The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Detects Cortical and Juxtacortical Multiple Sclerosis Lesions
Abstract
BACKGROUND: Autopsy studies showed cortical and juxtacortical multiple sclerosis (MS) plaques. Fluid-attenuated inversion recovery (FLAIR) is an advanced magnetic resonance imaging sequence that reveals tissue T2 prolongation with cerebrospinal fluid suppression, allowing detection of superficial brain lesions. OBJECTIVES: To assess FLAIR, T1-weighted, and T2-weighted images for detecting lesions in or near the cerebral cortex in patients with MS and to explore the relation between cortical lesions and cortical atrophy. DESIGN, SETTING, AND PATIENTS: Cross-sectional study in a university MS clinic of 84 patients with MS and 66 age-matched healthy controls receiving 1.5-T fast FLAIR, T2-weighted, and T1-weighted images. MAIN OUTCOME MEASURES: Regional cortical atrophy was rated vs controls. Cortical and juxtacortical lesions were ovoid hyperintensities involving the cortex and/or gray-white junction. RESULTS: A total of 810 cortical and juxtacortical lesions were seen by FLAIR in patients (mean, 9.6 per patient), most commonly in the superior frontal lobe. Cortical and juxtacortical lesions were identified in 72 patients and 6 controls. Fourteen percent of cortical and juxtacortical lesions were seen on T1-weighted images and 26% were seen on T2-weighted images. More cortical and juxtacortical lesions were present in secondary progressive disease than relapsing-remitting disease. The total number of cortical and juxtacortical lesions correlated significantly with disease duration and the regional number correlated with the degree of regional atrophy. After taking into account noncortical (white matter) lesions, only the cortical and juxtacortical lesion count predicted atrophy in that region. CONCLUSIONS: FLAIR can detect many cortical and juxtacortical lesions in MS, which were appreciated previously in autopsy studies but usually missed by magnetic resonance imaging during life. Cortical and juxtacortical plaque formation may contribute to cortical atrophy in MS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Axonal transection in the lesions of multiple sclerosis
Trapp, B. D., Peterson, J., Ransohoff, R. M., Rudick, R., Mörk, S., & Bö, L. (1998) · New England Journal of Medicine · doi:10.1056/nejm199801293380502 · Cited by 4,029
Subgenual prefrontal cortex abnormalities in mood disorders
Drevets, W. C., Price, J. L., Simpson, J. R., Todd, R. D., Reich, T., Vannier, M., & Raichle, M. E. (1997) · Nature · doi:10.1038/386824a0 · Cited by 2,693
Fatigue in multiple sclerosis and its relationship to depression and neurologic disability
Bakshi, R., Shaikh, Z. A., Miletich, R. S., Czarnecki, D., Dmochowski, J., Henschel, K., Janardhan, V, Dubey, N., & Kinkel, P. R. (2000) · Multiple Sclerosis Journal · doi:10.1177/135245850000600308 · Cited by 480
Self-citationMRI T2 shortening (‘black T2’) in multiple sclerosis: frequency, location, and clinical correlation
Bakshi, R., Shaikh, Z. A., & Janardhan, V. (2000) · NeuroReport · doi:10.1097/00001756-200001170-00004 · Cited by 92
Self-citation
Cited by
Schmidt, R., Ropele, S., Enzinger, C., Petrovic, K., Smith, S., Schmidt, H., Matthews, P. M., & Fazekas, F. (2005) · Annals of Neurology · doi:10.1002/ana.20630 · Cited by 408
Characterizing iron deposition in multiple sclerosis lesions using susceptibility weighted imaging
Haacke, E. M., Makki, M., Ge, Y., Maheshwari, M., Sehgal, V., Hu, J., Selvan, M., Wu, Z., Latif, Z., Xuan, Y., et al. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21676 · Cited by 329
Cerebrospinal fluid tracer efflux to parasagittal dura in humans
Ringstad, G., & Eide, P. K. (2020) · Nature Communications · doi:10.1038/s41467-019-14195-x · Cited by 292
Dulamea, A. O. (2017) · Advances in Experimental Medicine and Biology · doi:10.1007/978-3-319-47861-6_7 · Cited by 128
Bakshi, R., Dmochowski, J., Shaikh, Z. A., & Jacobs, L. (2001) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(01)00477-4 · Cited by 107
Self-citation
Metadata
- Authors
- Bakshi, R., Ariyaratana, S., Benedict, R. H. B., & Jacobs, L.
- Venue
- Archives of Neurology
- Publisher
- American Medical Association (AMA)
- Published
- 2001-05-01
- Volume
- 58
- Issue
- 5
- Pages
- 742
- ISSN
- 0003-9942 (ISSN-L)
- OpenAlex
- W2077031657
- Cited by
- 216
- References
- 4
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Detects Cortical and Juxtacortical Multiple Sclerosis Lesions. https://app.cochat.ai/papers/10.1001/archneur.58.5.742
- The paper
- Bakshi, R., Ariyaratana, S., Benedict, R. H. B., & Jacobs, L. (2001). Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Detects Cortical and Juxtacortical Multiple Sclerosis Lesions. Archives of Neurology. https://doi.org/10.1001/archneur.58.5.742
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.