CoChat

Prevalence of Tuberculin Positivity and Skin Test Anergy in HIV-1—Seropositive and —Seronegative Intravenous Drug Users

Graham, Neil M. H. · 1992 · JAMA: The Journal of the American Medical Association
Cited by 204

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: --To identify differences in purified protein derivative (PPD) tuberculin positivity and skin test anergy rates by human immunodeficiency virus (HIV) serostatus, CD4+ lymphocyte count, and other risk factors in intravenous drug users (IVDUs); and to evaluate the appropriateness of the Centers for Disease Control (CDC)--recommended definition for a positive PPD tuberculin skin test result in HIV-1-seropositive patients. DESIGN: --Nested case-control and cross-sectional analyses. SETTING: --Community-based cohort of IVDUs. PATIENTS: --Two hundred sixty HIV-1-seropositive and -seronegative IVDUs, drawn from an unselected cohort, were skin-tested for sensitivity to PPD tuberculin, mumps, and Candida antigens using the Mantoux method. OUTCOME MEASURES: --Positivity to PPD tuberculin, skin test anergy. RESULTS: --Even using the CDC definition of an induration 5 mm or greater in diameter in HIV-1 seropositives, this group was substantially less likely to be PPD tuberculin positive than HIV-1 seronegatives (13.8% vs 25.2%; P = .02). In the HIV-1 seropositives the relative odds of being PPD positive varied depending on whether 10 mm or greater (odds ratio [OR], 0.3; 95% confidence interval [CI], 0.2 to 0.7), 5 mm or greater (OR, 0.5; 95% CI, 0.2 to 0.9), or 2 mm or greater (OR, 0.7; 95% CI, 0.4 to 1.3) was used to define a positive test result. The mean diameter induration in the HIV-1-seropositive group was 2.6 mm vs 5.4 mm in the seronegative group (P = .005). Skin test anergy (to mumps and Candida) appeared to explain the differential. Anergy was substantially higher in the HIV-1 seropositive group and increased as the CD4+ lymphocyte count fell (chi 2 for linear trend, 24.5; P less than .0001). An inverse linear trend for PPD positivity and CD4+ lymphocyte count was also observed (chi 2 for trend, 6.1; P = .01). In multivariate analyses, being 35 years of age or older and being HIV-1 seronegative were significantly associated with PPD positivity, while history of previous police arrest was of borderline significance. Only HIV-1 seropositivity was significantly associated with anergy. CONCLUSIONS: --These findings show that CDC-recommended definition of an induration 5 mm or greater in diameter for PPD tuberculin positivity in HIV-1 seropositives significantly underestimates the "true" infection rate (using the PPD positivity rate in HIV-1 seronegatives as the criterion standard). A definition of 2 mm or greater would appear to be a better cutoff for reducing misclassification in HIV-1 seropositives. This study also confirms that delayed-type hypersensitivity is seriously depressed in HIV-1 seropositive IVDUs and that anergy testing is mandatory to properly assess a negative PPD test result.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.1992.03480030047035

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Graham, N. M. H.
Venue
JAMA: The Journal of the American Medical Association
Published
1992-01-15
Volume
267
Issue
3
Pages
369
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2093541334
Cited by
204
References
9
FWCI
19.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.