Diagnostic Accuracy of Computed Tomographic Colonography for the Detection of Advanced Neoplasia in Individuals at Increased Risk of Colorectal Cancer
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
CONTEXT: Computed tomographic (CT) colonography has been recognized as an alternative for colorectal cancer (CRC) screening in average-risk individuals, but less information is available on its performance in individuals at increased risk of CRC. OBJECTIVE: To assess the accuracy of CT colonography in detecting advanced colorectal neoplasia in asymptomatic individuals at increased risk of CRC using unblinded colonoscopy as the reference standard. DESIGN, SETTING, AND PARTICIPANTS: This was a multicenter, cross-sectional study. Individuals at increased risk of CRC due to either family history of advanced neoplasia in first-degree relatives, personal history of colorectal adenomas, or positive results from fecal occult blood tests (FOBTs) were recruited in 11 Italian centers and 1 Belgian center between December 2004 and May 2007. Each participant underwent CT colonography followed by colonoscopy on the same day. MAIN OUTCOME MEASURES: Sensitivity and specificity of CT colonography in detecting individuals with advanced neoplasia (ie, advanced adenoma or CRC) 6 mm or larger. RESULTS: Of 1103 participants, 937 were included in the final analysis: 373 cases in the family-history group, 343 in the group with personal history of adenomas, and 221 in the FOBT-positive group. Overall, CT colonography identified 151 of 177 participants with advanced neoplasia 6 mm or larger (sensitivity, 85.3%; 95% confidence interval [CI], 79.0%-90.0%) and correctly classified results as negative for 667 of 760 participants without such lesions (specificity, 87.8%; 95% CI, 85.2%-90.0%). The positive and negative predictive values were 61.9% (95% CI, 55.4%-68.0%) and 96.3% (95% CI, 94.6%-97.5%), respectively; after group stratification, a significantly lower negative predictive value was found for the FOBT-positive group (84.9%; 95% CI, 76.2%-91.3%; P < .001). CONCLUSIONS: In a group of persons at increased risk for CRC, CT colonography compared with colonoscopy resulted in a negative predictive value of 96.3% overall. When limited to FOBT-positive persons, the negative predictive value was 84.9%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevention of Colorectal Cancer by Colonoscopic Polypectomy
Winawer, S. J., Zauber, A. G., Ho, M. N., O'Brien, M. J., Gottlieb, L. S., Sternberg, S. S., Waye, J. D., Schapiro, M., Bond, J. H., Panish, J. F., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312303292701 · Cited by 4,592
Estimates of the cancer incidence and mortality in Europe in 2006
Ferlay, J., Autier, P., Boniol, M., Heanue, M., Colombet, M., & Boyle, P. (2007) · Annals of Oncology · doi:10.1093/annonc/mdl498 · Cited by 4,036 · cited 2×
“COLORECTAL CANCER (CRC) accounts for approximately 210 000 deaths each year in Europe.(1) The majority of CRCs arise within adenomatous polyps,(2) and polypectomy is associated with a reduction in CRC incidence and mortality.”
BackgroundLevin, B., Lieberman, D. A., McFarland, B., Andrews, K. S., Brooks, D., Bond, J., Dash, C., Giardiello, F. M., Glick, S., Johnson, D., et al. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.02.002 · Cited by 2,990
VASEN, H., WATSON, P., MECKLIN, J., & LYNCH, H. (1999) · Gastroenterology · doi:10.1016/s0016-5085(99)70510-x · Cited by 2,519
WINAWER, S. (2003) · Gastroenterology · doi:10.1053/gast.2003.50044 · Cited by 2,143
Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic Adults
Pickhardt, P. J., Choi, J. R., Hwang, I., Butler, J. A., Puckett, M. L., Hildebrandt, H. A., Wong, R. K., Nugent, P. A., Mysliwiec, P. A., & Schindler, W. R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031618 · Cited by 1,972 · cited 4×
“Computed tomographic (CT) colonography has been shown to be sufficiently accurate in detecting colorectal neoplasia.(7,8) Less invasive and better tolerated than colonoscopy,(9,10) CT colonography is now considered a valid alternative for CRC screening in the general population.”
