Blood Pressure Measurement in Shock: Mechanism of Inaccuracy in Auscultatory and Palpatory Methods
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Arterial pressure was considerably higher than the cuff pressure obtained by auscultation or palpation of the brachial artery in 18 patients with shock and high total peripheral vascular resistance. Pulse pressure was also greatly underestimated by indirect measurement. This discrepancy was not observed in 21 hypotensive patients with low or normal resistance. Infusion of vasoconstrictor drugs into the arm circulation of normal subjects reproduced the clinical situation of normal arterial pressure with absent Korotkoff sounds and diminished radial pulses. High vascular resistance in the upper extremity prevents the hemodynamic events which normally produce the Korotkoff sounds. Disappearance of peripheral pulses is probably the result of reduced stroke volume and increased arterial wall stiffness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanical Properties of Arteries in Vivo
PETERSON, L. H., JENSEN, R. E., & PARNELL, J. (1960) · Circulation Research · doi:10.1161/01.res.8.3.622 · Cited by 679
Cited by
Surviving Sepsis Campaign: International guidelines for management of sepsis and septic shock: 2016.
Rhodes, A., Evans, L. E., Alhazzani, W., Levy, M. M., Antonelli, M., Ferrer, R., Kumar, A., Sevransky, J. E., Sprung, C. L., Nunnally, M. E., et al. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4683-6 · Cited by 6,621
“Use of an arterial cannula provides a more accurate and reproducible measurement of arterial pressure [287, 294] and also allows beatto-beat analysis so that decisions regarding therapy can be based on immediate and reproducible blood pressure information [295].”
BackgroundHemodynamic Predictors of Myocardial Oxygen Consumption During Static and Dynamic Exercise
NELSON, R. R., GOBEL, F. L., JORGENSEN, C. R., WANG, K., WANG, Y., & TAYLOR, H. L. (1974) · Circulation · doi:10.1161/01.cir.50.6.1179 · Cited by 500
Vasodilator Therapy of Cardiac Failure: (First of Two Parts)
Cohn, J. N., & Franciosa, J. A. (1977) · New England Journal of Medicine · doi:10.1056/nejm197707072970105 · Cited by 481
Self-citationAntonelli, M., Levy, M., Andrews, P. J. D., Chastre, J., Hudson, L. D., Manthous, C., Meduri, G. U., Moreno, R. P., Putensen, C., Stewart, T., et al. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0531-4 · Cited by 466
IMPROVED LEFT VENTRICULAR FUNCTION DURING NITROPRUSSIDE INFUSION IN ACUTE MYOCARDIAL INFARCTION
Franciosa, J., Limas, C., Guiha, N., Rodriguera, E., & Cohn, J. (1972) · The Lancet · doi:10.1016/s0140-6736(72)90460-6 · Cited by 452
Self-citation
Metadata
- Authors
- Cohn, J. N.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 1967-03-27
- Volume
- 199
- Issue
- 13
- Pages
- 972
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W1988923012
- Cited by
- 138
- References
- 1
- FWCI
- 13.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood Pressure Measurement in Shock: Mechanism of Inaccuracy in Auscultatory and Palpatory Methods. https://app.cochat.ai/papers/10.1001/jama.1967.03120130058009
- The paper
- Cohn, J. N. (1967). Blood Pressure Measurement in Shock: Mechanism of Inaccuracy in Auscultatory and Palpatory Methods. JAMA. https://doi.org/10.1001/jama.1967.03120130058009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.