24-Hour Blood Pressure Monitoring in Patients With Anterior Ischemic Optic Neuropathy

Landau, Klara · 1996 · Archives of Ophthalmology
Cited by 90

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To define parameters of ambulatory diurnal blood pressure in patients who had experienced anterior ischemic optic neuropathy (AION) in a case-controlled study. PARTICIPANTS AND METHODS: Twenty-four patients with AION and 24 control subjects who were matched for age, gender, medical diagnoses, and medications underwent ambulatory automated blood pressure monitoring for 24 hours. RESULTS: The overall diurnal pattern of blood pressure appeared to be normal in all subjects, showing lower blood pressures at night than during the day, an overnight nadir, and an ascending blood pressure curve in the morning to reach daytime levels. Also, patients with AION did not differ from control subjects with respect to the nighttime diastolic nadir or daytime peak systolic blood pressure. However, during the daytime, patients with AION had lower mean systolic and diastolic blood pressures than did matched control subjects. The widest difference between their blood pressure curves occurred after awakening in the morning, when patients with AION had a less steep and more irregular rise of blood pressure. Patients who had signs of vertebrobasilar insufficiency in addition to AION had lower mean diastolic blood pressure during both daytime and nighttime and a lower minimum daytime diastolic blood pressure. CONCLUSIONS: On ambulatory measurements of diurnal blood pressure, patients with AION consistently had a lower mean blood pressure than did control subjects and a lag in the usual rise in blood pressure in the morning to meet increasing daytime demands for perfusion. Chronic hypoperfusion of small end-arterial vessels that supply the optic nerve head may predispose to AION, and may be caused by relative hypotension owing to overtreated hypertension or to abnormal vascular autoregulation. Internists should be asked to monitor blood pressure carefully when treating hypertensive patients who are at risk for AION, to avoid hypotension, especially on awakening in the morning.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archopht.1996.01100130562012

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 90

Metadata

Authors
Landau, K.
Venue
Archives of Ophthalmology
Published
1996-05-01
Volume
114
Issue
5
Pages
570
ISSN
0003-9950 (ISSN-L)
OpenAlex
W1992616760
Cited by
90
References
3
FWCI
2.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 24-Hour Blood Pressure Monitoring in Patients With Anterior Ischemic Optic Neuropathy. https://app.cochat.ai/papers/10.1001/archopht.1996.01100130562012
The paper
Landau, K. (1996). 24-Hour Blood Pressure Monitoring in Patients With Anterior Ischemic Optic Neuropathy. Archives of Ophthalmology. https://doi.org/10.1001/archopht.1996.01100130562012

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.