CoChat

Antiplatelet Therapy Duration Following Bare Metal or Drug-Eluting Coronary Stents: The Dual Antiplatelet Therapy Randomized Clinical Trial

Open access
Kereiakes, Dean J., Yeh, Robert W., Massaro, Joseph M., Driscoll-Shempp, Priscilla, Cutlip, Donald E., Steg, P. Gabriel, Gershlick, Anthony H., Darius, Harald, Meredith, Ian T., Ormiston, John, Tanguay, Jean Francois, Windecker, Stephan, Garratt, Kirk N., Kandzari, David E., Lee, David P., Simon, Daniel I., Iancu, Adrian Corneliu, Trebacz, Jaroslaw, Mauri, Laura, for the Dual Antiplatelet Therapy (DAPT) Study Investigators · 2015 · JAMA
Cited by 94

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

IMPORTANCE: Despite antirestenotic efficacy of coronary drug-eluting stents (DES) compared with bare metal stents (BMS), the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Although dual antiplatelet therapy (DAPT) beyond 1 year provides ischemic event protection after DES, ischemic event risk is perceived to be less after BMS, and the appropriate duration of DAPT after BMS is unknown. OBJECTIVE: To compare (1) rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE; composite of death, myocardial infarction, or stroke) after 30 vs 12 months of thienopyridine in patients treated with BMS taking aspirin and (2) treatment duration effect within the combined cohorts of randomized patients treated with DES or BMS as prespecified secondary analyses. DESIGN, SETTING, AND PARTICIPANTS: International, multicenter, randomized, double-blinded, placebo-controlled trial comparing extended (30-months) thienopyridine vs placebo in patients taking aspirin who completed 12 months of DAPT without bleeding or ischemic events after receiving stents. The study was initiated in August 2009 with the last follow-up visit in May 2014. INTERVENTIONS: Continued thienopyridine or placebo at months 12 through 30 after stent placement, in 11,648 randomized patients treated with aspirin, of whom 1687 received BMS and 9961 DES. MAIN OUTCOMES AND MEASURES: Stent thrombosis, MACCE, and moderate or severe bleeding. RESULTS: Among 1687 patients treated with BMS who were randomized to continued thienopyridine vs placebo, rates of stent thrombosis were 0.5% vs 1.11% (n = 4 vs 9; hazard ratio [HR], 0.49; 95% CI, 0.15-1.64; P = .24), rates of MACCE were 4.04% vs 4.69% (n = 33 vs 38; HR, 0.92; 95% CI, 0.57-1.47; P = .72), and rates of moderate/severe bleeding were 2.03% vs 0.90% (n = 16 vs 7; P = .07), respectively. Among all 11,648 randomized patients (both BMS and DES), stent thrombosis rates were 0.41% vs 1.32% (n = 23 vs 74; HR, 0.31; 95% CI, 0.19-0.50; P < .001), rates of MACCE were 4.29% vs 5.74% (n = 244 vs 323; HR, 0.73; 95% CI, 0.62-0.87; P < .001), and rates of moderate/severe bleeding were 2.45% vs 1.47% (n = 135 vs 80; P < .001). CONCLUSIONS AND RELEVANCE: Among patients undergoing coronary stent placement with BMS and who tolerated 12 months of thienopyridine, continuing thienopyridine for an additional 18 months compared with placebo did not result in statistically significant differences in rates of stent thrombosis, MACCE, or moderate or severe bleeding. However, the BMS subset may have been underpowered to identify such differences, and further trials are suggested. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00977938.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2015.1671

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 94

Metadata

Authors
Kereiakes, D. J., Yeh, R. W., Massaro, J. M., Driscoll-Shempp, P., Cutlip, D. E., Steg, P. G., Gershlick, A. H., Darius, H., Meredith, I. T., Ormiston, J., Tanguay, J. F., Windecker, S., Garratt, K. N., Kandzari, D. E., Lee, D. P., Simon, D. I., Iancu, A. C., Trebacz, J., Mauri, L., & for the Dual Antiplatelet Therapy (DAPT) Study Investigators
Venue
JAMA
Published
2015-03-17
Volume
313
Issue
11
Pages
1113
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2140676515
Cited by
94
References
2
FWCI
13.16
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.