Examination Gloves as Barriers to Hand Contamination in Clinical Practice
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To test the effectiveness of vinyl and latex gloves as barriers to hand contamination with gram-negative organisms and enterococci during routine hospital procedures. DESIGN AND INTERVENTIONS: We studied 137 procedures during which a health care worker's gloved hand contacted a patient's mucous membrane and was thus potentially contaminated with gram-negative rods or enterococci. Quantitative hand cultures were obtained from each health care worker before and after the gloved contact using a modified glove juice method, and the exterior glove surface was also quantitatively cultured after patient contact. Used gloves were then tested for leaks using the American Society for Testing and Materials' watertight test. SETTING: Harborview Medical Center, a 330-bed city-county hospital and level I regional trauma and burn center, is both a teaching facility affiliated with the University of Washington and the major provider of care to indigent and uninsured persons in Seattle-King County, Washington. PATIENTS AND OTHER PARTICIPANTS: Respiratory therapists performing endotracheal tube care on intubated intensive care unit patients, registered nurses performing digital rectal stimulation for bowel training on patients with spinal cord injury in the rehabilitation ward, and dentists performing routine dental examinations and procedures on healthy outpatients in the dental clinic. MAIN OUTCOME MEASURE AND RESULTS: Eighty-six of the 135 gloves cultured had gram-negative rods or enterococci on the external surface after use and were thus sources of potential hand contamination. Microbial contamination of the health care worker's hands occurred in 11 (13%; 95% confidence interval, 6% to 20%) of these 86 events, and was more frequent with vinyl (10 of 42) than latex (one of 44) gloves (P < .01). After use, glove leaks were also more frequent in vinyl gloves (26 of 61) than with latex gloves (six of 70) (P < .001). Even when leaks were present, gloves prevented hand contamination in 77% of instances and quantitative counts of microorganisms contaminating hands were 2 to 4 logs less than counts on external glove surfaces. Health care workers reported awareness of the presence of glove leaks in only seven (22%) of the 32 events in which leaks were subsequently demonstrated. CONCLUSIONS: Under conditions of routine use, gloves effectively function as a protective barrier even when leaks are present. Latex gloves were less frequently associated with leaks and hand contamination. Since hand contamination occurred after 13% of exposures and cannot be readily identified by health care workers, routine hand washing should be done after each patient contact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johnson, S., Gerding, D. N., Olson, M. M., Weiler, M. D., Hughes, R. A., Clabots, C. R., & Peterson, L. R. (1990) · The American Journal of Medicine · doi:10.1016/0002-9343(90)90462-m · Cited by 317
OCCUPATIONAL EXPOSURE TO HEPATITIS B VIRUS IN HOSPITAL PERSONNEL: INFECTION OR IMMUNIZATION?
DIENSTAG, J. L., & RYAN, D. M. (1982) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a113277 · Cited by 307
Reduction of Nosocomial Infection during Pediatric Intensive Care by Protective Isolation
Klein, B. S., Perloff, W. H., & Maki, D. G. (1989) · New England Journal of Medicine · doi:10.1056/nejm198906293202603 · Cited by 189
Leakage of virus through used vinyl and latex examination gloves
Korniewicz, D. M., Laughon, B. E., Cyr, W. H., Lytle, C. D., & Larson, E. (1990) · Journal of Clinical Microbiology · doi:10.1128/jcm.28.4.787-788.1990 · Cited by 111
Implementing and evaluating a system of generic infection precautions: Body substance isolation
Lynch, P., Cummings, M. J., Roberts, P. L., Herriott, M., Yates, B., & Stamm, W. E. (1990) · American Journal of Infection Control · doi:10.1016/0196-6553(90)90204-6 · Cited by 109
Integrity of Vinyl and Latex Procedure Gloves
Korniewicz, D. M., Laughon, B. E., Butz, A. M., & Larson, E. (1989) · Nursing Research · doi:10.1097/00006199-198905000-00011 · Cited by 107
Larson, E. L., Strom, M. S., & Evans, C. A. (1980) · Journal of Clinical Microbiology · doi:10.1128/jcm.12.3.355-360.1980 · Cited by 100
Kotilainen, H. R., Brinker, J. P., Avato, J. L., & Gantz, N. M. (1989) · Archives of Internal Medicine · doi:10.1001/archinte.1989.00390120091018 · Cited by 75
