Comparison of Vascular Closure Devices vs Manual Compression After Femoral Artery Puncture: The ISAR-CLOSURE Randomized Clinical Trial
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: The role of vascular closure devices (VCD) for the achievement of hemostasis in patients undergoing transfemoral coronary angiography remains controversial. OBJECTIVE: To compare outcomes with the use of 2 hemostasis strategies after diagnostic coronary angiography performed via transfemoral access-a VCD-based strategy with 2 types of devices, an intravascular device and an extravascular device, vs standard manual compression. The primary hypothesis to be tested was that femoral hemostasis achieved through VCD is noninferior to manual compression in terms of vascular access-site complications. A secondary objective was the comparison of the 2 types of VCD. DESIGN, SETTING, AND PARTICIPANTS: Randomized, large-scale, multicenter, open-label clinical trial. We enrolled 4524 patients undergoing coronary angiography with a 6 French sheath via the common femoral artery from April 2011 through May 2014 in 4 centers in Germany. Last 30-day follow-up was performed in July 2014. INTERVENTIONS: After angiography of the access site, patients were randomized to hemostasis with an intravascular VCD, extravascular VCD, or manual compression in a 1:1:1 ratio. MAIN OUTCOMES AND MEASURES: Primary end point: the composite of access site-related vascular complications at 30 days after randomization with a 2% noninferiority margin. Secondary end points: time to hemostasis, repeat manual compression, and VCD failure. An α-level of .025 was chosen for primary and secondary comparisons. RESULTS: Of the 4524 enrolled patients, 3015 were randomly assigned to a VCD group (1509 received intravascular VCD and 1506 received extravascular VCD) and 1509 patients were randomly assigned to the manual compression group. Before hospital discharge, duplex sonography of the access site was performed in 4231 (94%) patients. The primary end point was observed in 208 patients (6.9%) assigned to receive a VCD and 119 patients (7.9%) assigned to manual compression (difference, -1.0% [1-sided 97.5% CI, 0.7%]; P for noninferiority<.001). Time to hemostasis was significantly shorter in patients with VCD (1 minute [interquartile range {IQR}, 0.5-2.0]), vs manual compression (10 minutes [IQR, 10-15]; P < .001). Time to hemostasis was significantly shorter among patients with intravascular VCD (0.5 minute [IQR, 0.2-1.0]), vs extravascular VCD (2.0 minutes [IQR, 1.0-2.0]; P <.001) and closure device failure was also significantly lower among those with intravascular vs extravascular VCD (80 patients [5.3%], vs 184 patients [12.2%]; P < .001). CONCLUSIONS AND RELEVANCE: In patients undergoing transfemoral coronary angiography, VCDs were noninferior to manual compression in terms of vascular access-site complications and reduced time to hemostasis. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01389375.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Adequate hemostasis was defined by Schulz-Schüpke et al. [21].”
In the citing paper
“These results are not very dissimilar from the failure rates of VCDs reported in the current literature (1.1–8.7%) [11,14,15,16,17,21,23].”
In the citing paper
“6.7% of bleeding-related VASCs in the VCD group and 8.5% of bleeding-related VASCs in the MC group were noted by Schulz-Schüpke et al. [21].”
In the citing paper
“the technical failure of VCDs is around 1.1–8.7% [11,14,15,16,17,21,23].”
In the citing paper
“the incidence of vascular access site complications (VASCs) remains between 5% and 12% [11,13,14,15,16,17,18,19,20,21,22].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jolly, S. S., Yusuf, S., Cairns, J., Niemelä, K., Xavier, D., Widimsky, P., Budaj, A., Niemelä, M., Valentin, V., Lewis, B. S., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60404-2 · Cited by 2,125
Koreny, M., Riedmüller, E., Nikfardjam, M., Siostrzonek, P., & Müllner, M. (2004) · JAMA · doi:10.1001/jama.291.3.350 · Cited by 559
Nikolsky, E., Mehran, R., Halkin, A., Aymong, E. D., Mintz, G. S., Lasic, Z., Negoita, M., Fahy, M., Krieger, S., Moussa, I., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.06.048 · Cited by 439
Lincoff, A. M. (2004) · JAMA · doi:10.1001/jama.292.6.696 · Cited by 401
Biancari, F., D’Andrea, V., Marco, C. D., Savino, G., Tiozzo, V., & Catania, A. (2010) · American Heart Journal · doi:10.1016/j.ahj.2009.12.027 · Cited by 287
Dauerman, H. L., Applegate, R. J., & Cohen, D. J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.07.028 · Cited by 210
Lincoff, A. M., Kleiman, N. S., Dj, K., Feit, F., Bittl, J. A., Jackman, J. D., Ij, S., Cohen, D., Spriggs, D., Ebrahimi, R., et al. (2006) · Cited by 77
