Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 848

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Psychometric Properties of the National Eye Institute Visual Function Questionnaire (NEI-VFQ)

Open access
Mangione, Carol M.·1998·Archives of Ophthalmology

Abstract

OBJECTIVE: To test the reliability and validity of the 51-item Field Test Version of the National Eye Institute Visual Function Questionnaire (NEI-VFQ) across 5 common chronic eye conditions. DESIGN: Prospective observational cohort study of persons with 1 of 5 chronic eye diseases who were scheduled for nonurgent visits in ophthalmology practices or had low vision from any cause, and a reference sample of persons without eye disease. SETTING: Six university-based ophthalmology practices and the National Eye Institute Clinical Center, Bethesda, Md. PATIENTS: Eligible participants had to have 1 of the following eye conditions: age-related cataracts, age-related macular degeneration, diabetic retinopathy, primary open-angle glaucoma, cytomegalovirus retinitis, or low vision from any cause. Each of the 7 sites also enrolled persons in a reference sample. Reference sample participants had no evidence of underlying eye disease but were scheduled for either screening eye examinations or correction of refractive error. All eligible persons had to be aged 21 years or older, English speaking, and cognitively able to give informed consent and participate in a health status interview. MEASUREMENTS AND MAIN RESULTS: To provide the data needed to assess the reliability and validity of the 51-item NEI-VFQ, all subjects completed an interview that consisted of the 51-item NEI-VFQ, the Medical Outcomes Study 36-Item Short-Form Health Survey, and at least 1 measure of vision-targeted functional status. Estimates of internal consistency and test-retest reproducibility indicate that the 51-item NEI-VFQ is reliable. Tests of association with other scales and clinical variables support the construct validity of the survey. CONCLUSIONS: In this cross-sectional study, the 51-item NEI-VFQ seems to be reliable and valid and should be a useful tool for group-level comparisons of vision-targeted, health-related quality of life in clinical research. Additionally, the psychometric properties of the NEI-VFQ were not influenced by the type or severity of the underlying eye disease, suggesting that the measure will provide reproducible and valid data when used across multiple eye conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archopht.116.11.1496

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 848

Metadata

Authors
Mangione, C. M.
Venue
Archives of Ophthalmology
Published
1998-11-01
Volume
116
Issue
11
Pages
1496
ISSN
0003-9950 (ISSN-L)
OpenAlex
W2161217162
Cited by
848
References
2
FWCI
11.09
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Psychometric Properties of the National Eye Institute Visual Function Questionnaire (NEI-VFQ). https://app.cochat.ai/papers/10.1001/archopht.116.11.1496
The paper
Mangione, C. M. (1998). Psychometric Properties of the National Eye Institute Visual Function Questionnaire (NEI-VFQ). Archives of Ophthalmology. https://doi.org/10.1001/archopht.116.11.1496

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.