The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Evidence-Based Estimates of Outcome in Patients Irradiated for Intraocular Melanoma
Abstract
BACKGROUND: Melanoma of the eye is the only potentially fatal ocular malignancy in adults. Until radiation therapy gained wide acceptance in the 1980s, enucleation was the standard treatment for the tumor. Long-term results after proton beam irradiation are now available. METHODS: We developed risk score equations to estimate probabilities of the 4 principal treatment outcomes-local tumor recurrence, death from metastasis, retention of the treated eye, and vision loss-based on an analysis of 2069 patients treated with proton beam radiation for intraocular melanoma between July 10, 1975, and December 31, 1997. Median follow-up in surviving patients was 9.4 years. RESULTS: Tumor regrowth occurred in 60 patients, and 95% of tumors (95% confidence interval, 93%-96%) were controlled locally at 15 years. Risk scores were developed for the other 3 outcomes studied. Overall, the treated eye was retained by 84% of patients (95% confidence interval, 80%-87%) at 15 years. The probabilities for vision loss (visual acuity worse than 20/200) ranged from 100% to 20% at 10 years and for death from tumor metastases from 95% to 35% at 15 years, depending on the risk group. CONCLUSIONS: High-dose radiation treatment was highly effective in achieving local control of intraocular melanomas. In most cases, the eye was salvaged, and functional vision was retained in many patients. The mortality rate was high in an identifiable subset of patients who may benefit from adjuvant therapies directed at microscopic liver metastases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Proportional hazards tests and diagnostics based on weighted residuals
GRAMBSCH, P. M., & THERNEAU, T. M. (1994) · Biometrika · doi:10.1093/biomet/81.3.515 · Cited by 5,885
The Robust Inference for the Cox Proportional Hazards Model
Lin, D. Y., & Wei, L. J. (1989) · Journal of the American Statistical Association · doi:10.1080/01621459.1989.10478874 · Cited by 2,695
Test of the National Death Index and Equifax Nationwide Death Search
Rich-Edwards, J. W., Corsano, K. A., & Stampfer, M. J. (1994) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a117191 · Cited by 530
Cited by
Treatment of uveal melanoma: where are we now?
Yang, J., Manson, D. K., Marr, B. P., & Carvajal, R. D. (2018) · Therapeutic Advances in Medical Oncology · doi:10.1177/1758834018757175 · Cited by 300
Proton vs carbon ion beams in the definitive radiation treatment of cancer patients
Suit, H., DeLaney, T., Goldberg, S., Paganetti, H., Clasie, B., Gerweck, L., Niemierko, A., Hall, E., Flanz, J., Hallman, J., et al. (2010) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2010.01.015 · Cited by 290
Metadata
- Authors
- Gragoudas, E.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2002-12-01
- Volume
- 120
- Issue
- 12
- Pages
- 1665
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2071696483
- Cited by
- 192
- References
- 3
- FWCI
- 7.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evidence-Based Estimates of Outcome in Patients Irradiated for Intraocular Melanoma. https://app.cochat.ai/papers/10.1001/archopht.120.12.1665
- The paper
- Gragoudas, E. (2002). Evidence-Based Estimates of Outcome in Patients Irradiated for Intraocular Melanoma. Archives of Ophthalmology. https://doi.org/10.1001/archopht.120.12.1665
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.