Sustained-Release Ganciclovir Therapy for Treatment of Cytomegalovirus Retinitis: Use of an Intravitreal Device
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
A surgically implantable device for sustained intravitreal release of ganciclovir has been developed. The device delivers ganciclovir intraocularly over approximately 4 to 5 months. Eight patients with acquired immunodeficiency syndrome (AIDS) and associated cytomegalovirus (CMV) retinitis were recruited as part of a phase 1 study. Thirteen eyes with active CMV retinitis underwent surgical implantation of the ganciclovir device. All eyes showed resolution of the CMV retinitis; none showed progression. Visual acuity remained unchanged in three eyes, improved in six eyes, and decreased in four eyes. Surgical complications included mild vitreous hemorrhage, astigmatism, and suprachoroidal placement of the device. Retinal detachment occurred in three eyes as the retinitis resolved. This new intraocular drug delivery system offers many advantages compared with intravenous therapy or repeated intravitreal ganciclovir injections for the management of CMV retinitis in patients with AIDS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acquired Immune Deficiency Syndrome
Holland, G. N., Pepose, J. S., Pettit, T. H., Gottlieb, M. S., Yee, R. D., & Foos, R. Y. (1983) · Ophthalmology · doi:10.1016/s0161-6420(83)80009-8 · Cited by 840
Faulds, D., & Heel, R. C. (1990) · Drugs · doi:10.2165/00003495-199039040-00008 · Cited by 400
Cytomegalovirus Retinitis and Acquired Immunodeficiency Syndrome
Jabs, D. A. (1989) · Archives of Ophthalmology · doi:10.1001/archopht.1989.01070010077031 · Cited by 379
Biron, K. K., Stanat, S. C., Sorrell, J. B., Fyfe, J. A., Keller, P. M., Lambe, C. U., & Nelson, D. J. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.8.2473 · Cited by 236
Henry, K., Cantrill, H., Fletcher, C., Chinnock, B. J., & Balfour, H. H. (1987) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)74163-7 · Cited by 196
Treatment of Cytomegalovirus Retinitis with Intravitreal Ganciclovir
Cantrill, H. L., Henry, K., Melroe, N. H., Knobloch, W. H., Ramsay, R. C., & Balfour, H. H. (1989) · Ophthalmology · doi:10.1016/s0161-6420(89)32900-9 · Cited by 185
Longitudinal Study of Cytomegalovirus Retinitis in Acquired Immune Deficiency Syndrome
Gross, J. G., Bozzette, S. A., Mathews, W. C., Spector, S. A., Abramson, I. S., McCutchan, J. A., Mendez, T., Munguia, D., & Freeman, W. R. (1990) · Ophthalmology · doi:10.1016/s0161-6420(90)32552-6 · Cited by 162
Intravitreal Sustained-Release Ganciclovir
Smith, T. J. (1992) · Archives of Ophthalmology · doi:10.1001/archopht.1992.01080140111037 · Cited by 157
Intravitreal Ganciclovir in the Treatment of AIDS-associated Cytomegalovirus Retinitis
Ussery, F. M., Gibson, S. R., Conklin, R. H., Piot, D. F., Stool, E. W., & Conklin, A. J. (1988) · Ophthalmology · doi:10.1016/s0161-6420(88)33147-7 · Cited by 148
Long-term Intravitreal Ganciclovir Therapy for Cytomegalovirus Retinopathy
Heinemann, M. H. (1989) · Archives of Ophthalmology · doi:10.1001/archopht.1989.01070020849025 · Cited by 147
Randomized prospective trial of ganciclovir maintenance therapy for cytomegalovirus retinitis
Jacobson, M. Z., O’Donnell, J. J., Brodie, H. R., et al. (1988) · Journal of Medical Virology · doi:10.1002/jmv.1890250311 · Cited by 81
Intravitreal Toxicity of Hydroxyacyclovir (BW-B759U), a New Antiviral Agent
Pulido, J. S., Peyman, G. A., Lesar, T. S., & Vernot, J. (1985) · Archives of Ophthalmology · doi:10.1001/archopht.1985.01050060100036 · Cited by 41
Cited by
An overview of clinical and commercial impact of drug delivery systems
Anselmo, A. C., & Mitragotri, S. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.03.053 · Cited by 520
Nanotechnology in ocular drug delivery
Sahoo, S. K., Dilnawaz, F., & Krishnakumar, S. (2008) · Drug Discovery Today · doi:10.1016/j.drudis.2007.10.021 · Cited by 510
Campochiaro, P. A., Brown, D. M., Pearson, A., Ciulla, T., Boyer, D., Holz, F. G., Tolentino, M., Gupta, A., Duarte, L., Madreperla, S., et al. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2010.12.028 · Cited by 405
Nanotechnology in Ocular Drug Delivery
Patel, D., Pathak, D., & Giradkar, P. (2021) · Nanocarriers: Drug Delivery System · doi:10.1007/978-981-33-4497-6_18 · Cited by 362
Martin, D. F. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090240037023 · Cited by 338
Metadata
- Authors
- Sanborn, G. E.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 1992-02-01
- Volume
- 110
- Issue
- 2
- Pages
- 188
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W1993433202
- Cited by
- 230
- References
- 12
- FWCI
- 24.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.