Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 424

The DOI matches its Crossref record.

Normal Macular Thickness Measurements in Healthy Eyes Using Stratus Optical Coherence Tomography

Open access
Chan, Annie·2006·Archives of Ophthalmology

Abstract

OBJECTIVE: To report normal macular thickness measurements in healthy eyes using the latest commercially available optical coherence tomography (OCT) mapping software, version 3.0, from the Stratus OCT (OCT3). METHODS: Thirty-seven eyes from 37 healthy subjects underwent a complete ophthalmologic examination, including OCT. Six radial scans, 6 mm in length and centered on the fovea, were obtained using the OCT3. Retinal thickness was automatically calculated by OCT mapping software. Measurements were displayed as the mean and standard deviation for each of the 9 regions defined in the Early Treatment Diabetic Retinopathy Study. RESULTS: Foveal thickness (mean thickness in the central 1000-microm diameter area) and central foveal thickness (mean thickness at the point of intersection of 6 radial scans) on the OCT3 were 212 +/- 20 and 182 +/- 23 microm, respectively. Macular thickness measurements were thinnest at the center of the fovea, thickest within 3-mm diameter of the center, and diminished toward the periphery of the macula. The temporal quadrant was thinner than the nasal quadrant. Central foveal thickness was also manually determined as 170 +/- 18 microm, approximately 12 microm less than the value automatically obtained from the OCT3 software. There was no correlation between age and foveal thickness (P = .80). CONCLUSIONS: Mean foveal thickness measurements were 38 to 62 microm thicker than previously reported values, while mean central foveal thickness measurements were 20 to 49 microm thicker than previously published values. This discrepancy should be considered when interpreting OCT scans.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archopht.124.2.193

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 424

Metadata

Authors
Chan, A.
Venue
Archives of Ophthalmology
Published
2006-02-01
Volume
124
Issue
2
Pages
193
ISSN
0003-9950 (ISSN-L)
OpenAlex
W2168451815
Cited by
424
References
0
FWCI
24.35
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Normal Macular Thickness Measurements in Healthy Eyes Using Stratus Optical Coherence Tomography. https://app.cochat.ai/papers/10.1001/archopht.124.2.193
The paper
Chan, A. (2006). Normal Macular Thickness Measurements in Healthy Eyes Using Stratus Optical Coherence Tomography. Archives of Ophthalmology. https://doi.org/10.1001/archopht.124.2.193

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.