The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Comparison of Balloon-Expandable vs Self-expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement: The CHOICE Randomized Clinical Trial
Abstract
IMPORTANCE: Transcatheter aortic valve replacement (TAVR) is an effective treatment option for high-risk patients with severe aortic stenosis. Different from surgery, transcatheter deployment of valves requires either a balloon-expandable or self-expandable system. A randomized comparison of these 2 systems has not been performed. OBJECTIVE: To determine whether the balloon-expandable device is associated with a better success rate than the self-expandable device. DESIGN, SETTING, AND PATIENTS: The CHOICE study was an investigator-initiated trial in high-risk patients with severe aortic stenosis and an anatomy suitable for the transfemoral TAVR procedure. One hundred twenty-one patients were randomly assigned to receive a balloon-expandable valve (Edwards Sapien XT) and 120 were assigned to receive a self-expandable valve (Medtronic CoreValve). Patients were enrolled between March 2012 and December 2013 at 5 centers in Germany. INTERVENTIONS: Transfemoral TAVR with a balloon-expandable or self-expandable device. MAIN OUTCOMES AND MEASURES: The primary end point was device success, which is a composite end point including successful vascular access and deployment of the device and retrieval of the delivery system, correct position of the device, intended performance of the heart valve without moderate or severe regurgitation, and only 1 valve implanted in the proper anatomical location. Secondary end points included cardiovascular mortality, bleeding and vascular complications, postprocedural pacemaker placement, and a combined safety end point at 30 days, including all-cause mortality, major stroke, and other serious complications. RESULTS: Device success occurred in 116 of 121 patients (95.9%) in the balloon-expandable valve group and 93 of 120 patients (77.5%) in the self-expandable valve group (relative risk [RR], 1.24, 95% CI, 1.12-1.37, P < .001). This was attributed to a significantly lower frequency of residual more-than-mild aortic regurgitation (4.1% vs 18.3%; RR, 0.23; 95% CI, 0.09-0.58; P < .001) and the less frequent need for implanting more than 1 valve (0.8% vs 5.8%, P = .03) in the balloon-expandable valve group. Cardiovascular mortality at 30 days was 4.1% in the balloon-expandable valve group and 4.3% in the self-expandable valve group (RR, 0.97; 95% CI, 0.29-3.25; P = .99). Bleeding and vascular complications were not significantly different, and the combined safety end point occurred in 18.2% of those in the balloon-expandable valve group and 23.1% of the self-expandable valve group (RR, 0.79; 95% CI, 0.48-1.30; P = .42). Placement of a new permanent pacemaker was less frequent in the balloon-expandable valve group (17.3% vs 37.6%, P = .001). CONCLUSIONS AND RELEVANCE: Among patients with high-risk aortic stenosis undergoing TAVR, the use of a balloon-expandable valve resulted in a greater rate of device success than use of a self-expandable valve. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01645202.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
EQ-SD: a measure of health status from the EuroQol Group
Rabin, R., & Charro, F. D. (2001) · Annals of Medicine · doi:10.3109/07853890109002087 · Cited by 5,613
Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound
Zoghbi, W. A., Chambers, J. B., Dumesnil, J. G., Foster, E., Gottdiener, J. S., Grayburn, P. A., Khandheria, B. K., Levine, R. A., Marx, G. R., Miller, F. A., et al. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.07.013 · Cited by 1,259
Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,219
Tamburino, C., Capodanno, D., Ramondo, A., Petronio, A. S., Ettori, F., Santoro, G., Klugmann, S., Bedogni, F., Maisano, F., Marzocchi, A., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.946533 · Cited by 1,124
