The DOI matches its Crossref record.
Surveillance Intervals for Small Abdominal Aortic Aneurysms: A Meta-analysis
Open accessAbstract
IMPORTANCE: Small abdominal aortic aneurysms (AAAs [3.0 cm-5.4 cm in diameter]) are monitored by ultrasound surveillance. The intervals between surveillance scans should be chosen to detect an expanding aneurysm prior to rupture. OBJECTIVE: To limit risk of aneurysm rupture or excessive growth by optimizing ultrasound surveillance intervals. DATA SOURCES AND STUDY SELECTION: Individual patient data from studies of small AAA growth and rupture were assessed. Studies were identified for inclusion through a systematic literature search through December 2010. Study authors were contacted, which yielded 18 data sets providing repeated ultrasound measurements of AAA diameter over time in 15,471 patients. DATA EXTRACTION: AAA diameters were analyzed using a random-effects model that allowed for between-patient variability in size and growth rate. Rupture rates were analyzed by proportional hazards regression using the modeled AAA diameter as a time-varying covariate. Predictions of the risks of exceeding 5.5-cm diameter and of rupture within given time intervals were estimated and pooled across studies by random effects meta-analysis. RESULTS: AAA growth and rupture rates varied considerably across studies. For each 0.5-cm increase in AAA diameter, growth rates increased on average by 0.59 mm per year (95% CI, 0.51-0.66) and rupture rates increased by a factor of 1.91 (95% CI, 1.61-2.25). For example, to control the AAA growth risk in men of exceeding 5.5 cm to below 10%, on average, a 7.4-year surveillance interval (95% CI, 6.7-8.1) is sufficient for a 3.0-cm AAA, while an 8-month interval (95% CI, 7-10) is necessary for a 5.0-cm AAA. To control the risk of rupture in men to below 1%, the corresponding estimated surveillance intervals are 8.5 years (95% CI, 7.0-10.5) and 17 months (95% CI, 14-22). CONCLUSION AND RELEVANCE: In contrast to the commonly adopted surveillance intervals in current AAA screening programs, surveillance intervals of several years may be clinically acceptable for the majority of patients with small AAA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Erbel (2014) · doi:10.1093/eurheartj/ehu281 · Cited by 4,451
Chaikof, E. L., Dalman, R. L., Eskandari, M. K., Jackson, B. M., Lee, W. A., Mansour, M. A., Mastracci, T. M., Mell, M., Murad, M. H., Nguyen, L. L., et al. (2018) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2017.10.044 · Cited by 2,751
Wanhainen, A., Verzini, F., Van Herzeele, I., Allaire, E., Bown, M., Cohnert, T., Dick, F., van Herwaarden, J., Karkos, C., Koelemay, M., et al. (2019) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2018.09.020 · Cited by 2,326
Isselbacher, E. M., Preventza, O., Hamilton Black, J., Augoustides, J. G., Beck, A. W., Bolen, M. A., Braverman, A. C., Bray, B. E., Brown-Zimmerman, M. M., Chen, E. P., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001106 · Cited by 2,082
Wanhainen, A., Van Herzeele, I., Bastos Goncalves, F., Bellmunt Montoya, S., Berard, X., Boyle, J. R., D’Oria, M., Prendes, C. F., Karkos, C. D., Kazimierczak, A., et al. (2024) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2023.11.002 · Cited by 1,207
Metadata
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2013-02-27
- Volume
- 309
- Issue
- 8
- Pages
- 806
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W1868557119
- Cited by
- 251
- References
- 0
- FWCI
- 14.86
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surveillance Intervals for Small Abdominal Aortic Aneurysms: A Meta-analysis. https://app.cochat.ai/papers/10.1001/jama.2013.950
- The paper
- Surveillance Intervals for Small Abdominal Aortic Aneurysms: A Meta-analysis. (2013). JAMA. https://doi.org/10.1001/jama.2013.950
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.