Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 184

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Association of Physician Certification and Outcomes Among Patients Receiving an Implantable Cardioverter-Defibrillator

Open access
Curtis, Jeptha P.·2009·JAMA

Abstract

CONTEXT: Allowing nonelectrophysiologists to perform implantable cardioverter-defibrillator (ICD) procedures is controversial. However, it is not known whether outcomes of ICD implantation vary by physician specialty. OBJECTIVE: To determine the association of implanting physician certification with outcomes following ICD implantation. DESIGN, SETTING, AND PATIENTS: Retrospective cohort study using cases submitted to the ICD Registry performed between January 2006 and June 2007. Patients were grouped by the certification status of the implanting physician into mutually exclusive categories: electrophysiologists, nonelectrophysiologist cardiologists, thoracic surgeons, and other specialists. Hierarchical logistic regression models were developed to determine the independent association of physician certification with outcomes. MAIN OUTCOME MEASURES: In-hospital procedural complication rates and the proportion of patients meeting criteria for a defibrillator with cardiac resynchronization therapy (CRT-D) who received that device. RESULTS: Of 111,293 ICD implantations included in the analysis, 78,857 (70.9%) were performed by electrophysiologists, 24,399 (21.9%) by nonelectrophysiologist cardiologists, 1862 (1.7%) by thoracic surgeons, and 6175 (5.5%) by other specialists. Compared with patients whose ICD was implanted by electrophysiologists, patients whose ICD was implanted by either nonelectrophysiologist cardiologists or thoracic surgeons were at increased risk of complications in both unadjusted (electrophysiologists, 3.5% [2743/78,857]; nonelectrophysiologist cardiologists, 4.0% [970/24,399]; thoracic surgeons, 5.8% [108/1862]; P < .001) and adjusted analyses (relative risk [RR] for nonelectrophysiologist cardiologists, 1.11 [95% confidence interval {CI}, 1.01-1.21]; RR for thoracic surgeons, 1.44 [95% CI, 1.15-1.79]). Among 35,841 patients who met criteria for CRT-D, those whose ICD was implanted by physicians other than electrophysiologists were significantly less likely to receive a CRT-D device compared with patients whose ICD was implanted by an electrophysiologist in both unadjusted (electrophysiologists, 83.1% [21 303/25,635]; nonelectrophysiologist cardiologists, 75.8% [5950/7849]; thoracic surgeons, 57.8% [269/465]; other specialists, 74.8% [1416/1892]; P < .001) and adjusted analyses (RR for nonelectrophysiologist cardiologists, 0.93 [95% CI, 0.91-0.95]; RR for thoracic surgeons, 0.81 [95% CI, 0.74-0.88]; RR for other specialists, 0.97 [95% CI, 0.94-0.99]). CONCLUSIONS: In this registry, nonelectrophysiologists implanted 29% of ICDs. Overall, implantations by a nonelectrophysiologist were associated with a higher risk of procedural complications and lower likelihood of receiving a CRT-D device when indicated compared with patients whose ICD was implanted by an electrophysiologist.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2009.547

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 184

Metadata

Authors
Curtis, J. P.
Venue
JAMA
Published
2009-04-22
Volume
301
Issue
16
Pages
1661
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2032419922
Cited by
184
References
5
FWCI
18.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Association of Physician Certification and Outcomes Among Patients Receiving an Implantable Cardioverter-Defibrillator. https://app.cochat.ai/papers/10.1001/jama.2009.547
The paper
Curtis, J. P. (2009). Association of Physician Certification and Outcomes Among Patients Receiving an Implantable Cardioverter-Defibrillator. JAMA. https://doi.org/10.1001/jama.2009.547

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.