Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark

Open access
Kirkfeldt, R. E., Johansen, J. B., Nohr, E. A., Jorgensen, O. D., Nielsen, J. C. · 2014 · European Heart Journal

Abstract

AIMS: Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient morbidity, healthcare costs, and possibly increased mortality. METHODS AND RESULTS: Population-based cohort study in all Danish patients who underwent a CIED procedure from May 2010 to April 2011. Data on complications were gathered on review of all patient charts while baseline data were obtained from the Danish Pacemaker and ICD Register. Adjusted risk ratios (aRRs) with 95% confidence intervals were estimated using binary regression. The study population consisted of 5918 consecutive patients. A total of 562 patients (9.5%) experienced at least one complication. The risk of any complication was higher if the patient was a female (aRR 1.3; 1.1-1.6), underweight (aRR 1.5; 1.1-2.3), implanted in a centre with an annual volume <750 procedures (0-249 procedures: aRR 1.6; 1.1-2.2, 250-499: aRR 2.0; 1.6-2.7, 500-749: aRR 1.5; 1.2-1.8), received a dual-chamber ICD (aRR 2.0; 1.4-2.7) or CRT-D (aRR 2.6; 1.9-3.4), underwent system upgrade or lead revision (aRR 1.3; 1.0-1.7), had an operator with an annual volume <50 procedures (aRR 1.9; 1.4-2.6), or underwent an emergency, out-of-hours procedure (aRR 1.5; 1.0-2.3). CONCLUSION: CIED complications are more frequent than generally acknowledged. Both patient- and procedure-related predictors may identify patients with a particularly high risk of complications. This information should be taken into account both in individual patient treatment and in the planning of future organization of CIED treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/eht511

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Risk of any complication according to procedure and CIED type (with 95% CI).
Figure 1 Risk of any complication according to procedure and CIED type (with 95% CI).CC BY-NC · PubMed Central
Figure 2 Predictors of any complication.
Figure 2 Predictors of any complication.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 871

Metadata

Authors
Kirkfeldt, R. E., Johansen, J. B., Nohr, E. A., Jorgensen, O. D., & Nielsen, J. C.
Affiliations
  • Odense University Hospital (DK)
  • Aarhus University (DK)
  • Aarhus University Hospital (DK)
Corresponding author
Kirkfeldt, R. E.
Venue
European Heart Journal
Published
2013-12-17
Volume
35
Issue
18
Pages
1186-1194
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2109817867
Cited by
871
References
33
Citations by year
2026: 68 · 2025: 73 · 2024: 68 · 2023: 84 · 2022: 94 · 2021: 66 · 2020: 71 · 2019: 68 · 2018: 92 · 2017: 74 · 2016: 46 · 2015: 50 · 2014: 16 · 2013: 1
FWCI
25.63
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • European Heart Journal (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion)
Funders
  • Hjerteforeningen
  • Aarhus Universitet
  • Aalborg Universitet
  • Odense Universitetshospital
  • Rigshospitalet
  • Aalborg Universitetshospital
  • Gangstedfonden
  • Region Midtjylland
  • Bispebjerg Hospital
  • St. Jude Medical
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Emergency Medicine › Cardiac Arrest and Resuscitation
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
Keywords
cardiac implantable electronic devices, post-implantation complications, permanent pacemaker, cardiac resynchronization therapy, CRT-D, implantable cardioverter-defibrillator, dual-chamber ICD, lead revision, system upgrade, operator volume, hospital volume, risk factors
MeSH terms
Adolescent, Adult, Aged, Aged, 80 and over, Child, Child, Preschool, Denmark, Female, Humans, Infant, Infant, Newborn, Male, Middle Aged, Pacemaker, Artificial, Postoperative Complications, Prosthesis Failure, Risk Factors, Cohort Studies, Defibrillators, Implantable, Age Distribution, Sex Distribution, Device Removal, Young Adult, Cardiac Resynchronization Therapy Devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark. https://app.cochat.ai/papers/10.1093/eurheartj/eht511
The paper
Kirkfeldt, R. E., Johansen, J. B., Nohr, E. A., Jorgensen, O. D., & Nielsen, J. C. (2014). Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark. European Heart Journal. https://doi.org/10.1093/eurheartj/eht511

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.