MethodResultInfluentialAccuracy of CT Colonography for Detection of Large Adenomas and Cancers
Johnson, C. D., Chen, M.-H., Toledano, A. Y., Heiken, J. P., Dachman, A., Kuo, M. D., Menias, C. O., Siewert, B., Cheema, J. I., Obregon, R. G., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800996 · Cited by 1,036 · cited 2×
“Computed tomographic (CT) colonography has been shown to be sufficiently accurate in detecting colorectal neoplasia.(7,8) Less invasive and better tolerated than colonoscopy,(9,10) CT colonography is now considered a valid alternative for CRC screening in the general population.”
MethodResultvan Rossum, L. G., van Rijn, A. F., Laheij, R. J., van Oijen, M. G., Fockens, P., van Krieken, H. H., Verbeek, A. L., Jansen, J. B., & Dekker, E. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.03.040 · Cited by 734
Cotton, P. B., Durkalski, V. L., Pineau, B. C., Palesch, Y. Y., Mauldin, P. D., Hoffman, B., Vining, D. J., Small, W. C., Affronti, J., Rex, D., et al. (2004) · JAMA · doi:10.1001/jama.291.14.1713 · Cited by 673 · cited 6×
“However, this negative aspect must be weighed against the higher dropout rate reported during colonoscopy follow-up of postpolypectomy patients.13 Here again, the better acceptance27 and lower invasiveness of CT colonography might reduce this dropout rate, thus making it an effective test for increasing in absolute te…”
BackgroundInfluentialCost-effectiveness of Screening for Colorectal Cancer in the General Population
Frazier, A. L. (2000) · JAMA · doi:10.1001/jama.284.15.1954 · Cited by 648
Rockey, D., Paulson, E., Niedzwiecki, D., Davis, W., Bosworth, H., Sanders, L., Yee, J., Henderson, J., Hatten, P., Burdick, S., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)17784-8 · Cited by 603 · cited 6×
“However, this negative aspect must be weighed against the higher dropout rate reported during colonoscopy follow-up of postpolypectomy patients.13 Here again, the better acceptance27 and lower invasiveness of CT colonography might reduce this dropout rate, thus making it an effective test for increasing in absolute te…”
InfluentialCarcinoma of the Colon and Rectum
Welch, C. E., & Burke, J. F. (1962) · New England Journal of Medicine · doi:10.1056/nejm196202012660501 · Cited by 565
Location of Adenomas Missed by Optical Colonoscopy
Pickhardt, P. J., Nugent, P. A., Mysliwiec, P. A., Choi, J. R., & Schindler, W. R. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-141-5-200409070-00009 · Cited by 446 · cited 1×
“If a polyp measuring 6 mm or larger was detected at CT colonography but not at colonoscopy, the segment was reexamined to resolve the discrepancy.(20) The duration of colonoscopy and any adverse events were recorded.”
Genetic alterations in the adenoma–carcinoma sequence
Cho, K. R., & Vogelstein, B. (1992) · Cancer · doi:10.1002/1097-0142(19920915)70:4+<1727::aid-cncr2820701613>3.0.co;2-p · Cited by 381
The Advanced Adenoma as the Primary Target of Screening
Winawer, S. J., & Zauber, A. G. (2002) · Gastrointestinal Endoscopy Clinics of North America · doi:10.1016/s1052-5157(03)00053-9 · Cited by 367
Segnan, N., Senore, C., Andreoni, B., Azzoni, A., Bisanti, L., Cardelli, A., Castiglione, G., Crosta, C., Ederle, A., Fantin, A., et al. (2007) · Gastroenterology · doi:10.1053/j.gastro.2007.03.030 · Cited by 262
Pickhardt, P. J. (2006) · Radiology · doi:10.1148/radiol.2392052002 · Cited by 225
A National Survey of Primary Care Physicians' Methods for Screening for Fecal Occult Blood
Nadel, M. R., Shapiro, J. A., Klabunde, C. N., Seeff, L. C., Uhler, R., Smith, R. A., & Ransohoff, D. F. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-142-2-200501180-00007 · Cited by 170 · cited 1×
“Despite this evidence, nonadherence to post-FOBT colonoscopy has been shown to occur in up to onethird of cases.(14) This would obviously reduce the efficacy of mass screening using FOBT.”
