Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 500

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Hemodynamic Predictors of Myocardial Oxygen Consumption During Static and Dynamic Exercise

Open access
NELSON, RICHARD R., GOBEL, FREDARICK L., JORGENSEN, CHARLES R., WANG, KYUHYUN, WANG, YANG, TAYLOR, HENRY L.·1974·Circulation

Abstract

Hemodynamic predictors of myocardial oxygen consumption (MVO 2 ) during static and dynamic exercise were examined in ten normal subjects. Studies were done under the following circumstances: 1) during upright bicycle exercise at an average heart rate of 147 beats/min, 2) during static exercise with an isometric load in the left hand equal to 17% of the maximal voluntary contraction (MVC), and 3) during combined dynamic exercise (average heart rate 147 beats/min) and static exercise using 17% MVC of the left hand. Mean myocardial blood flow (MBF) was 181 ml/100 gm LV/min during dynamic exercise, 98 ml/100 gm LV/min during static exercise, and 201 ml/100 gm LV/min during combined static and dynamic exercise. Addition of a static load to the dynamic load resulted in a higher blood pressure (average 12 mm Hg), MVO 2 and MBF than during dynamic exercise alone. MVO 2 correlated best with products of heart rate and blood pressure regardless of whether the blood pressure was obtained by a central aortic catheter ( r = 0.88) or by a blood pressure cuff ( r = 0.85). When the current data were combined with previous data, 82 determinations of MVO 2 and MBF in 29 normal subjects during several levels of upright exercise were available for analysis. Forty-four determinations were done during dynamic upright exercise, 18 during exercise after propranolol, ten during combined static and dynamic work, and ten during static work alone. MVO 2 correlated best with the product of heart rate and blood pressure ( r = 0.86). Heart rate alone correlated better with MVO 2 ( r = 0.82) than did the tension time index ( r = 0.65) or the product of systolic blood pressure, heart rate, and ejection time ( r = 0.68). The readily measured variables of heart rate and of heart rate x blood pressure correlated well with MVO 2 in normal young men during exercise under a wide variety of circumstances.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.50.6.1179

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 500

Metadata

Authors
NELSON, R. R., GOBEL, F. L., JORGENSEN, C. R., WANG, K., WANG, Y., & TAYLOR, H. L.
Venue
Circulation
Published
1974-12
Volume
50
Issue
6
Pages
1179-1189
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2133947263
Cited by
500
References
28
FWCI
23.79
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemodynamic Predictors of Myocardial Oxygen Consumption During Static and Dynamic Exercise. https://app.cochat.ai/papers/10.1161/01.cir.50.6.1179
The paper
NELSON, R. R., GOBEL, F. L., JORGENSEN, C. R., WANG, K., WANG, Y., & TAYLOR, H. L. (1974). Hemodynamic Predictors of Myocardial Oxygen Consumption During Static and Dynamic Exercise. Circulation. https://doi.org/10.1161/01.cir.50.6.1179

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.