largest recall category, with 35 of the high-risk recalls (31%); two-thirds were cleared by the 510(k) process (66%; n = 23). Fifty-one percent of the high-risk recalls were in 5 other device categories: general hospital, anesthesiology, clinical chemistry, neurology, or ophthalmology. CONCLUSIONS: Most medical devices recalled for life-threatening or very serious hazards were originally cleared for market using the less stringent 510(k) process or were considered so low risk that they were exempt from review (78%). These findings suggest that reform of the regulatory process is needed to ensure the safety of medical devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archinternmed.2011.30

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 265

Metadata

Authors
Zuckerman, D. M., Brown, P., & Nissen, S. E.
Venue
Archives of Internal Medicine
Published
2011-06-13
Volume
171
Issue
11
Pages
1006-11
ISSN
0003-9926 (ISSN-L)
OpenAlex
W2067869350
Cited by
265
References
0
FWCI
33.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Medical Device Recalls and the FDA Approval Process. https://app.cochat.ai/papers/10.1001/archinternmed.2011.30
The paper
Zuckerman, D. M., Brown, P., & Nissen, S. E. (2011). Medical Device Recalls and the FDA Approval Process. Archives of Internal Medicine. https://doi.org/10.1001/archinternmed.2011.30

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.