Grube, E., Schuler, G., Buellesfeld, L., Gerckens, U., Linke, A., Wenaweser, P., Sauren, B., Mohr, F.-W., Walther, T., Zickmann, B., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.047 · Cited by 959
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Left retrograde cardioangiography in acquired cardiac disease
Sellers, R. D., Levy, M. J., Amplatz, K., & Lillehei, C. W. (1964) · The American Journal of Cardiology · doi:10.1016/0002-9149(64)90027-x · Cited by 800
Athappan, G., Patvardhan, E., Tuzcu, E. M., Svensson, L. G., Lemos, P. A., Fraccaro, C., Tarantini, G., Sinning, J.-M., Nickenig, G., Capodanno, D., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.047 · Cited by 782
Vahanian, A., Alfieri, O., Al-Attar, N., Antunes, M., Bax, J., Cormier, B., Cribier, A., De Jaegere, P., Fournial, G., Kappetein, A. P., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn183 · Cited by 719
Transcatheter Versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2012) · Survey of Anesthesiology · doi:10.1097/01.sa.0000410147.99581.d4 · Cited by 633
Barbanti, M., Yang, T.-H., Rodès Cabau, J., Tamburino, C., Wood, D. A., Jilaihawi, H., Blanke, P., Makkar, R. R., Latib, A., Colombo, A., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.002947 · Cited by 601
Transcatheter Aortic Valve Implantation: Impact on Clinical and Valve-Related Outcomes
Webb, J. G., Altwegg, L., Boone, R. H., Cheung, A., Ye, J., Lichtenstein, S., Lee, M., Masson, J. B., Thompson, C., Moss, R., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.837807 · Cited by 589
Noninvasive Evaluation of the Aortic Root With Multislice Computed Tomography
Tops, L. F., Wood, D. A., Delgado, V., Schuijf, J. D., Mayo, J. R., Pasupati, S., Lamers, F. P. L., van der Wall, E. E., Schalij, M. J., Webb, J. G., et al. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.12.006 · Cited by 518
Abdel-Wahab, M., Zahn, R., Horack, M., Gerckens, U., Schuler, G., Sievert, H., Eggebrecht, H., Senges, J., Richardt, G., & for the German transcatheter aortic valve interventions registry investigators (2011) · Heart · doi:10.1136/hrt.2010.217158 · Cited by 474
Self-citationParavalvular Leak After Transcatheter Aortic Valve Replacement
Généreux, P., Head, S. J., Hahn, R., Daneault, B., Kodali, S., Williams, M. R., van Mieghem, N. M., Alu, M. C., Serruys, P. W., Kappetein, A. P., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.08.1039 · Cited by 447
Sinning, J.-M., Hammerstingl, C., Vasa-Nicotera, M., Adenauer, V., Lema Cachiguango, S. J., Scheer, A.-C., Hausen, S., Sedaghat, A., Ghanem, A., Müller, C., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.048 · Cited by 411
Willson, A. B., Webb, J. G., LaBounty, T. M., Achenbach, S., Moss, R., Wheeler, M., Thompson, C., Min, J. K., Gurvitch, R., Norgaard, B. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.015 · Cited by 407
Grube, E., Buellesfeld, L., Mueller, R., Sauren, B., Zickmann, B., Nair, D., Beucher, H., Felderhoff, T., Iversen, S., & Gerckens, U. (2008) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.108.819839 · Cited by 352
Vahanian, A., Alfieri, O. R., Al-Attar, N., Antunes, M. J., Bax, J., Cormier, B., Cribier, A., De Jaegere, P., Fournial, G., Kappetein, A. P., et al. (2008) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2008.04.039 · Cited by 305
Standardized Imaging for Aortic Annular Sizing
Kasel, A. M., Cassese, S., Bleiziffer, S., Amaki, M., Hahn, R. T., Kastrati, A., & Sengupta, P. P. (2013) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2012.12.005 · Cited by 240
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Carabello, B. A. (2011) · Current Cardiology Reports · doi:10.1007/s11886-011-0173-6 · Cited by 201
Chieffo, A., Buchanan, G. L., Van Mieghem, N. M., Tchetche, D., Dumonteil, N., Latib, A., van der Boon, R. M. A., Vahdat, O., Marcheix, B., Farah, B., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.050 · Cited by 183
