Multiple Testing, Cumulative Radiation Dose, and Clinical Indications in Patients Undergoing Myocardial Perfusion Imaging
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
CONTEXT: Myocardial perfusion imaging (MPI) is the single medical test with the highest radiation burden to the US population. Although many patients undergoing MPI receive repeat MPI testing, or additional procedures involving ionizing radiation, no data are available characterizing their total longitudinal radiation burden and relating radiation burden with reasons for testing. OBJECTIVES: To characterize procedure counts, cumulative estimated effective doses of radiation, and clinical indications for patients undergoing MPI. DESIGN, SETTING, AND PATIENTS: A retrospective cohort study of 1097 consecutive patients undergoing index MPI during the first 100 days of 2006 (January 1-April 10) at Columbia University Medical Center, New York, New York, that evaluated all preceding medical imaging procedures involving ionizing radiation undergone beginning October 1988, and all subsequent procedures through June 2008, at the center. MAIN OUTCOME MEASURES: Cumulative estimated effective dose of radiation, number of procedures involving radiation, and indications for testing. RESULTS: Patients underwent a median of 15 (interquartile range [IQR], 6-32; mean, 23.9) procedures involving radiation exposure; of which 4 (IQR, 2-8; mean, 6.5) were high-dose procedures (≥3 mSv; ie, 1 year's background radiation), including 1 (IQR, 1-2; mean, 1.8) MPI study per patient. A total of 344 patients (31.4%) received cumulative estimated effective dose from all medical sources of more than 100 mSv. Multiple MPIs were performed in 424 patients (38.6%), for whom cumulative estimated effective dose was 121 mSv (IQR, 81-189; mean, 149 mSv). Men and white patients had higher cumulative estimated effective doses. More than 80% of initial and 90% of repeat MPI examinations were performed in patients with known cardiac disease or symptoms consistent with it. CONCLUSION: In this institution, multiple testing with MPI was common and in many patients associated with high cumulative estimated doses of radiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748 · cited 5×
“5 (6-31) [1-166] 16 (6-30) [1-159] 15 (6-29) [1-193] .”
InfluentialSontrop, J. M., Dixon, S. N., Garg, A. X., Buendia-Jimenez, I., Dohein, O., Huang, S.-H. S., & Clark, W. F. (2013) · American Journal of Nephrology · doi:10.1159/000350377 · Cited by 5,871
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Health Risks from Exposure to Low Levels of Ionizing Radiation:: BEIR VII Phase 2
Earth, D. O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,190
RE:“;THE IMPACT OF CONFOUNDER SELECTION CRITERIA ON EFFECT ESTIMATION”
Greenland, S., & Mickey, R. M. (1989) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a115409 · Cited by 2,108
Preface, Executive Summary and Glossary
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.10.003 · Cited by 2,106
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Shaw, L. J., Berman, D. S., Maron, D. J., Mancini, G. B. J., Hayes, S. W., Hartigan, P. M., Weintraub, W. S., O’Rourke, R. A., Dada, M., Spertus, J. A., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.743963 · Cited by 1,605
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410 · cited 5×
“5 (6-31) [1-166] 16 (6-30) [1-159] 15 (6-29) [1-193] .”
InfluentialSelf-citationBenefits and costs, an eternal balance
Dixon, A. K. (2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.09.001 · Cited by 1,355
Cited by
Erbel (2014) · doi:10.1093/eurheartj/ehu281 · Cited by 4,451
Pellikka, P. A., Arruda-Olson, A., Chaudhry, F. A., Chen, M. H., Marshall, J. E., Porter, T. R., & Sawada, S. G. (2020) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.07.001 · Cited by 583
2014 ESC Guidelines on the diagnosis and treatment of aortic diseases
Erbel, R., Aboyans, V., Boileau, C., Bossone, E., Di Bartolomeo, R., Eggebrecht, H., Evangelista, A., Falk, V., Frank, H., Gaemperli, O., et al. (2014) · Kardiologia Polska · doi:10.5603/kp.2014.0225 · Cited by 458
Picano, E., Vano, E., Rehani, M. M., Cuocolo, A., Mont, L., Bodi, V., Bar, O., Maccia, C., Pierard, L., Sicari, R., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht394 · Cited by 361
Kones, R. (2011) · Drug Design, Development and Therapy · doi:10.2147/dddt.s14934 · Cited by 259
Minimizing and Communicating Radiation Risk in Pediatric Nuclear Medicine
Fahey, F. H., Treves, S. T., & Adelstein, S. J. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069609 · Cited by 165
Metadata
- Authors
- Einstein, A. J., Weiner, S. D., Bernheim, A., Kulon, M., Bokhari, S., Johnson, L. L., Moses, J. W., & Balter, S.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2010-11-17
- Volume
- 304
- Issue
- 19
- Pages
- 2137
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2016330730
- Cited by
- 164
- References
- 37
- FWCI
- 15.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.