The DOI matches its Crossref record.
Diode Laser Transscleral Cyclophotocoagulation as a Primary Surgical Treatment for Primary Open-angle Glaucoma
Abstract
OBJECTIVES: To evaluate the feasibility of diode laser transscleral cyclophotocoagulation (TSCPC) as a primary surgical treatment for primary open-angle glaucoma and to compare 2 laser energy settings used for treatment. METHODS: In a prospective clinical trial in Cape Coast and Accra, Ghana, 1 eye of each of 92 patients with primary open-angle glaucoma was treated by diode laser TSCPC as a primary surgical treatment. Eyes were randomly assigned to receive treatment by 20 applications of either 1.5 W applied for 1.5 seconds or 1.25 W applied for 2.5 seconds. RESULTS: Seventy-nine (86%) of 92 patients completed 3 months of follow-up; follow-up was 13.2 +/- 6.0 months (mean +/- SD). Intraocular pressure decreased in 53 (67%) of the 79 eyes. The drop in intraocular pressure was 20% or more in 37 eyes (47%) and final intraocular pressure was 22 mm Hg or less in 38 eyes (48%). An atonic pupil was a previously unreported complication that arose in 27 (28%) of 92 eyes. There were no serious complications of hypotony, phthisis bulbi, or sympathetic ophthalmia. Visual acuity decreased in 18 (23%) of 79 eyes treated by TSCPC and in 10 (23%) of 47 fellow eyes treated only with glaucoma medications. There was no difference in outcomes between the 2 laser energy settings. CONCLUSIONS: Diode laser TSCPC is a practical, rapid, well-tolerated procedure that may provide a modest and variable lowering of intraocular pressure. The treatment, used with conservative energy levels applied to the eye, seems to have few serious complications, although a previously unrecognized complication of atonic pupil needs further evaluation. A moderate variation in laser energy settings does not influence the results of treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Current management of glaucoma
Lusthaus, J., & Goldberg, I. (2019) · Medical Journal of Australia · doi:10.5694/mja2.50020 · Cited by 354
Glaucoma treatment trends: a review
Conlon, R., Saheb, H., & Ahmed, I. I. K. (2017) · Canadian Journal of Ophthalmology · doi:10.1016/j.jcjo.2016.07.013 · Cited by 344
Aquino, M. C. D., Barton, K., Tan, A. M. W., Sng, C., Li, X., Loon, S. C., & Chew, P. T. (2015) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.12360 · Cited by 343
Metadata
- Authors
- Egbert, P. R.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2001-03-01
- Volume
- 119
- Issue
- 3
- Pages
- 345
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2147213528
- Cited by
- 183
- References
- 0
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diode Laser Transscleral Cyclophotocoagulation as a Primary Surgical Treatment for Primary Open-angle Glaucoma. https://app.cochat.ai/papers/10.1001/archopht.119.3.345
- The paper
- Egbert, P. R. (2001). Diode Laser Transscleral Cyclophotocoagulation as a Primary Surgical Treatment for Primary Open-angle Glaucoma. Archives of Ophthalmology. https://doi.org/10.1001/archopht.119.3.345
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.