The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magnetic Resonance Imaging in Patients With Low-Tension Glaucoma
Abstract
OBJECTIVE: To study diagnoses and anatomic findings found on magnetic resonance imaging in patients with low-tension glaucoma. PATIENTS: We included in this study magnetic resonance images of 20 consecutive patients with low-tension glaucoma. We individually matched each patient with low-tension glaucoma to a control with normal ocular findings who had magnetic resonance imaging for reasons unrelated to the visual pathway. DESIGN: We studied axial and coronal images of the orbit and optic nerve with digitizing software (Image-Pro Plus, Media Cybernetics, Silver Spring, Md). Statistical evaluation was with a Wilcoxon Signed Rank Test for anatomic findings and a McNemar Test for diagnosis. RESULTS: We found no difference between groups in the optic nerve diameter or length, the carotid artery area, or the distance from the optic nerve to the carotid artery (P > .05). Left optic nerve area was greater in the control patients than patients with low-tension glaucoma (P = .026). The prevalence of intracranial abnormalities, including meningioma, aneurysm, and arteriovenous abnormality, was similar between groups (P > .05). However, diffuse cerebral small-vessel ischemic changes were found more in patients with low-tension glaucoma (n = 8) than control patients (n = 1) (P = .0196). CONCLUSIONS: This study proposes a hypothesis that cerebral small-vessel ischemia is more common in patients with low-tension glaucoma and potentially reflects indirectly a vascular cause of the optic nerve head damage at least in a subgroup of patients. Importantly, further research still is required to provide direct evidence for a vascular cause involved in low-tension glaucoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boone, K. B. (1992) · Archives of Neurology · doi:10.1001/archneur.1992.00530290141024 · Cited by 400
Cited by
The impact of ocular blood flow in glaucoma
Flammer, J., Orgül, S., Costa, V. P., Orzalesi, N., Krieglstein, G. K., Serra, L. M., Renard, J.-P., & Stefánsson, E. (2002) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00008-3 · Cited by 1,709
(1998) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(98)00223-2 · Cited by 1,599
Risk factors for progression of visual field abnormalities in normal-tension glaucoma
Drance, S., Anderson, D. R., & Schulzer, M. (2001) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(01)00964-3 · Cited by 790
Glaucoma as a neurodegenerative disease
Gupta, N., & Yücel, Y. H. (2007) · Current Opinion in Ophthalmology · doi:10.1097/icu.0b013e3280895aea · Cited by 422
Optic nerve blood-flow abnormalities in glaucoma
Flammer, J. (1998) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(97)00006-2 · Cited by 365
Metadata
- Authors
- Stroman, G. A.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 1995-02-01
- Volume
- 113
- Issue
- 2
- Pages
- 168
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2167140057
- Cited by
- 177
- References
- 1
- FWCI
- 10.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Resonance Imaging in Patients With Low-Tension Glaucoma. https://app.cochat.ai/papers/10.1001/archopht.1995.01100020050027
- The paper
- Stroman, G. A. (1995). Magnetic Resonance Imaging in Patients With Low-Tension Glaucoma. Archives of Ophthalmology. https://doi.org/10.1001/archopht.1995.01100020050027
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.