Estimated Radiation Dose Associated With Cardiac CT Angiography
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
CONTEXT: Cardiac computed tomography (CT) angiography (CCTA) has emerged as a useful diagnostic imaging modality in the assessment of coronary artery disease. However, the potential risks due to exposure to ionizing radiation associated with CCTA have raised concerns. OBJECTIVES: To estimate the radiation dose of CCTA in routine clinical practice as well as the association of currently available strategies with dose reduction and to identify the independent factors contributing to radiation dose. DESIGN, SETTING, AND PATIENTS: A cross-sectional, international, multicenter, observational study (50 study sites: 21 university hospitals and 29 community hospitals) of estimated radiation dose in 1965 patients undergoing CCTA between February and December 2007. Linear regression analysis was used to identify independent predictors associated with dose. MAIN OUTCOME MEASURE: Dose-length product (DLP) of CCTA. RESULTS: The median DLP of 1965 CCTA examinations performed at 50 study sites was 885 mGy x cm (interquartile range, 568-1259 mGy x cm), which corresponds to an estimated radiation dose of 12 mSv (or 1.2 x the dose of an abdominal CT study or 600 chest x-rays). A high variability in DLP was observed between study sites (range of median DLPs per site, 331-2146 mGy x cm). Independent factors associated with radiation dose were patient weight (relative effect on DLP, 5%; 95% confidence interval [CI], 4%-6%), absence of stable sinus rhythm (10%; 95% CI, 2%-19%), scan length (5%; 95% CI, 4%-6%), electrocardiographically controlled tube current modulation (-25%; 95% CI, -23% to -28%; applied in 73% of patients), 100-kV tube voltage (-46%; 95% CI, -42% to -51%; applied in 5% of patients), sequential scanning (-78%; 95% CI, -77% to -79%; applied in 6% of patients), experience in cardiac CT (-1%; 95% CI, -1% to 0%), number of CCTAs per month (0%; 95% CI, 0%-1%), and type of 64-slice CT system (for highest vs lowest dose system, 97%; 95% CI, 88%-106%). Algorithms for dose reduction were not associated with deteriorated diagnostic image quality in this observational study. CONCLUSIONS: Median doses of CCTA differ significantly between study sites and CT systems. Effective strategies to reduce radiation dose are available but some strategies are not frequently used. The comparable diagnostic image quality may support an increased use of dose-saving strategies in adequately selected patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
(2001) · Statistics for Psychologists · doi:10.4324/9781410605542-11 · Cited by 6,877
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Authors/Task Force Members (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl001 · Cited by 1,336
Hendel, R. C., Patel, M. R., Kramer, C. M., Poon, M., Hendel, R. C., Carr, J. C., Gerstad, N. A., Gillam, L. D., Hodgson, J. M., Kim, R. J., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.003 · Cited by 1,288
Mollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806
Hausleiter, J., Meyer, T., Hadamitzky, M., Huber, E., Zankl, M., Martinoff, S., Kastrati, A., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.602490 · Cited by 705
Self-citationJakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
Earls, J. P., Berman, E. L., Urban, B. A., Curry, C. A., Lane, J. L., Jennings, R. S., McCulloch, C. C., Hsieh, J., & Londt, J. H. (2008) · Radiology · doi:10.1148/radiol.2463070989 · Cited by 543
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Husmann, L., Valenta, I., Gaemperli, O., Adda, O., Treyer, V., Wyss, C. A., Veit-Haibach, P., Tatsugami, F., von Schulthess, G. K., & Kaufmann, P. A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm613 · Cited by 530
Radiation Dose in Computed Tomography of the Heart
Morin, R. L., Gerber, T. C., & McCollough, C. H. (2003) · Circulation · doi:10.1161/01.cir.0000048965.56529.c2 · Cited by 457
McCollough, C. H., & Schueler, B. A. (2000) · Medical Physics · doi:10.1118/1.598948 · Cited by 291
Coles, D. R., Smail, M. A., Negus, I. S., Wilde, P., Oberhoff, M., Karsch, K. R., & Baumbach, A. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.078 · Cited by 265
Gallagher, M. J., Ross, M. A., Raff, G. L., Goldstein, J. A., O’Neill, W. W., & O’Neil, B. J. (2006) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.06.043 · Cited by 262
(2007) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2007.05.034 · Cited by 185
The Physics of Radiology.4th ed
Laughlin, J. S. (1984) · Radiology · doi:10.1148/radiology.152.1.194 · Cited by 182
Reference Values for Diagnostic Radiology: Application and Impact
Gray, J. E., Archer, B. R., Butler, P. F., et al. (2005) · Radiology · doi:10.1148/radiol.2352020016 · Cited by 129
CT coronary angiography: where does it fit?
Carli, M. F. D. (2006) · PubMed · Cited by 8
Cited by
Smith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Writing Committee Members, Greenland, P., Alpert, J. S., Beller, G. A., Benjamin, E. J., Budoff, M. J., Fayad, Z. A., Foster, E., Hlatky, M. A., Hodgson, J. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3182051b4c · Cited by 1,873
Outcomes of Anatomical versus Functional Testing for Coronary Artery Disease
Douglas, P. S., Hoffmann, U., Patel, M. R., Mark, D. B., Al-Khalidi, H. R., Cavanaugh, B., Cole, J., Dolor, R. J., Fordyce, C. B., Huang, M., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1415516 · Cited by 1,543
Motoyama, S., Sarai, M., Harigaya, H., Anno, H., Inoue, K., Hara, T., Naruse, H., Ishii, J., Hishida, H., Wong, N. D., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.068 · Cited by 1,433
Metadata
- Authors
- Hausleiter, J.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2009-02-04
- Volume
- 301
- Issue
- 5
- Pages
- 500
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2157498742
- Cited by
- 1,000
- References
- 20
- FWCI
- 105.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.