Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 334

The DOI matches its Crossref record.

The Collaborative Corneal Transplantation Studies (CCTS): Effectiveness of Histocompatibility Matching in High-Risk Corneal Transplantation

·1992·Archives of Ophthalmology

Abstract

• The Collaborative Corneal Transplantation Studies (CCTS) were designed to evaluate the effect of donor-recipient histocompatibility matching and crossmatching on the survival of corneal transplants in high-risk patients. Corneas were allocated to the 419 patients in the double-masked Antigen Matching Study on the basis of serologically defined HLA-A, -B and HLA-DR antigen match. ABO blood group compatibility was determined but not used for recipient selection. The 37 patients in the Crossmatch Study were randomly assigned to receive a cornea from either a positively or negatively crossmatched donor. All patients received topical steroid therapy according to a standard protocol. Matching for HLA-A, -B and HLA-DR antigens had no effect on overall graft survival, the incidence of irreversible rejection, or the incidence of rejection episodes. At 3 years after surgery, the estimated proportion of eyes with graft failure was 41% for the ABO-incompatible group and 31% for the ABOcompatible group (relative risk, 1.43; 95% confidence interval, 1.00 to 2.06). The estimated proportion of eyes with failure from rejection by 3 years was 30% for the ABO-incompatible group and 16% for the ABO-compatible group (relative risk, 1.98; 95% confidence interval, 1.25 to 3.13). The positive group in the Crossmatch Study had fewer graft failures, rejection failures, and rejection episodes than the negative group; however, these differences were not statistically significant. These studies demonstrate that, for high-risk patients who are immunosuppressed by topical steroid therapy and followed up according to the CCTS protocol: (1) neither HLA-A, -B nor HLA-DR antigen matching substantially reduces the likelihood of corneal graft failure; (2) a positive donor-recipient crossmatch does not dramatically increase the risk of corneal graft failure; and (3) ABO blood group matching, which can be achieved with relatively little effort and expense, may be effective in reducing the risk of graft failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archopht.1992.01080220054021

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 334

Metadata

Venue
Archives of Ophthalmology
Published
1992-10-01
Volume
110
Issue
10
Pages
1392
ISSN
0003-9950 (ISSN-L)
OpenAlex
W4255053507
Cited by
334
References
0
FWCI
8.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Collaborative Corneal Transplantation Studies (CCTS): Effectiveness of Histocompatibility Matching in High-Risk Corneal Transplantation. https://app.cochat.ai/papers/10.1001/archopht.1992.01080220054021
The paper
The Collaborative Corneal Transplantation Studies (CCTS): Effectiveness of Histocompatibility Matching in High-Risk Corneal Transplantation. (1992). Archives of Ophthalmology. https://doi.org/10.1001/archopht.1992.01080220054021

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.