The Relation of Retinal Vessel Caliber to the Incidence and Progressionof Diabetic Retinopathy: XIX: The Wisconsin Epidemiologic Study of Diabetic Retinopathy

Klein, Ronald · 2004 · Archives of Ophthalmology

Abstract

OBJECTIVE: To describe the relation of retinal arteriolar and venular caliber to the incidence and progression of diabetic retinopathy in people with type 1 diabetes mellitus. DESIGN: Incidence findings in a population-based study of diabetic retinopathy in Wisconsin. Participants included 996 persons diagnosed as having diabetes mellitus before 30 years of age who took insulin and underwent the baseline examination, 891 in the 4-year follow-up, 765 in the 10-year follow-up, and 634 in the 14-year follow-up. Retinal photographs of 7 standard fields were taken at all examinations. Computer-assisted grading was performed from a digitized image of field 1 to determine the average diameter of retinal arterioles and venules and their ratio. Main outcome measures included incidence and progression of retinopathy, incidence of proliferative retinopathy, and macular edema. RESULTS: While adjusting for other factors, larger arteriolar (relative risk [RR] for the fourth vs first quartile range, 2.04; 95% confidence interval [CI], 1.20-3.47; test of trend, P =.008) and venular diameters (RR, 2.33; 95% CI, 1.37-3.95; test of trend, P =.005) were associated with greater 4-year progression of retinopathy. Larger venular diameters (RR, 4.28; 95% CI, 1.50-12.19; test of trend, P =.006) but not arteriolar diameters were associated with greater 4-year incidence of proliferative retinopathy. In multivariable analyses, arteriolar and venular calibers were not associated with the 4-year incidence of retinopathy. While adjusting for other factors, arteriolar and venular calibers were not associated with incidence of macular edema at 4 years. There were few associations of arteriolar or venular caliber with the 10- or 14-year incidence or the progression of retinopathy. CONCLUSIONS: Larger arteriolar and venular caliber, independent of retinopathy severity level, is related to the progression of retinopathy, and larger venular caliber is associated with the 4-year incidence of proliferative retinopathy. Caliber of retinal vessels is not associated with incident retinopathy. These data suggest a quantitative measure of retinal vascular caliber provides additional information regarding risk for progression of retinopathy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archopht.122.1.76

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 235

Metadata

Authors
Klein, R.
Venue
Archives of Ophthalmology
Published
2004-01-01
Volume
122
Issue
1
Pages
76
ISSN
0003-9950 (ISSN-L)
OpenAlex
W2097513933
Cited by
235
References
1
FWCI
15.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Relation of Retinal Vessel Caliber to the Incidence and Progressionof Diabetic Retinopathy: XIX: The Wisconsin Epidemiologic Study of Diabetic Retinopathy. https://app.cochat.ai/papers/10.1001/archopht.122.1.76
The paper
Klein, R. (2004). The Relation of Retinal Vessel Caliber to the Incidence and Progressionof Diabetic Retinopathy: XIX: The Wisconsin Epidemiologic Study of Diabetic Retinopathy. Archives of Ophthalmology. https://doi.org/10.1001/archopht.122.1.76

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.