Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 210

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Imaging Cortical Lesions in Multiple Sclerosis With Ultra–High-Field Magnetic Resonance Imaging

Open access
Pitt, David, Boster, Aaron, Pei, Wei, Wohleb, Eric, Jasne, Adam, Zachariah, Cherian R., Rammohan, Kottil, Knopp, Michael V., Schmalbrock, Petra · 2010 · Archives of Neurology

Abstract

OBJECTIVE: To determine the sensitivity of T2*-weighted gradient-echo (T2*GRE) and inversion recovery turbo-field-echo (TFE) sequences for cortical multiple sclerosis lesions at 7 T. DESIGN, SETTING, AND PARTICIPANTS: Autopsied brain tissue from individuals with multiple sclerosis was scanned with 3-dimensional T2*GRE and 3-dimensional inversion recovery white matter-attenuated TFE sequences at 7 T. Cortical lesions visible with either sequence were scored for each anatomical lesion type. Imaged brain tissue was then processed for immunohistochemical analysis, and cortical lesions were identified by labeling with antibody against myelin basic protein and CD68 for microglia. Magnetic resonance images were matched with corresponding histological sections and scored retrospectively to determine the sensitivity for each cortical lesion type. Main Outcome Measure Cortical lesion detection by 3-dimensional T2*GRE and white matter-attenuated TFE sequences. RESULTS: The 3-dimensional T2*GRE and white matter-attenuated TFE sequences retrospectively detected 93% and 82% of all cortical lesions, respectively (with varying sensitivities for different lesion types). Lesion visibility was primarily determined by size as all undetected lesions were smaller than 1.1 mm at their smallest diameter. The T2*GRE images showed hypointense rings in some cortical lesions that corresponded with increased density of activated microglia. CONCLUSIONS: Three-dimensional T2*GRE and white matter-attenuated TFE sequences at a 7-T field strength detect most cortical lesions in postmortem multiple sclerosis tissue. This study indicates the potential of T2*GRE and white matter-attenuated TFE sequences in ultra-high-field magnetic resonance imaging for cortical lesion detection in patients with multiple sclerosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archneurol.2010.148

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 210

Metadata

Authors
Pitt, D., Boster, A., Pei, W., Wohleb, E., Jasne, A., Zachariah, C. R., Rammohan, K., Knopp, M. V., & Schmalbrock, P.
Venue
Archives of Neurology
Published
2010-07-01
Volume
67
Issue
7
Pages
812-8
ISSN
0003-9942 (ISSN-L)
OpenAlex
W2055547320
Cited by
210
References
2
FWCI
9.42
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Imaging Cortical Lesions in Multiple Sclerosis With Ultra–High-Field Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1001/archneurol.2010.148
The paper
Pitt, D., Boster, A., Pei, W., Wohleb, E., Jasne, A., Zachariah, C. R., Rammohan, K., Knopp, M. V., & Schmalbrock, P. (2010). Imaging Cortical Lesions in Multiple Sclerosis With Ultra–High-Field Magnetic Resonance Imaging. Archives of Neurology. https://doi.org/10.1001/archneurol.2010.148

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.