Holm, N. R., Sindberg, B., Schou, M., Mæng, M., Kaltoft, A., Bøttcher, M., Krusell, L. R., Hjort, J., Thuesen, L., Terkelsen, C. J., et al. (2014) · EuroIntervention · doi:10.4244/eijv10i2a31 · Cited by 72
Vascular access and closure in coronary angiography and percutaneous intervention
Byrne, R. A., Cassese, S., Linhardt, M., & Kastrati, A. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2012.160 · Cited by 53
Self-citationXhepa, E., Byrne, R. A., Schulz, S., Helde, S., Gewalt, S., Cassese, S., Linhardt, M., Ibrahim, T., Mehilli, J., Hoppe, K., et al. (2014) · EuroIntervention · doi:10.4244/eijv10i2a33 · Cited by 12
Self-citation
Cited by
Items 201–226 of 226
A Case of Huge Scrotal Hematoma during Mechanical Thrombectomy
Tsurusaki, Y., Sakaï, S., Morita, T., Miki, K., Inoue, D., Haga, S., & Arihiro, S. (2022) · Journal of Neuroendovascular Therapy · doi:10.5797/jnet.cr.2022-0049
Huang, Y.-C., Kao, C.-C., Lu, Y., Chou, Y., Lin, Y., & Tam, K. (2023) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2023.01.001
Lee, S. H., Kim, D. R., Lee, J. S., Nam, I. C., & Ko, S. Y. (2023) · Journal of the Korean Society of Radiology · doi:10.3348/jksr.2022.0100
Desai, K. R. (2023) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2023.07.011
Pediatric Interventional Neuroradiology: “How I Do It” v. I – Diagnostic Angiography
Jones, J. G. A., & Deveikis, J. P. (2024) · Interventional Neuroradiology · doi:10.1177/15910199241255154
Giorgio, A. D., Carnuccio, C., Nesci, A., D’Alessandro, A., & Santoliquido, A. (2024) · The Journal of Vascular Access · doi:10.1177/11297298241254255
Tecniche di base in chirurgia endovascolare
Mercier, L., & Coscas, R. (2024) · EMC - Tecniche Chirurgiche Vascolare · doi:10.1016/s1283-0801(24)49394-1
Badani, R. S., & Kalia, A. (2024) · IHJ Cardiovascular Reports · doi:10.1016/j.ihjcvr.2024.10.009
Mastrorilli, D., Forcella, E., Miccoli, T., Massari, C. D., & Garriboli, L. (2024) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2024.12.040
Gouëffic, Y., Deloose, K. R., Dubosq‐Lebaz, M., & Zeller, T. (2025) · CVIR Endovascular · doi:10.1186/s42155-025-00522-5
Ahmad, K., Khan, S., Gadey, G., & Piemonte, T. C. (2025) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.70409
Okusako, R., Kobayashi, T., Okazaki, T., Hamamoto, M., & Takahashi, S. (2025) · Vascular and Endovascular Surgery · doi:10.1177/15385744251409971
Baron, S. (2021) · heiDOK (Heidelberg University) · doi:10.11588/heidok.00030016
Cebrián, J. P. (2017) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Rao, S., Nolan, J., Fraser, D., Mamas, M. A., Bertrand, O., Pancholy, S., Bernát, I., Dharma, S., Kedev, S., Jolly, S., et al. (2015) · Keele Research Repository (Keele University)
Simelius-Nieminen, S. (2018) · Theseus (Ammattikorkeakoulujen)
Helde, S., Kastrati, A., & München, T. U. (2021) · mediaTUM (Technical University of Munich)
Self-citationMeijers, T. A. (2024) · Radboud Repository (Radboud University)
Dias, I. C. N., Teivelis, M. P., Cucato, G. G., Nasser, F., Burihan, M. C., & Neto, H. J. G. (2025) · Jornal Vascular Brasileiro · doi:10.1590/1677-5449.202400652
Šliuburytė, E. (2021) · Lithuanian University of Health Sciences
Usman, F. S., Rahman, A., Medikanto, A. R., Irawan, E., Leksono, A. B. B., Kastilong, M. P., & Kurnia, L. (2026) · Journal of Neurointervention and Stroke · doi:10.63937/jnevis-2026.21.28
Goulianou, A., Sabharwal, T., Shahzad, I., Gkoutzios, P., Ahmed, I., Thulasidasan, N., Thomson, B., Lechareas, S., & Διαμαντόπουλος, Α. (2026) · Expert Review of Medical Devices · doi:10.1080/17434440.2026.2689669
Groin punctures and their complications
Kotkavuori, L. (2023) · UEF eRepo (University of Eastern Finland)
Lavin, W., & Klinungkab, K. (2021) · Journal of Nursing Science and Health
Kat, N. K., & Setayeshi, T. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15218242
Liu, X., Guo, Y., Guangyuan, S., Chen, T., 安贵鹏, Wang, L., Guo, Y., Zhou, H., Jiang, L., Chen, X., et al. (2026) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2026.10.055
Metadata
- Authors
- Schulz-Schüpke, S., Helde, S., Gewalt, S., Ibrahim, T., Linhardt, M., Haas, K., Hoppe, K., Böttiger, C., Groha, P., Bradaric, C., Schmidt, R., Bott-Flügel, L., Ott, I., Goedel, J., Byrne, R. A., Schneider, S., Burgdorf, C., Morath, T., Kufner, S., Joner, M., Cassese, S., Hoppmann, P., Hengstenberg, C., Pache, J., Fusaro, M., Massberg, S., Mehilli, J., Schunkert, H., Laugwitz, K.-L., & Kastrati, A.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2014-11-19
- Volume
- 312
- Issue
- 19
- Pages
- 1981
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W1980351258
- Cited by
- 198
- References
- 11
- FWCI
- 14.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.