Tzamtzis, S., Viquerat, J., Yap, J., Mullen, M. J., & Burriesci, G. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.04.009 · Cited by 179
Transapical Aortic Valve Implantation
Unbehaun, A., Pasic, M., Dreysse, S., Drews, T., Kukucka, M., Mladenow, A., Ivanitskaja-Kühn, E., Hetzer, R., & Buz, S. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.10.857 · Cited by 165
Determinants and Outcomes of Acute Transcatheter Valve-in-Valve Therapy or Embolization
Makkar, R., Jilaihawi, H., Chakravarty, T., Fontana, G. P., Kapadia, S. R., Babaliaros, V. C., Cheng, W., Thourani, V. H., Bavaria, J. E., Svensson, L. G., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.04.037 · Cited by 156
Willson, A. B., Webb, J. G., Freeman, M., Wood, D. A., Gurvitch, R., Thompson, C., Moss, R., Toggweiler, S., Binder, R., Munt, B. I., et al. (2012) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2012.10.002 · Cited by 98
Sherif, M., Abdel‐Wahab, M., Beurich, H.-W., Stöcker, B., Zachow, D., Geist, V., Tölg, R., & Richardt, G. (2011) · EuroIntervention · doi:10.4244/eijv7i8a12 · Cited by 98
Self-citationy, L. N.-F., Ruel, M., Radhakrishnan, S., Webb, J. G., Hansen, M., Labinaz, M. X., Thompson, C., Fremes, S. E., Dumont, É., DeLarochellière, R., et al. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.11.063 · Cited by 85
Abdel‐Wahab, M., Comberg, T., Büttner, H. J., El‐Mawardy, M., Chatani, K., Gick, M., Geist, V., Richardt, G., & Neumann, F. (2014) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2013.11.011 · Cited by 72
Self-citationTchétché, D., Modine, T., Farah, B., Vahdat, O., Sudre, A., Koussa, M., LeReun, C., Nejjari, M., Choby, M., Rosencher, J., et al. (2012) · EuroIntervention · doi:10.4244/eijv8i5a86 · Cited by 54
Merten, C., Beurich, H.-W., Zachow, D., Mostafa, A. E., Geist, V., Töelg, R., Richardt, G., & Abdel‐Wahab, M. (2013) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.112.000115 · Cited by 53
Self-citationZegdi, R., Lécuyer, L., Achouh, P., Blanchard, D., Lafont, A. M., Latrémouille, C., & Fabiani, J. (2010) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.12.022 · Cited by 43
Unbehaun, A., Pasic, M., Dreysse, S. T., Buz, S., Drews, T., D’Ancona, G., Kukucka, M., Mladenow, A., Ivanitskaja-Kühn, E., & Hetzer, R. (2012) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-0031-1297484 · Cited by 18
Cited by
Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
Adams, D. H., Popma, J. J., Reardon, M. J., Yakubov, S. J., Coselli, J. S., Deeb, G. M., Gleason, T. G., Buchbinder, M., Hermiller, J., Kleiman, N. S., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1400590 · Cited by 2,902
Lindman, B. R., Clavel, M.-A., Mathieu, P., Iung, B., Lancellotti, P., Otto, C. M., & Pibarot, P. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2016.6 · Cited by 982
Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Valve Stenosis
Thyregod, H. G. H., Steinbrüchel, D. A., Ihlemann, N., Nissen, H., Kjeldsen, B. J., Petursson, P., Chang, Y., Franzen, O. W., Engstrøm, T., Clemmensen, P., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.03.014 · Cited by 933
Auffret, V., Puri, R., Urena, M., Chamandi, C., Rodriguez-Gabella, T., Philippon, F., & Rodés-Cabau, J. (2017) · Circulation · doi:10.1161/circulationaha.117.028352 · Cited by 550
Otto, C. M., Kumbhani, D. J., Alexander, K. P., Calhoon, J. H., Desai, M. Y., Kaul, S., Lee, J. C., Ruiz, C. E., & Vassileva, C. M. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.12.006 · Cited by 512
Metadata
- Authors
- Abdel-Wahab, M., Mehilli, J., Frerker, C., Neumann, F.-J., Kurz, T., Tölg, R., Zachow, D., Guerra, E., Massberg, S., Schäfer, U., El-Mawardy, M., & Richardt, G.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2014-04-16
- Volume
- 311
- Issue
- 15
- Pages
- 1503
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2107912271
- Cited by
- 686
- References
- 37
- FWCI
- 58.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.