Abstract
IMPORTANCE: Use of intravascular ultrasound (IVUS) promotes better clinical outcomes for coronary intervention in complex coronary lesions. However, randomized data demonstrating the clinical usefulness of IVUS are limited for lesions treated with drug-eluting stents. OBJECTIVE: To determine whether the long-term clinical outcomes with IVUS-guided drug-eluting stent implantation are superior to those with angiography-guided implantation in patients with long coronary lesions. DESIGN, SETTING, AND PARTICIPANTS: The Impact of Intravascular Ultrasound Guidance on Outcomes of Xience Prime Stents in Long Lesions (IVUS-XPL) randomized, multicenter trial was conducted in 1400 patients with long coronary lesions (implanted stent ≥28 mm in length) between October 2010 and July 2014 at 20 centers in Korea. INTERVENTIONS: Patients were randomly assigned to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation. MAIN OUTCOMES AND MEASURES: Primary outcome measure was the composite of major adverse cardiac events, including cardiac death, target lesion-related myocardial infarction, or ischemia-driven target lesion revascularization at 1 year, analyzed by intention-to-treat. RESULTS: One-year follow-up was complete in 1323 patients (94.5%). Major adverse cardiac events at 1 year occurred in 19 patients (2.9%) undergoing IVUS-guided and in 39 patients (5.8%) undergoing angiography-guided stent implantation (absolute difference, -2.97% [95% CI, -5.14% to -0.79%]) (hazard ratio [HR], 0.48 [95% CI, 0.28 to 0.83], P = .007). The difference was driven by a lower risk of ischemia-driven target lesion revascularization in patients undergoing IVUS-guided (17 [2.5%]) compared with angiography-guided (33 [5.0%]) stent implantation (HR, 0.51 [95% CI, 0.28 to 0.91], P = .02). Cardiac death and target lesion-related myocardial infarction were not significantly different between the 2 groups. For cardiac death, there were 3 patients (0.4%) in the IVUS-guided group and 5 patients (0.7%) in the angiography-guided group (HR, 0.60 [95% CI, 0.14 to 2.52], P = .48). Target lesion-related myocardial infarction occurred in 1 patient (0.1%) in the angiography-guided stent implantation group (P = .32). CONCLUSIONS AND RELEVANCE: Among patients requiring long coronary stent implantation, the use of IVUS-guided everolimus-eluting stent implantation, compared with angiography-guided stent implantation, resulted in a significantly lower rate of the composite of major adverse cardiac events at 1 year. These differences were primarily due to lower risk of target lesion revascularization. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01308281.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
2014 ESC/EACTS Guidelines on myocardial revascularization
Kolh, P., Windecker, S., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu366 · Cited by 4,199
Thygesen, K. A. (2007) · Circulation · Cited by 3,126
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Mintz, G. S., Nissen, S. E., Anderson, W. D., Bailey, S. R., Erbel, R., Fitzgerald, P. J., Pinto, F. J., Rosenfield, K., Siegel, R. J., Tuzcu, E. M., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01175-5 · Cited by 2,185
Daemen, J., Wenaweser, P., Tsuchida, K., Abrecht, L., Vaina, S., Morger, C., Kukreja, N., Jüni, P., Sianos, G., Hellige, G., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60314-6 · Cited by 1,757
Stent Thrombosis in Randomized Clinical Trials of Drug-Eluting Stents
Mauri, L., Hsieh, W.-H., Massaro, J. M., Ho, K. K. L., D'Agostino, R., & Cutlip, D. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067731 · Cited by 1,441
Palmerini, T., Biondi-Zoccai, G., Riva, D. D., Stettler, C., Sangiorgi, D., D'Ascenzo, F., Kimura, T., Briguori, C., Sabatè, M., Kim, H.-S., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60324-9 · Cited by 959
Stone, G. W., Ellis, S. G., Cannon, L., Mann, J. T., Greenberg, J. D., Spriggs, D., O'Shaughnessy, C. D., DeMaio, S., Hall, P., Popma, J. J., et al. (2005) · JAMA · doi:10.1001/jama.294.10.1215 · Cited by 765
Moussa, I. D., Klein, L. W., Shah, B., Mehran, R., Mack, M. J., Brilakis, E. S., Reilly, J. P., Zoghbi, G., Holper, E., & Stone, G. W. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.08.720 · Cited by 650
Cited by
2023 ESC Guidelines for the management of acute coronary syndromes
