The DOI matches its Crossref record.
A Massive Transfusion Protocol to Decrease Blood Component Use and Costs
Abstract
HYPOTHESIS: A massive transfusion protocol (MTP) decreases the use of blood components, as well as turnaround times, costs, and mortality. DESIGN: Retrospective before-and-after cohort study. SETTING: Academic level I urban trauma center. PATIENTS AND METHODS: Blood component use was compared in 132 patients during a 2-year period following the implementation of an MTP; 46 patients who were treated the previous year served as historical control subjects. INTERVENTION: Introduction of an MTP that included recombinant factor VIIa for patients with exsanguinating hemorrhage. MAIN OUTCOME MEASURES: The amount of each blood component transfused, turnaround times, blood bank and hospital charges, and mortality rates. RESULTS: After introduction of the MTP, there was a significant decrease in packed red blood cells, plasma, and platelet use. The turnaround time for the first shipment was less than 10 minutes, and the time between the first and second shipments was reduced from 42 to 18 minutes, compared with historical controls. The decreased use of blood products represented a savings of $2270 per patient or an annual savings of $200, 000, despite increased costs for recombinant factor VIIa. There was no difference in mortality in either group; it remained around 50%. Thromboembolic complications did not increase, despite a significant increase in the use of recombinant factor VIIa. CONCLUSIONS: The MTP resulted in a reduction in the use of blood components with improved turnaround times and significant savings. Mortality was unaffected. The use of recombinant factor VIIa did not increase thromboembolic complications in these patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Management of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Cannon, J. W., Khan, M. A., Raja, A. S., Cohen, M. J., Como, J. J., Cotton, B. A., Dubose, J. J., Fox, E. E., Inaba, K., Rodriguez, C. J., et al. (2017) · Journal of Trauma and Acute Care Surgery · doi:10.1097/ta.0000000000001333 · Cited by 481
FIBTEM provides early prediction of massive transfusion in trauma
Schöchl, H., Cotton, B., Inaba, K., Nienaber, U., Fischer, H., Voelckel, W., & Solomon, C. (2011) · Critical Care · doi:10.1186/cc10539 · Cited by 313
Cios, K. J., Krawczyk, B., Cios, J., & Staley, K. J. (2019) · arXiv · doi:10.48550/arxiv.1905.09203 · Cited by 9
Metadata
- Authors
- O’Keeffe, T.
- Venue
- Archives of Surgery
- Publisher
- American Medical Association (AMA)
- Published
- 2008-07-21
- Volume
- 143
- Issue
- 7
- Pages
- 686
- ISSN
- 0004-0010 (ISSN-L)
- OpenAlex
- W2102919367
- Cited by
- 179
- References
- 0
- FWCI
- 6.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Massive Transfusion Protocol to Decrease Blood Component Use and Costs. https://app.cochat.ai/papers/10.1001/archsurg.143.7.686
- The paper
- O’Keeffe, T. (2008). A Massive Transfusion Protocol to Decrease Blood Component Use and Costs. Archives of Surgery. https://doi.org/10.1001/archsurg.143.7.686
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.