Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 621

The DOI matches its Crossref record.

Effect of Intravascular Ultrasound–Guided vs Angiography-Guided Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial

Open access
Hong, Sung-Jin, Kim, Byeong-Keuk, Shin, Dong-Ho, Nam, Chung-Mo, Kim, Jung-Sun, Ko, Young-Guk, Choi, Donghoon, Kang, Tae-Soo, Kang, Woong-Chol, Her, Ae-Young, Kim, Yong Hoon, Hur, Seung-Ho, Hong, Bum-Kee, Kwon, Hyuckmoon, Jang, Yangsoo, Hong, Myeong-Ki, for the IVUS-XPL Investigators·2015·JAMA

Abstract

IMPORTANCE: Use of intravascular ultrasound (IVUS) promotes better clinical outcomes for coronary intervention in complex coronary lesions. However, randomized data demonstrating the clinical usefulness of IVUS are limited for lesions treated with drug-eluting stents. OBJECTIVE: To determine whether the long-term clinical outcomes with IVUS-guided drug-eluting stent implantation are superior to those with angiography-guided implantation in patients with long coronary lesions. DESIGN, SETTING, AND PARTICIPANTS: The Impact of Intravascular Ultrasound Guidance on Outcomes of Xience Prime Stents in Long Lesions (IVUS-XPL) randomized, multicenter trial was conducted in 1400 patients with long coronary lesions (implanted stent ≥28 mm in length) between October 2010 and July 2014 at 20 centers in Korea. INTERVENTIONS: Patients were randomly assigned to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation. MAIN OUTCOMES AND MEASURES: Primary outcome measure was the composite of major adverse cardiac events, including cardiac death, target lesion-related myocardial infarction, or ischemia-driven target lesion revascularization at 1 year, analyzed by intention-to-treat. RESULTS: One-year follow-up was complete in 1323 patients (94.5%). Major adverse cardiac events at 1 year occurred in 19 patients (2.9%) undergoing IVUS-guided and in 39 patients (5.8%) undergoing angiography-guided stent implantation (absolute difference, -2.97% [95% CI, -5.14% to -0.79%]) (hazard ratio [HR], 0.48 [95% CI, 0.28 to 0.83], P = .007). The difference was driven by a lower risk of ischemia-driven target lesion revascularization in patients undergoing IVUS-guided (17 [2.5%]) compared with angiography-guided (33 [5.0%]) stent implantation (HR, 0.51 [95% CI, 0.28 to 0.91], P = .02). Cardiac death and target lesion-related myocardial infarction were not significantly different between the 2 groups. For cardiac death, there were 3 patients (0.4%) in the IVUS-guided group and 5 patients (0.7%) in the angiography-guided group (HR, 0.60 [95% CI, 0.14 to 2.52], P = .48). Target lesion-related myocardial infarction occurred in 1 patient (0.1%) in the angiography-guided stent implantation group (P = .32). CONCLUSIONS AND RELEVANCE: Among patients requiring long coronary stent implantation, the use of IVUS-guided everolimus-eluting stent implantation, compared with angiography-guided stent implantation, resulted in a significantly lower rate of the composite of major adverse cardiac events at 1 year. These differences were primarily due to lower risk of target lesion revascularization. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01308281.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2015.15454

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 621

Metadata

Authors
Hong, S.-J., Kim, B.-K., Shin, D.-H., Nam, C.-M., Kim, J.-S., Ko, Y.-G., Choi, D., Kang, T.-S., Kang, W.-C., Her, A.-Y., Kim, Y. H., Hur, S.-H., Hong, B.-K., Kwon, H., Jang, Y., Hong, M.-K., & for the IVUS-XPL Investigators
Venue
JAMA
Published
2015-11-24
Volume
314
Issue
20
Pages
2155
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2174803828
Cited by
621
References
0
FWCI
39.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of Intravascular Ultrasound–Guided vs Angiography-Guided Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial. https://app.cochat.ai/papers/10.1001/jama.2015.15454
The paper
Hong, S.-J., Kim, B.-K., Shin, D.-H., Nam, C.-M., Kim, J.-S., Ko, Y.-G., Choi, D., Kang, T.-S., Kang, W.-C., Her, A.-Y., Kim, Y. H., Hur, S.-H., Hong, B.-K., Kwon, H., Jang, Y., Hong, M.-K., & for the IVUS-XPL Investigators. (2015). Effect of Intravascular Ultrasound–Guided vs Angiography-Guided Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial. JAMA. https://doi.org/10.1001/jama.2015.15454

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.