Optic Nerve Sheath Decompression for Nonarteritic Ischemic Optic Neuropathy Improves Multiple Visual Function Measurements
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Optic nerve sheath decompression was performed in seven patients with nonarteritic anterior ischemic optic neuropathy. Visual function was evaluated by measurement of visual acuity with standardized Early Treatment Diabetic Retinopathy Study charts, color vision testing, quantitation of relative afferent pupillary defects with neutral-density filters, and Goldmann and Humphrey perimetry. Visual acuity improved markedly in all patients (at least doubling of the visual angle); the peripheral visual field expanded by at least 20 degrees (as measured by Goldmann perimetry) in six patients. Three patients also experienced marked improvement in color vision, relative afferent pupillary defect, and foveal sensitivity. Our experience supports the possible beneficial effect of optic nerve sheath decompression in patients with nonarteritic anterior ischemic optic neuropathy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical profile and long-term implications of anterior ischemic optic neuropathy
Repka, M. X., Savino, P. J., Schatz, N. J., & Sergott, R. C. (1983) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)77911-5 · Cited by 255
Cited by
Hayreh, S. S. (2009) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2008.11.002 · Cited by 656
“(1989) and a few other anecdotal reports (Kelman and Elman, 1991; Spoor et al., 1991), the procedure gained world-wide favor not only in ‘‘progressive’’ but also in all types of NA-AION.”
ResultDickersin, K. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03520320035038 · Cited by 393
Miller, N. R., & Arnold, A. C. (2015) · Eye · doi:10.1038/eye.2014.144 · Cited by 245
Optic Neuritis and Ischemic Optic Neuropathy: Overlapping Clinical Profiles
Rizzo, J. F. (1991) · Archives of Ophthalmology · doi:10.1001/archopht.1991.01080120052024 · Cited by 204
Metadata
- Authors
- Kelman, S. E.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 1991-05-01
- Volume
- 109
- Issue
- 5
- Pages
- 667
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W1979557045
- Cited by
- 57
- References
- 1
- FWCI
- 9.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optic Nerve Sheath Decompression for Nonarteritic Ischemic Optic Neuropathy Improves Multiple Visual Function Measurements. https://app.cochat.ai/papers/10.1001/archopht.1991.01080050081034
- The paper
- Kelman, S. E. (1991). Optic Nerve Sheath Decompression for Nonarteritic Ischemic Optic Neuropathy Improves Multiple Visual Function Measurements. Archives of Ophthalmology. https://doi.org/10.1001/archopht.1991.01080050081034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.