BackgroundLaiyemo, A. O., Murphy, G. A., Albert, P. S., Sansbury, L. B., Wang, Z., Cross, A. J., Marcus, P. M., Caan, B. J., Marshall, J. R., Lance, P., et al. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-148-6-200803180-00004 · Cited by 131 · cited 1×
“In our postpolypectomy group, the prevalence of advanced neoplasia was 11%, in line with the available literature.(29) Lower figures are observed in patients without high-risk adenomas at the index colonoscopy, but our protocol did not stratify participants according to this information.”
ResultTaylor, S. A., Halligan, S., Saunders, B. P., Bassett, P., Vance, M., & Bartram, C. I. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.4.1810913 · Cited by 126
Cottet, V., Pariente, A. E., Nalet, B., Lafon, J., Milan, C., Olschwang, S., Bonaïti‐Pellié, C., Faivre, J., & Bonithon‐Kopp, C. (2007) · Gastroenterology · doi:10.1053/j.gastro.2007.07.023 · Cited by 110 · cited 1×
“5%, which is similar to the figures reported elsewhere.(12,26) Our values of a 12% test-positive rate, 51% positive predictive value, and 82% sensitivity suggest a potentially effective use of CT colonography as an alternative to colonoscopy for screening individuals with family history of advanced colorectal neoplasi…”
ResultBujanda, L., Sarasqueta, C., Zubiaurre, L., Cosme, Á., Muñoz, C., Sánchez, A., Martín, C., Titó, L., Piñol, V., Castells, A., et al. (2007) · Gut · doi:10.1136/gut.2007.120709 · Cited by 109
Edwards, J. T., Mendelson, R., Fritschi, L., Foster, N. M., Wood, C., Murray, D., & Forbes, G. M. (2004) · Radiology · doi:10.1148/radiol.2302021422 · Cited by 99
Rapuri, S., Spencer, J., & Eckels, D. L. (2008) · International Journal of Colorectal Disease · doi:10.1007/s00384-007-0430-8 · Cited by 48 · cited 1×
“However, this negative aspect must be weighed against the higher dropout rate reported during colonoscopy follow-up of postpolypectomy patients.(13) Here again, the better acceptance(27) and lower invasiveness of CT colonography might reduce this dropout rate, thus making it an effective test for increasing in absolut…”
Background
Cited by
STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration
Cohen, J. F., Korevaar, D. A., Altman, D. G., Bruns, D. E., Gatsonis, C. A., Hooft, L., Irwig, L., Levine, D., Reitsma, J. B., de Vet, H. C. W., et al. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012799 · Cited by 2,570
Lieberman, D. A., Rex, D. K., Winawer, S. J., Giardiello, F. M., Johnson, D. A., & Levin, T. R. (2012) · Gastroenterology · doi:10.1053/j.gastro.2012.06.001 · Cited by 1,892
Guidelines for the management of iron deficiency anaemia
Goddard, A. F., James, M. W., McIntyre, A. S., & Scott, B. B. (2011) · Gut · doi:10.1136/gut.2010.228874 · Cited by 971
Colorectal Cancer: CT Colonography and Colonoscopy for Detection—Systematic Review and Meta-Analysis
Pickhardt, P. J., Hassan, C., Halligan, S., & Marmo, R. (2011) · Radiology · doi:10.1148/radiol.11101887 · Cited by 467
Rutter, M. D., East, J., Rees, C. J., Cripps, N., Docherty, J., Dolwani, S., Kaye, P. V., Monahan, K. J., Novelli, M. R., Plumb, A., et al. (2020) · Gut · doi:10.1136/gutjnl-2019-319858 · Cited by 380
Metadata
- Authors
- Regge, D.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2009-06-17
- Volume
- 301
- Issue
- 23
- Pages
- 2453
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2120087420
- Cited by
- 241
- References
- 24
- FWCI
- 14.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.