Detection of Diabetic Foveal Edema: Contact Lens Biomicroscopy Compared With Optical Coherence Tomography
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To compare contact lens biomicroscopy with optical coherence tomography (OCT) for the detection of diabetic foveal edema. METHODS: Study participants consisted of a convenient cohort of consecutive patients with diabetes mellitus seen at the Wilmer Eye Institute's Retinal Vascular Center, Baltimore, MD. Case characteristics were recorded and eyes were examined by 1 of 4 retina specialists by means of contact lens biomicroscopy. Edema involving the center of the macula was assessed as definitely present, questionably present, or definitely not present. The OCT testing was performed and interpreted by trained technicians, masked to the physicians' assessment of foveal edema. Agreement between OCT and contact lens examination for the absence or presence of foveal edema was evaluated. RESULTS: One hundred seventy-two eyes of 95 patients with diabetes were enrolled in August and September 2002. Foveal thickness was objectively measured by OCT in 170 (99%) of 172 cases. We found excellent agreement between OCT and contact lens examination for the absence or presence of foveal edema when OCT thickness was normal ( 300 microm). However, agreement was poor when foveal thickness was mildly increased on OCT (201-300 microm). CONCLUSIONS: Agreement between contact lens examination and OCT for the detection of diabetic foveal edema is poor when OCT thickening is mild. This suggests that contact lens biomicroscopy is relatively insensitive for the detection of mild foveal thickening apparent on OCT. Additional studies are needed to investigate the natural course of cases with mildly increased foveal thickness on OCT that do not appear thickened clinically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634 · cited 1×
“In an era when ancillary testing is available to supplement clinical examination of diabetic patients, we recommend the following: (1) The presence of macular edema can be detected with noncontact lens examinations.”
BackgroundIntravitreal triamcinolone for refractory diabetic macular edema
Martidis, A., Duker, J. S., Greenberg, P. B., Rogers, A. H., Puliafito, C. A., Reichel, E., & Baumal, C. (2002) · Ophthalmology · doi:10.1016/s0161-6420(02)00975-2 · Cited by 1,032
Topography of diabetic macular edema with optical coherence tomography
Hee, M. R., Puliafito, C. A., Duker, J. S., Reichel, E., Coker, J. G., Wilkins, J. R., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)93601-6 · Cited by 633 · cited 1×
“Race White 114 (66) African American 48 (28) Asian 5 (3) Other 5 (3) Gender Men 88 (51) Women 84 (49) Diabetes type Early onset 35 (20) Late onset 137 (80) Lens status Phakic 134 (78) Pseudophakic 38 (22) Level of diabetic retinopathy None 4 (2) Mild nonproliferative 23 (13) Moderate nonproliferative 43 (25) Severe no…”
BackgroundRetinal thickness study with optical coherence tomography in patients with diabetes.
Sánchez-Tocino, H., Alvárez-Vidal, A., Maldonado, M. J., Moreno‐Montañés, J., & García‐Layana, A. (2002) · PubMed · Cited by 251
Diabetic macular edema assessed with optical coherence tomography and stereo fundus photography.
