Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 182

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Determination of Deltoid Fat Pad Thickness: Implications for Needle Length in Adult Immunization

Poland, Gregory A. · 1997 · JAMA

Abstract

OBJECTIVE: To measure deltoid fat pad thickness and determine the optimal needle length for deltoid intramuscular immunization in healthy adults. DESIGN, SETTING, AND PARTICIPANTS: Prospective study of 220 healthy health care workers (126 women, 94 men) at the Mayo Medical Center, Rochester, Minn. MAIN OUTCOME MEASURES: Deltoid fat pad thickness determined by high-resolution ultrasound scanning, weight, height, and mid-deltoid arm circumference. RESULTS: We found a highly significant difference between women and men in deltoid fat pad thickness, with women having a thicker deltoid fat pad (11.7 vs 8.3 mm; P<.001). Women had a greater deltoid skin-fold thickness than men (34.7 vs 17.2 mm, P<.001) and an equal body mass index. According to the ultrasound findings, a standard 16-mm (5/8-in) needle would not have reached 5 mm into muscle in 17% (16/94) of men and 48.4% (61/126) of women in this study. CONCLUSIONS: Among healthy adults of the age range we studied, the following needle lengths appear to be appropriate for true deltoid intramuscular immunization: For men across the weight ranges we studied (59-118 kg), use of a 25-mm (1-in) needle would result in at least 5 mm of muscle penetration in all subjects. For women who weighed less than 60 kg, a 16-mm (5/8-in) needle would be sufficient to achieve muscle penetration of 5 mm. For women between 60 and 90 kg, a 25-mm (1-in) needle would be sufficient, and women greater than 90 kg would require a 38-mm (1.5-in) needle to ensure intramuscular administration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.1997.03540450065037

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Metadata

Authors
Poland, G. A.
Venue
JAMA
Published
1997-06-04
Volume
277
Issue
21
Pages
1709
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2071806902
Cited by
182
References
1
FWCI
2.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of Deltoid Fat Pad Thickness: Implications for Needle Length in Adult Immunization. https://app.cochat.ai/papers/10.1001/jama.1997.03540450065037
The paper
Poland, G. A. (1997). Determination of Deltoid Fat Pad Thickness: Implications for Needle Length in Adult Immunization. JAMA. https://doi.org/10.1001/jama.1997.03540450065037

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.