The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Effect of Biolimus-Eluting Stents With Biodegradable Polymer vs Bare-Metal Stents on Cardiovascular Events Among Patients With Acute Myocardial Infarction: The COMFORTABLE AMI Randomized Trial
Abstract
CONTEXT: The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). OBJECTIVE: To compare stents eluting biolimus from a biodegradable polymer with bare-metal stents in primary PCI. DESIGN, SETTING, AND PATIENTS: A prospective, randomized, single-blinded, controlled trial of 1161 patients presenting with STEMI at 11 sites in Europe and Israel between September 19, 2009, and January 25, 2011. Clinical follow-up was performed at 1 and 12 months. INTERVENTION: Patients were randomized 1:1 to receive the biolimus-eluting stent (n = 575) or the bare-metal stent (n = 582). MAIN OUTCOME MEASURES: Primary end point was the rate of major adverse cardiac events, a composite of cardiac death, target vessel-related reinfarction, and ischemia-driven target-lesion revascularization at 1 year. RESULTS: Major adverse cardiac events at 1 year occurred in 24 patients (4.3%) receiving biolimus-eluting stents with biodegradable polymer and 49 patients (8.7%) receiving bare-metal stents (hazard ratio [HR], 0.49; 95% CI, 0.30-0.80; P = .004). The difference was driven by a lower risk of target vessel-related reinfarction (3 [0.5%] vs 15 [2.7%]; HR, 0.20; 95% CI, 0.06-0.69; P = .01) and ischemia-driven target-lesion revascularization (9 [1.6%] vs 32 [5.7%]; HR, 0.28; 95% CI, 0.13-0.59; P < .001) in patients receiving biolimus-eluting stents compared with those receiving bare-metal stents. Rates of cardiac death were not significantly different (16 [2.9%] vs 20 [3.5%], P = .53). Definite stent thrombosis occurred in 5 patients (0.9%) treated with biolimus-eluting stents and 12 patients (2.1%; HR, 0.42; 95% CI, 0.15-1.19; P = .10) treated with bare-metal stents. CONCLUSION: Compared with a bare-metal stent, the use of biolimus-eluting stents with a biodegradable polymer resulted in a lower rate of the composite of major adverse cardiac events at 1 year among patients with STEMI undergoing primary PCI. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00962416.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Developed with the special contribution of the European Association for Percutaneous Cardiovascular Interventions (EAPCI), Authors/Task Force Members, Wijns, W., Kolh, P., Danchin, N., Di Mario, C., Falk, V., Folliguet, T., Garg, S., Huber, K., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq277 · Cited by 3,184
Self-citationPathology of the Vulnerable Plaque
Virmani, R., Burke, A. P., Farb, A., & Kolodgie, F. D. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.065 · Cited by 2,315
Platelet Activation and Atherothrombosis
Davì, G., & Patrono, C. (2007) · New England Journal of Medicine · doi:10.1056/nejmra071014 · Cited by 2,135
A Comparison of Immediate Angioplasty with Thrombolytic Therapy for Acute Myocardial Infarction
Grines, C. L., Browne, K. F., Marco, J., Rothbaum, D., Stone, G. W., O'Keefe, J., Overlie, P., Donohue, B., Chelliah, N., Timmis, G. C., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303113281001 · Cited by 1,995
Daemen, J., Wenaweser, P., Tsuchida, K., Abrecht, L., Vaina, S., Morger, C., Kukreja, N., Jüni, P., Sianos, G., Hellige, G., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60314-6 · Cited by 1,757
Self-citationZijlstra, F., de Boer, M. J., Hoorntje, J., Reiffers, S., Reiber, J., & Suryapranata, H. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303113281002 · Cited by 1,290
Comparison of Angioplasty with Stenting, with or without Abciximab, in Acute Myocardial Infarction
Stone, G. W., Grines, C. L., Cox, D. A., Garcia, E., Tcheng, J. E., Griffin, J. J., Guagliumi, G., Stuckey, T., Turco, M., Carroll, J. D., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013404 · Cited by 1,277
Montalescot, G., Wiviott, S. D., Braunwald, E., Murphy, S. A., Gibson, C. M., McCabe, C. H., & Antman, E. M. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60441-4 · Cited by 1,068
Coronary Angioplasty with or without Stent Implantation for Acute Myocardial Infarction
Grines, C. L., Cox, D. A., Stone, G. W., Garcia, E., Mattos, L. A., Giambartolomei, A., Brodie, B. R., Madonna, O., Eijgelshoven, M., Lansky, A. J., et al. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912233412601 · Cited by 946
Vlaar, P. J., Svilaas, T., van der Horst, I. C., Diercks, G. F., Fokkema, M. L., de Smet, B. J., van den Heuvel, A. F., Anthonio, R. L., Jessurun, G. A., Tan, E.-S., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60833-8 · Cited by 900
Cited by
Ibanez, B., James, S., Agewall, S., Antunes, M. J., Bucciarelli-Ducci, C., Bueno, H., Caforio, A. L. P., Crea, F., Goudevenos, J. A., Halvorsen, S., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx393 · Cited by 9,728
Self-citationRoffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
Self-citation2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
Self-citation2023 ESC Guidelines for the management of acute coronary syndromes
Byrne, R. A., Rossello, X., Coughlan, J. J., Barbato, E., Berry, C., Chieffo, A., Claeys, M. J., Dan, G.-A., Dweck, M. R., Galbraith, M., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad191 · Cited by 5,333
Self-citation(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
Metadata
- Authors
- Räber, L., Kelbæk, H., Ostojic, M., Baumbach, A., Heg, D., Tüller, D., von Birgelen, C., Roffi, M., Moschovitis, A., Khattab, A. A., Wenaweser, P., Bonvini, R., Pedrazzini, G., Kornowski, R., Weber, K., Trelle, S., Lüscher, T. F., Taniwaki, M., Matter, C. M., Meier, B., Jüni, P., Windecker, S., & COMFORTABLE AMI Trial Investigators, F. T.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2012-08-22
- Volume
- 308
- Issue
- 8
- Pages
- 777
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2043438355
- Cited by
- 298
- References
- 29
- FWCI
- 44.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Biolimus-Eluting Stents With Biodegradable Polymer vs Bare-Metal Stents on Cardiovascular Events Among Patients With Acute Myocardial Infarction: The COMFORTABLE AMI Randomized Trial. https://app.cochat.ai/papers/10.1001/jama.2012.10065
- The paper
- Räber, L., Kelbæk, H., Ostojic, M., Baumbach, A., Heg, D., Tüller, D., von Birgelen, C., Roffi, M., Moschovitis, A., Khattab, A. A., Wenaweser, P., Bonvini, R., Pedrazzini, G., Kornowski, R., Weber, K., Trelle, S., Lüscher, T. F., Taniwaki, M., Matter, C. M., . . . COMFORTABLE AMI Trial Investigators, F. T. (2012). Effect of Biolimus-Eluting Stents With Biodegradable Polymer vs Bare-Metal Stents on Cardiovascular Events Among Patients With Acute Myocardial Infarction: The COMFORTABLE AMI Randomized Trial. JAMA. https://doi.org/10.1001/jama.2012.10065
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.