Byrne, R. A., Rossello, X., Coughlan, J. J., Barbato, E., Berry, C., Chieffo, A., Claeys, M. J., Dan, G.-A., Dweck, M. R., Galbraith, M., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad191 · Cited by 5,333
2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.09.006 · Cited by 1,558
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001038 · Cited by 829
Räber, L., Mintz, G. S., Koskinas, K. C., Johnson, T. W., Holm, N. R., Onuma, Y., Radu, M. D., Joner, M., Yu, B., Jia, H., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy285 · Cited by 770
Intravascular Ultrasound Versus Angiography-Guided Drug-Eluting Stent Implantation
Zhang, J., Gao, X., Kan, J., Ge, Z., Han, L., Lu, S., Tian, N., Lin, S., Lu, Q., Wu, X., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.09.013 · Cited by 665
Ali, Z. A., Maehara, A., Généreux, P., Shlofmitz, R. A., Fabbiocchi, F., Nazif, T. M., Guagliumi, G., Meraj, P. M., Alfonso, F., Samady, H., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31922-5 · Cited by 658
Intravascular Imaging–Guided or Angiography-Guided Complex PCI
Lee, J. M., Choi, K. H., Song, Y. B., Lee, J.-Y., Lee, S.-J., Lee, S. Y., Kim, S. M., Yun, K. H., Cho, J. Y., Kim, C. J., et al. (2023) · New England Journal of Medicine · doi:10.1056/nejmoa2216607 · Cited by 572
Self-citationGao, X.-F., Ge, Z., Kong, X.-Q., Kan, J., Han, L., Lu, S., Tian, N.-L., Lin, S., Lu, Q.-H., Wang, X.-Y., et al. (2021) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2020.10.001 · Cited by 338
2023 ESC Guidelines for the management of acute coronary syndromes
Byrne, R. A., Rossello, X., Coughlan, J. J., Barbato, E., Berry, C., Chieffo, A., Claeys, M. J., Dan, G.-A., Dweck, M. R., Galbraith, M., et al. (2024) · European Heart Journal: Acute Cardiovascular Care · doi:10.1093/ehjacc/zuad107 · Cited by 314
Effect of Intravascular Ultrasound–Guided Drug-Eluting Stent Implantation
Hong, S.-J., Mintz, G. S., Ahn, C.-M., Kim, J.-S., Kim, B.-K., Ko, Y.-G., Kang, T.-S., Kang, W.-C., Kim, Y. H., Hur, S.-H., et al. (2020) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.09.033 · Cited by 294
Self-citationKubo, T., Shinke, T., Okamura, T., Hibi, K., Nakazawa, G., Morino, Y., Shite, J., Fusazaki, T., Otake, H., Kozuma, K., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx351 · Cited by 288
Buccheri, S., Franchina, G., Romano, S., Puglisi, S., Venuti, G., D’Arrigo, P., Francaviglia, B., Scalia, M., Condorelli, A., Barbanti, M., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.08.051 · Cited by 274
IVUS-Guided Versus OCT-Guided Coronary Stent Implantation
Maehara, A., Matsumura, M., Ali, Z. A., Mintz, G. S., & Stone, G. W. (2017) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2017.09.008 · Cited by 256
Intravascular Imaging During Percutaneous Coronary Intervention
Truesdell, A. G., Alasnag, M. A., Kaul, P., Rab, S. T., Riley, R. F., Young, M. N., Batchelor, W. B., Maehara, A., Welt, F. G., & Kirtane, A. J. (2023) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.11.045 · Cited by 222
Elgendy, I. Y., Mahmoud, A. N., Elgendy, A. Y., & Bavry, A. A. (2016) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.116.003700 · Cited by 199
Darmoch, F., Alraies, M. C., Al‐Khadra, Y., Moussa Pacha, H., Pinto, D. S., & Osborn, E. A. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.119.013678 · Cited by 184
Choi, K. H., Song, Y. B., Lee, J. M., Lee, S. Y., Park, T. K., Yang, J. H., Choi, J.-H., Choi, S.-H., Gwon, H.-C., & Hahn, J.-Y. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.01.227 · Cited by 179
Kang, D.-Y., Ahn, J.-M., Yun, S.-C., Hur, S.-H., Cho, Y.-K., Lee, C. H., Hong, S. J., Lim, S., Kim, S.-W., Won, H., et al. (2023) · Circulation · doi:10.1161/circulationaha.123.066429 · Cited by 170
Self-citation
Metadata
- Authors
- Hong, S.-J., Kim, B.-K., Shin, D.-H., Nam, C.-M., Kim, J.-S., Ko, Y.-G., Choi, D., Kang, T.-S., Kang, W.-C., Her, A.-Y., Kim, Y. H., Hur, S.-H., Hong, B.-K., Kwon, H., Jang, Y., Hong, M.-K., & for the IVUS-XPL Investigators
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2015-11-24
- Volume
- 314
- Issue
- 20
- Pages
- 2155
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2174803828
- Cited by
- 621
- References
- 21
- FWCI
- 39.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.