The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Fibrin Sleeve Formation on Indwelling Subclavian Central Venous Catheters
Abstract
Fifty-five subclavian veins with previous indwelling catheters were dissected at autopsy. Two groups of subclavian catheters injected with contrast material during removal were studied by cinefluoroscopy. Group 1 consisted of 25 patients with indwelling Teflon and polyethylene catheters. Group 2 comprised six patients with indwelling graphite-benzakonium chloride-heparin sodium (GBH) bonded polyethylene catheters. The vein dissections and the cinefluoroscopic studies in group 1 revealed that totally circumferential fibrin sleeves consistently and extensively formed on indwelling subclavian catheters. They developed on polyethylene, Teflon, nylon, and siliconized rubber catheters. These fibrin sleeves were noted at dissection on catheters within 24 hours after insertion. Two associated thrombi were discovered. Cinefluoroscopy detected one additional thrombus. These findings are an undesirable potential hazard and concern of thromboembolism is certainly warranted. Methods to eliminate fibrin sleeves seem justified. Evidence suggests that GBH-bonded catheters significantly inhibit fibrin sleeve formation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long-Term Total Parenteral Nutrition with Growth, Development, and Positive Nitrogen Balance
Dudrick, S. J., Wilmore, D. W., Vars, H. M., & Rhoads, J. E. (2023) · 50 Landmark Papers every Pediatric Surgeon Should Know · doi:10.1201/b23252-44 · Cited by 1,083
Complications of Subclavian Vein Catheterization
Smith, B. E. (1965) · Archives of Surgery · doi:10.1001/archsurg.1965.01320080052011 · Cited by 124
The coating of intravascular plastic prostheses with colloidal graphite.
Gott, V. L., Koepke, D. E., Daggett, R. L., Zarnstorff, W. C., & Young, W. P. (1961) · PubMed · Cited by 104
Nonthrombogenic materials via a simple coating process.
Grode, G. A., Anderson, S. J., Grotta, H. M., & Falb, R. D. (1969) · PubMed · Cited by 85
Cited by
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related Infection
Maki, D. G., Weise, C. E., & Sarafin, H. W. (1977) · New England Journal of Medicine · doi:10.1056/nejm197706092962301 · Cited by 2,027
Infection Control in Intravenous Therapy
MAKI, D. G., GOLDMNAN, D. A., & RHAME, F. S. (1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-79-6-867 · Cited by 536
Liñares, J., Sitges-Serra, A., Garau, J., Pérez, J. L., & Martín, R. (1985) · Journal of Clinical Microbiology · doi:10.1128/jcm.21.3.357-360.1985 · Cited by 474
Management of occlusion and thrombosis associated with long-term indwelling central venous catheters
Baskin, J. L., Pui, C.-H., Reiss, U., Wilimas, J. A., Metzger, M. L., Ribeiro, R. C., & Howard, S. C. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60220-8 · Cited by 445
Metadata
- Authors
- Hoshal, V. L.
- Venue
- Archives of Surgery
- Publisher
- American Medical Association (AMA)
- Published
- 1971-04-01
- Volume
- 102
- Issue
- 4
- Pages
- 353
- ISSN
- 0004-0010 (ISSN-L)
- OpenAlex
- W2093134993
- Cited by
- 368
- References
- 4
- FWCI
- 24.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fibrin Sleeve Formation on Indwelling Subclavian Central Venous Catheters. https://app.cochat.ai/papers/10.1001/archsurg.1971.01350040115023
- The paper
- Hoshal, V. L. (1971). Fibrin Sleeve Formation on Indwelling Subclavian Central Venous Catheters. Archives of Surgery. https://doi.org/10.1001/archsurg.1971.01350040115023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.