Permeability of latex and vinyl gloves to water and blood
DEGROOTKOSOLCHEROERT, J., & JOAN, J. (1989) · American Journal of Infection Control · doi:10.1016/0196-6553(89)90128-4 · Cited by 57
Permeability of latex and polyvinyl chloride gloves to 20 antineoplastic drugs
Laidlaw, J. L., Connor, T. H., Theiss, J. C., Anderson, R. W., & Matney, T. S. (1984) · American Journal of Health-System Pharmacy · doi:10.1093/ajhp/41.12.2618 · Cited by 52
Cited by
Siegel, J. D., Rhinehart, E., Jackson, M., & Chiarello, L. (2007) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.10.007 · Cited by 3,456
Guideline for hand hygiene in health-care settings
Boyce, J. M., & Pittet, D. (2002) · American Journal of Infection Control · doi:10.1067/mic.2002.130391 · Cited by 2,120
Boyce, J. M., & Pittet, D. (2002) · Infection Control & Hospital Epidemiology · doi:10.1086/503164 · Cited by 1,655
Guideline for Isolation Precautions in Hospitals
Garner, J. S., & the Hospital Infection Control Practices Advisory Committee (1996) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700006123 · Cited by 994
Roter, D., & Larson, S. (2002) · Patient Education and Counseling · doi:10.1016/s0738-3991(02)00012-5 · Cited by 907
Sax, H., Allegranzi, B., Uçkay, I., Larson, E., Boyce, J., & Pittet, D. (2007) · Journal of Hospital Infection · doi:10.1016/j.jhin.2007.06.004 · Cited by 808
Pittet, D., Allegranzi, B., Boyce, J., & World Health Organization World Alliance for Patient Safety First Global Patient Safety Challenge Core Group of Experts (2009) · Infection Control & Hospital Epidemiology · doi:10.1086/600379 · Cited by 797
Evidence-based model for hand transmission during patient care and the role of improved practices
Pittet, D., Allegranzi, B., Sax, H., Dharan, S., Pessoa-Silva, C. L., Donaldson, L., & Boyce, J. M. (2006) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(06)70600-4 · Cited by 790
APIC guidelines for handwashing and hand antisepsis in health care settings
Larson, E. L. (1995) · American Journal of Infection Control · doi:10.1016/0196-6553(95)90070-5 · Cited by 771
Guidelines for Infection Control in Dental Health Care Settings
(2013) · Little and Falace's Dental Management of the Medically Compromised Patient · doi:10.1016/b978-0-323-08028-6.00032-4 · Cited by 696
Boyce, J. M., Potter-Bynoe, G., Chenevert, C., & King, T. C. (1997) · Infection Control and Hospital Epidemiology · doi:10.2307/30141488 · Cited by 673
Guideline for Isolation Precautions in Hospitals
Garner, J. S. (1996) · Infection Control and Hospital Epidemiology · doi:10.2307/30142367 · Cited by 590
(2001) · PsycEXTRA Dataset · doi:10.1037/e548302006-001 · Cited by 564
The enduring and evolving nature of the patient–physician relationship
Roter, D. (2000) · Patient Education and Counseling · doi:10.1016/s0738-3991(99)00086-5 · Cited by 529
Relationships between Enterococcal Virulence and Antimicrobial Resistance
Mundy, L. M., Sahm, D. F., & Gilmore, M. (2000) · Clinical Microbiology Reviews · doi:10.1128/cmr.13.4.513 · Cited by 500
Eggimann, P., & Pittet, D. (2001) · Chest · doi:10.1378/chest.120.6.2059 · Cited by 395
Recovery of Vancomycin-Resistant Enterococci on Fingertips and Environmental Surfaces
Noskin, G. A., Stosor, V., Cooper, I., & Peterson, L. R. (1995) · Infection Control & Hospital Epidemiology · doi:10.1086/647011 · Cited by 329
ANTIMICROBIAL RESISTANCE IN INTENSIVE CARE UNITS
Fridkin, S. K., & Gaynes, R. P. (1999) · Clinics in Chest Medicine · doi:10.1016/s0272-5231(05)70143-x · Cited by 325
Controlling Antimicrobial Resistance in Hospitals: Infection Control and Use of Antibiotics
Weinstein, R. A. (2001) · Emerging Infectious Diseases · doi:10.3201/eid0702.010206 · Cited by 275
Guideline for isolation precautions in hospitals Part I. Evolution of isolation practices
(1996) · American Journal of Infection Control · doi:10.1016/s0196-6553(96)90050-4 · Cited by 251
Guideline for hand hygiene in healthcare settings
(2004) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2003.08.016 · Cited by 243
Nosocomial Respiratory Syncytial Virus Infections: The "Cold War" Has Not Ended
Hall, C. B. (2000) · Clinical Infectious Diseases · doi:10.1086/313960 · Cited by 241
“Bacterial contamination on the hands of gloved personnel has been demonstrated [29, 31], and RSV survives on gloves for longer than on the skin of the hands [23].”
