Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 673

The DOI matches its Crossref record.

Computed Tomographic Colonography (Virtual Colonoscopy): A Multicenter Comparison With Standard Colonoscopy for Detection of Colorectal Neoplasia

Cotton, Peter B., Durkalski, Valerie L., Pineau, Benoit C., Palesch, Yuko Y., Mauldin, Patrick D., Hoffman, Brenda, Vining, David J., Small, William C., Affronti, John, Rex, Douglas, Kopecky, Kenyon K., Ackerman, Susan, Burdick, J. Steven, Brewington, Cecelia, Turner, Mary A., Zfass, Alvin, Wright, Andrew R., Iyer, Revathy B., Lynch, Patrick, Sivak, Michael V., Butler, Harold·2004·JAMA

Abstract

CONTEXT: Conventional colonoscopy is the best available method for detection of colorectal cancer; however, it is invasive and not without risk. Computed tomographic colonography (CTC), also known as virtual colonoscopy, has been reported to be reasonably accurate in the diagnosis of colorectal neoplasia in studies performed at expert centers. OBJECTIVE: To assess the accuracy of CTC in a large number of participants across multiple centers. DESIGN, SETTING, AND PARTICIPANTS: A nonrandomized, evaluator-blinded, noninferiority study design of 615 participants aged 50 years or older who were referred for routine, clinically indicated colonoscopy in 9 major hospital centers between April 17, 2000, and October 3, 2001. The CTC was performed by using multislice scanners immediately before standard colonoscopy; findings at colonoscopy were reported before and after segmental unblinding to the CTC results. MAIN OUTCOME MEASURES: The sensitivity and specificity of CTC and conventional colonoscopy in detecting participants with lesions sized at least 6 mm. Secondary outcomes included detection of all lesions, detection of advanced lesions, possible technical confounders, participant preferences, and evidence for increasing accuracy with experience. RESULTS: A total of 827 lesions were detected in 308 of 600 participants who underwent both procedures; 104 participants had lesions sized at least 6 mm. The sensitivity of CTC for detecting participants with 1 or more lesions sized at least 6 mm was 39.0% (95% confidence interval [CI], 29.6%-48.4%) and for lesions sized at least 10 mm, it was 55.0% (95% CI, 39.9%-70.0%). These results were significantly lower than those for conventional colonoscopy, with sensitivities of 99.0% (95% CI, 97.1%->99.9%) and 100%, respectively. A total of 496 participants were without any lesion sized at least 6 mm. The specificity of CTC and conventional colonoscopy for detecting participants without any lesion sized at least 6 mm was 90.5% (95% CI, 87.9%-93.1%) and 100%, respectively, and without lesions sized at least 10 mm, 96.0% (95% CI, 94.3%-97.6%) and 100%, respectively. Computed tomographic colonography missed 2 of 8 cancers. The accuracy of CTC varied considerably between centers and did not improve as the study progressed. Participants expressed no clear preference for either technique. CONCLUSIONS: Computed tomographic colonography by these methods is not yet ready for widespread clinical application. Techniques and training need to be improved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.291.14.1713

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 673

Metadata

Authors
Cotton, P. B., Durkalski, V. L., Pineau, B. C., Palesch, Y. Y., Mauldin, P. D., Hoffman, B., Vining, D. J., Small, W. C., Affronti, J., Rex, D., Kopecky, K. K., Ackerman, S., Burdick, J. S., Brewington, C., Turner, M. A., Zfass, A., Wright, A. R., Iyer, R. B., Lynch, P., Sivak, M. V., & Butler, H.
Venue
JAMA
Published
2004-04-14
Volume
291
Issue
14
Pages
1713
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2144198467
Cited by
673
References
0
FWCI
43.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Computed Tomographic Colonography (Virtual Colonoscopy): A Multicenter Comparison With Standard Colonoscopy for Detection of Colorectal Neoplasia. https://app.cochat.ai/papers/10.1001/jama.291.14.1713
The paper
Cotton, P. B., Durkalski, V. L., Pineau, B. C., Palesch, Y. Y., Mauldin, P. D., Hoffman, B., Vining, D. J., Small, W. C., Affronti, J., Rex, D., Kopecky, K. K., Ackerman, S., Burdick, J. S., Brewington, C., Turner, M. A., Zfass, A., Wright, A. R., Iyer, R. B., Lynch, P., . . . Butler, H. (2004). Computed Tomographic Colonography (Virtual Colonoscopy): A Multicenter Comparison With Standard Colonoscopy for Detection of Colorectal Neoplasia. JAMA. https://doi.org/10.1001/jama.291.14.1713

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.