The DOI matches its Crossref record.
Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution: A Randomized Clinical Trial
Open accessAbstract
IMPORTANCE: Endoscopic placement of multiple plastic stents in parallel is the first-line treatment for most benign biliary strictures; it is possible that fully covered, self-expandable metallic stents (cSEMS) may require fewer endoscopic retrograde cholangiopancreatography procedures (ERCPs) to achieve resolution. OBJECTIVE: To assess whether use of cSEMS is noninferior to plastic stents with respect to stricture resolution. DESIGN, SETTING, AND PARTICIPANTS: Multicenter (8 endoscopic referral centers), open-label, parallel, randomized clinical trial involving patients with treatment-naive, benign biliary strictures (N = 112) due to orthotopic liver transplant (n = 73), chronic pancreatitis (n = 35), or postoperative injury (n = 4), who were enrolled between April 2011 and September 2014 (with follow-up ending October 2015). Patients with a bile duct diameter less than 6 mm and those with an intact gallbladder in whom the cystic duct would be overlapped by a cSEMS were excluded. INTERVENTIONS: Patients (N = 112) were randomized to receive multiple plastic stents or a single cSEMS, stratified by stricture etiology and with endoscopic reassessment for resolution every 3 months (plastic stents) or every 6 months (cSEMS). Patients were followed up for 12 months after stricture resolution to assess for recurrence. MAIN OUTCOMES AND MEASURES: Primary outcome was stricture resolution after no more than 12 months of endoscopic therapy. The sample size was estimated based on the noninferiority of cSEMS to plastic stents, with a noninferiority margin of -15%. RESULTS: There were 55 patients in the plastic stent group (mean [SD] age, 57 [11] years; 17 women [31%]) and 57 patients in the cSEMS group (mean [SD] age, 55 [10] years; 19 women [33%]). Compared with plastic stents (41/48, 85.4%), the cSEMS resolution rate was 50 of 54 patients (92.6%), with a rate difference of 7.2% (1-sided 95% CI, -3.0% to ∞; P < .001). Given the prespecified noninferiority margin of -15%, the null hypothesis that cSEMS is less effective than plastic stents was rejected. The mean number of ERCPs to achieve resolution was lower for cSEMS (2.14) vs plastic (3.24; mean difference, 1.10; 95% CI, 0.74 to 1.46; P < .001). CONCLUSIONS AND RELEVANCE: Among patients with benign biliary strictures and a bile duct diameter 6 mm or more in whom the covered metallic stent would not overlap the cystic duct, cSEMS were not inferior to multiple plastic stents after 12 months in achieving stricture resolution. Metallic stents should be considered an appropriate option in patients such as these. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01221311.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dumonceau, J.-M., Tringali, A., Papanikolaou, I., Blero, D., Mangiavillano, B., Schmidt, A., Vanbiervliet, G., Costamagna, G., Devière, J., García-Cano, J., et al. (2018) · Endoscopy · doi:10.1055/a-0659-9864 · Cited by 789
Kleeff, J., Whitcomb, D. C., Shimosegawa, T., Esposito, I., Lerch, M. M., Gress, T., Mayerle, J., Drewes, A. M., Rebours, V., Akisik, F., et al. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.60 · Cited by 461
Management of chronic pancreatitis
Hines, O. J., & Pandol, S. J. (2024) · BMJ · doi:10.1136/bmj-2023-070920 · Cited by 58
Metadata
- Authors
- Coté, G. A., Slivka, A., Tarnasky, P., Mullady, D. K., Elmunzer, B. J., Elta, G., Fogel, E., Lehman, G., McHenry, L., Romagnuolo, J., Menon, S., Siddiqui, U. D., Watkins, J., Lynch, S., Denski, C., Xu, H., & Sherman, S.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2016-03-22
- Volume
- 315
- Issue
- 12
- Pages
- 1250
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2311493960
- Cited by
- 244
- References
- 0
- FWCI
- 27.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution: A Randomized Clinical Trial. https://app.cochat.ai/papers/10.1001/jama.2016.2619
- The paper
- Coté, G. A., Slivka, A., Tarnasky, P., Mullady, D. K., Elmunzer, B. J., Elta, G., Fogel, E., Lehman, G., McHenry, L., Romagnuolo, J., Menon, S., Siddiqui, U. D., Watkins, J., Lynch, S., Denski, C., Xu, H., & Sherman, S. (2016). Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution: A Randomized Clinical Trial. JAMA. https://doi.org/10.1001/jama.2016.2619
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.