Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 164

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Multiple Testing, Cumulative Radiation Dose, and Clinical Indications in Patients Undergoing Myocardial Perfusion Imaging

Open access
Einstein, Andrew J., Weiner, Shepard D., Bernheim, Adam, Kulon, Michal, Bokhari, Sabahat, Johnson, Lynne L., Moses, Jeffrey W., Balter, Stephen·2010·JAMA

Abstract

CONTEXT: Myocardial perfusion imaging (MPI) is the single medical test with the highest radiation burden to the US population. Although many patients undergoing MPI receive repeat MPI testing, or additional procedures involving ionizing radiation, no data are available characterizing their total longitudinal radiation burden and relating radiation burden with reasons for testing. OBJECTIVES: To characterize procedure counts, cumulative estimated effective doses of radiation, and clinical indications for patients undergoing MPI. DESIGN, SETTING, AND PATIENTS: A retrospective cohort study of 1097 consecutive patients undergoing index MPI during the first 100 days of 2006 (January 1-April 10) at Columbia University Medical Center, New York, New York, that evaluated all preceding medical imaging procedures involving ionizing radiation undergone beginning October 1988, and all subsequent procedures through June 2008, at the center. MAIN OUTCOME MEASURES: Cumulative estimated effective dose of radiation, number of procedures involving radiation, and indications for testing. RESULTS: Patients underwent a median of 15 (interquartile range [IQR], 6-32; mean, 23.9) procedures involving radiation exposure; of which 4 (IQR, 2-8; mean, 6.5) were high-dose procedures (≥3 mSv; ie, 1 year's background radiation), including 1 (IQR, 1-2; mean, 1.8) MPI study per patient. A total of 344 patients (31.4%) received cumulative estimated effective dose from all medical sources of more than 100 mSv. Multiple MPIs were performed in 424 patients (38.6%), for whom cumulative estimated effective dose was 121 mSv (IQR, 81-189; mean, 149 mSv). Men and white patients had higher cumulative estimated effective doses. More than 80% of initial and 90% of repeat MPI examinations were performed in patients with known cardiac disease or symptoms consistent with it. CONCLUSION: In this institution, multiple testing with MPI was common and in many patients associated with high cumulative estimated doses of radiation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2010.1664

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 164

Metadata

Authors
Einstein, A. J., Weiner, S. D., Bernheim, A., Kulon, M., Bokhari, S., Johnson, L. L., Moses, J. W., & Balter, S.
Venue
JAMA
Published
2010-11-17
Volume
304
Issue
19
Pages
2137
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2016330730
Cited by
164
References
2
FWCI
15.43
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiple Testing, Cumulative Radiation Dose, and Clinical Indications in Patients Undergoing Myocardial Perfusion Imaging. https://app.cochat.ai/papers/10.1001/jama.2010.1664
The paper
Einstein, A. J., Weiner, S. D., Bernheim, A., Kulon, M., Bokhari, S., Johnson, L. L., Moses, J. W., & Balter, S. (2010). Multiple Testing, Cumulative Radiation Dose, and Clinical Indications in Patients Undergoing Myocardial Perfusion Imaging. JAMA. https://doi.org/10.1001/jama.2010.1664

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.