Comparison of Balloon-Expandable vs Self-expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement: The CHOICE Randomized Clinical Trial

Abdel-Wahab, Mohamed, Mehilli, Julinda, Frerker, Christian, Neumann, Franz-Josef, Kurz, Thomas, Tölg, Ralph, Zachow, Dirk, Guerra, Elena, Massberg, Steffen, Schäfer, Ulrich, El-Mawardy, Mohamed, Richardt, Gert·2014·JAMA

Abstract

IMPORTANCE: Transcatheter aortic valve replacement (TAVR) is an effective treatment option for high-risk patients with severe aortic stenosis. Different from surgery, transcatheter deployment of valves requires either a balloon-expandable or self-expandable system. A randomized comparison of these 2 systems has not been performed. OBJECTIVE: To determine whether the balloon-expandable device is associated with a better success rate than the self-expandable device. DESIGN, SETTING, AND PATIENTS: The CHOICE study was an investigator-initiated trial in high-risk patients with severe aortic stenosis and an anatomy suitable for the transfemoral TAVR procedure. One hundred twenty-one patients were randomly assigned to receive a balloon-expandable valve (Edwards Sapien XT) and 120 were assigned to receive a self-expandable valve (Medtronic CoreValve). Patients were enrolled between March 2012 and December 2013 at 5 centers in Germany. INTERVENTIONS: Transfemoral TAVR with a balloon-expandable or self-expandable device. MAIN OUTCOMES AND MEASURES: The primary end point was device success, which is a composite end point including successful vascular access and deployment of the device and retrieval of the delivery system, correct position of the device, intended performance of the heart valve without moderate or severe regurgitation, and only 1 valve implanted in the proper anatomical location. Secondary end points included cardiovascular mortality, bleeding and vascular complications, postprocedural pacemaker placement, and a combined safety end point at 30 days, including all-cause mortality, major stroke, and other serious complications. RESULTS: Device success occurred in 116 of 121 patients (95.9%) in the balloon-expandable valve group and 93 of 120 patients (77.5%) in the self-expandable valve group (relative risk [RR], 1.24, 95% CI, 1.12-1.37, P < .001). This was attributed to a significantly lower frequency of residual more-than-mild aortic regurgitation (4.1% vs 18.3%; RR, 0.23; 95% CI, 0.09-0.58; P < .001) and the less frequent need for implanting more than 1 valve (0.8% vs 5.8%, P = .03) in the balloon-expandable valve group. Cardiovascular mortality at 30 days was 4.1% in the balloon-expandable valve group and 4.3% in the self-expandable valve group (RR, 0.97; 95% CI, 0.29-3.25; P = .99). Bleeding and vascular complications were not significantly different, and the combined safety end point occurred in 18.2% of those in the balloon-expandable valve group and 23.1% of the self-expandable valve group (RR, 0.79; 95% CI, 0.48-1.30; P = .42). Placement of a new permanent pacemaker was less frequent in the balloon-expandable valve group (17.3% vs 37.6%, P = .001). CONCLUSIONS AND RELEVANCE: Among patients with high-risk aortic stenosis undergoing TAVR, the use of a balloon-expandable valve resulted in a greater rate of device success than use of a self-expandable valve. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01645202.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2014.3316

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Cited by

See all 686

Metadata

Authors
Abdel-Wahab, M., Mehilli, J., Frerker, C., Neumann, F.-J., Kurz, T., Tölg, R., Zachow, D., Guerra, E., Massberg, S., Schäfer, U., El-Mawardy, M., & Richardt, G.
Venue
JAMA
Published
2014-04-16
Volume
311
Issue
15
Pages
1503
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2107912271
Cited by
686
References
37
FWCI
58.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Balloon-Expandable vs Self-expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement: The CHOICE Randomized Clinical Trial. https://app.cochat.ai/papers/10.1001/jama.2014.3316
The paper
Abdel-Wahab, M., Mehilli, J., Frerker, C., Neumann, F.-J., Kurz, T., Tölg, R., Zachow, D., Guerra, E., Massberg, S., Schäfer, U., El-Mawardy, M., & Richardt, G. (2014). Comparison of Balloon-Expandable vs Self-expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement: The CHOICE Randomized Clinical Trial. JAMA. https://doi.org/10.1001/jama.2014.3316

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.