Strøm, C., Sander, B., Larsen, N. B., Larsen, M., & Lund‐Andersen, H. (2002) · PubMed · Cited by 117
Polito, A., Shah, S. M., Haller, J. A., et al. (2002) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(02)01528-3 · Cited by 91 · cited 1×
“Race White 114 (66) African American 48 (28) Asian 5 (3) Other 5 (3) Gender Men 88 (51) Women 84 (49) Diabetes type Early onset 35 (20) Late onset 137 (80) Lens status Phakic 134 (78) Pseudophakic 38 (22) Level of diabetic retinopathy None 4 (2) Mild nonproliferative 23 (13) Moderate nonproliferative 43 (25) Severe no…”
BackgroundFritsche, P. L., van der Heijde, R. G. L., Suttorp-Schulten, M. S. A., & Polak, B. C. P. (2002) · Retina · doi:10.1097/00006982-200212000-00013 · Cited by 34
Cited by
Diabetic Macular Edema: Pathogenesis and Treatment
Bhagat, N., Grigorian, R. A., Tutela, A., & Zarbin, M. A. (2009) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.10.001 · Cited by 571
Kaur, C., Foulds, W. S., & Ling, E. A. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2008.09.003 · Cited by 470
Normal Macular Thickness Measurements in Healthy Eyes Using Stratus Optical Coherence Tomography
Chan, A. (2006) · Archives of Ophthalmology · doi:10.1001/archopht.124.2.193 · Cited by 424
Optical Coherence Tomographic Patterns of Diabetic Macular Edema
Kim, B. Y., Smith, S. D., & Kaiser, P. K. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.04.023 · Cited by 290
Kim, S. J., Equi, R., & Bressler, N. M. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.08.053 · Cited by 268
Virgili, G., Menchini, F., Casazza, G., Hogg, R., Das, R. R., Wang, X., & Michelessi, M. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008081.pub3 · Cited by 265
Optical coherence tomography of the retina and optic nerve – a review
Sakata, L. M., DeLeon‐Ortega, J., Sakata, V., & Girkin, C. A. (2009) · Clinical & Experimental Ophthalmology · doi:10.1111/j.1442-9071.2009.02015.x · Cited by 264
Robust and data-efficient generalization of self-supervised machine learning for diagnostic imaging
Azizi, S., Culp, L., Freyberg, J., Mustafa, B., Baur, S., Kornblith, S., Chen, T., Tomasev, N., Mitrović, J., Strachan, P., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01049-7 · Cited by 250
Diabetic macular edema: Evidence-based management
Stewart, M., Browning, D., & Lee, C. (2018) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_1240_18 · Cited by 237
“[4] The term subclinical DME has been used to define both of these classes of DME that are less severe than clinically significant DME.[92,93] Figure 1: A macular lipid star is a common fundus sign in diabetic macular edema and indicates that the center of the macula is a preferential site for accumulation of extracel…”
BackgroundMethodAnti-vascular endothelial growth factor for diabetic macular oedema: a network meta-analysis
Virgili, G., Parravano, M., Evans, J. R., Gordon, I., & Lucenteforte, E. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007419.pub5 · Cited by 228
Brown, D. M., & Regillo, C. D. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2007.06.039 · Cited by 224
Fingolimod-associated macular edema: Incidence, detection, and management
Jain, N., & Bhatti, M. T. (2012) · Neurology · doi:10.1212/wnl.0b013e318248deea · Cited by 202
Anti-vascular endothelial growth factor for diabetic macular oedema
Virgili, G., Parravano, M., Menchini, F., & Evans, J. R. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007419.pub4 · Cited by 184
Anti-vascular endothelial growth factor for diabetic macular oedema: a network meta-analysis
Virgili, G., Parravano, M., Evans, J. R., Gordon, I., & Lucenteforte, E. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007419.pub6 · Cited by 184
“Since its introduction, OCT was found to be in good agreement with the clinical gold standard (slit-lamp examination with a contact lens) for detecting the presence of macular oedema and was found to be potentially more sensitive in cases of mild foveal thickening (Brown 2004).”
ResultBrowning, D. J., Glassman, A. R., Aiello, L. P., Bressler, N. M., Bressler, S. B., Danis, R. P., Davis, M. D., Ferris, F. L., Huang, S. S., Kaiser, P. K., et al. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.12.004 · Cited by 164
Optical Coherence Tomography Use in Evaluation of the Vitreoretinal Interface: A Review
Mirza, R. G., Johnson, M. W., & Jampol, L. M. (2007) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2007.04.007 · Cited by 158
Metadata
- Authors
- Brown, J. C.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2004-03-01
- Volume
- 122
- Issue
- 3
- Pages
- 330
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2158769384
- Cited by
- 212
- References
- 7
- FWCI
- 15.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.