BackgroundHarpaz, R., Von Seidlein, L., Averhoff, F. M., Tormey, M. P., Sinha, S. D., Kotsopoulou, K., Lambert, S. B., Robertson, B. H., Cherry, J. D., & Shapiro, C. N. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602293340901 · Cited by 238
(2016) · Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz · doi:10.1007/s00103-016-2416-6 · Cited by 229
MAGNITUDE AND PREVENTION OF NOSOCOMIAL INFECTIONS IN THE INTENSIVE CARE UNIT
Fridkin, S. K., Welbel, S. F., & Weinstein, R. A. (1997) · Infectious Disease Clinics of North America · doi:10.1016/s0891-5520(05)70366-4 · Cited by 225
Changes in bacterial flora associated with skin damage on hands of health care personnel
Larson, E. L., Norton Hughes, C. A., Pyrek, J. D., Sparks, S. M., Cagatay, E. U., & Bartkus, J. M. (1998) · American Journal of Infection Control · doi:10.1016/s0196-6553(98)70025-2 · Cited by 220
Tenorio, A. R., Badri, S. M., Sahgal, N. B., Hota, B., Matushek, M., Hayden, M. K., Trenholme, G. M., & Weinstein, R. A. (2001) · Clinical Infectious Diseases · doi:10.1086/319214 · Cited by 210
“[8] showed that gloves prevented contamination of the hands during procedures in which exterior surfaces of the glove were contaminated with gram-negative rods or enterococci after patient care.”
BackgroundVancomycin-resistant enterococci
Murray, B. E. (1997) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)80270-8 · Cited by 205
Morgan, D. J., Liang, S. Y., Smith, C. L., Johnson, J. K., Harris, A. D., Furuno, J. P., Thorn, K. A., Snyder, G. M., Day, H. R., & Perencevich, E. N. (2010) · Infection Control & Hospital Epidemiology · doi:10.1086/653201 · Cited by 204
“The Centers for Disease of hand hygiene after wearing gloves when caring for patients Control and Prevention recommend contact precautions, in- infected with MDR gram-negative bacteria.(9) eluding the use of gloves and protective gowns, in the care In this study, we evaluated the incidence of MDR A.”
BackgroundHand Hygiene: A Frequently Missed Lifesaving Opportunity During Patient Care
Trampuz, A., & Widmer, A. F. (2004) · Mayo Clinic Proceedings · doi:10.4065/79.1.109 · Cited by 190
“21, 22 Therefore, hand hygiene is always needed after glove use and removal.”
BackgroundGlove Barriers to Bacterial Cross-Contamination between Hands to Food
Montville, R., Chen, Y., & Schaffner, D. W. (2001) · Journal of Food Protection · doi:10.4315/0362-028x-64.6.845 · Cited by 187
“In a study from the healthcare literature, hands and gloves of nurses were sampled for gram-negative rods and enterococci after performing dental, respiratory, or rectal procedures ( 21 ).”
BackgroundHandwashing and Glove Use in a Long-Term–Care Facility
Thompson, B. L., Dwyer, D. M., Ussery, X. T., Denman, S., Vacek, P., & Schwartz, B. (1997) · Infection Control & Hospital Epidemiology · doi:10.1086/647562 · Cited by 180
Strategies to Prevent Healthcare-Associated Infections through Hand Hygiene
Ellingson, K., Haas, J. P., Aiello, A. E., Kusek, L., Maragakis, L. L., Olmsted, R. N., Perencevich, E., Polgreen, P. M., Schweizer, M. L., Trexler, P., et al. (2014) · Infection Control & Hospital Epidemiology · doi:10.1086/677145 · Cited by 178
“Gloves more frequently puncture at the fingertip areas for the thumb and forefinger, reinforcing the relationship between nail length and glove puncture.(148) 4.”
Dynamics of Bacterial Hand Contamination During Routine Neonatal Care
Pessoa-Silva, C. L., Dharan, S., Hugonnet, S., Touveneau, S., Posfay-Barbe, K., Pfister, R., & Pittet, D. (2004) · Infection Control & Hospital Epidemiology · doi:10.1086/502376 · Cited by 160
“This could have been due to a smaller bacterial load on gloved hands with less hand contamination during glove removal.(27,28) Importantly, our study showed that both commensal and pathogenic bacteria accumulate on gloves during the process of care.”
Background
Metadata
- Authors
- Olsen, R. J.
- Venue
- JAMA: The Journal of the American Medical Association
- Publisher
- American Medical Association (AMA)
- Published
- 1993-07-21
- Volume
- 270
- Issue
- 3
- Pages
- 350
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2043923801
- Cited by
- 242
- References
- 10
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.