Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 456

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Comparison of Abbreviated Breast MRI vs Digital Breast Tomosynthesis for Breast Cancer Detection Among Women With Dense Breasts Undergoing Screening

Open access
Comstock, Christopher E., Gatsonis, Constantine, Newstead, Gillian M., Snyder, Bradley S., Gareen, Ilana F., Bergin, Jennifer T., Rahbar, Habib, Sung, Janice S., Jacobs, Christina, Harvey, Jennifer A., Nicholson, Mary H., Ward, Robert C., Holt, Jacqueline, Prather, Andrew, Miller, Kathy D., Schnall, Mitchell D., Kuhl, Christiane K. · 2020 · JAMA

Abstract

Importance: Improved screening methods for women with dense breasts are needed because of their increased risk of breast cancer and of failed early diagnosis by screening mammography. Objective: To compare the screening performance of abbreviated breast magnetic resonance imaging (MRI) and digital breast tomosynthesis (DBT) in women with dense breasts. Design, Setting, and Participants: Cross-sectional study with longitudinal follow-up at 48 academic, community hospital, and private practice sites in the United States and Germany, conducted between December 2016 and November 2017 among average-risk women aged 40 to 75 years with heterogeneously dense or extremely dense breasts undergoing routine screening. Follow-up ascertainment of cancer diagnoses was complete through September 12, 2019. Exposures: All women underwent screening by both DBT and abbreviated breast MRI, performed in randomized order and read independently to avoid interpretation bias. Main Outcomes and Measures: The primary end point was the invasive cancer detection rate. Secondary outcomes included sensitivity, specificity, additional imaging recommendation rate, and positive predictive value (PPV) of biopsy, using invasive cancer and ductal carcinoma in situ (DCIS) to define a positive reference standard. All outcomes are reported at the participant level. Pathology of core or surgical biopsy was the reference standard for cancer detection rate and PPV; interval cancers reported until the next annual screen were included in the reference standard for sensitivity and specificity. Results: Among 1516 enrolled women, 1444 (median age, 54 [range, 40-75] years) completed both examinations and were included in the analysis. The reference standard was positive for invasive cancer with or without DCIS in 17 women and for DCIS alone in another 6. No interval cancers were observed during follow-up. Abbreviated breast MRI detected all 17 women with invasive cancer and 5 of 6 women with DCIS. Digital breast tomosynthesis detected 7 of 17 women with invasive cancer and 2 of 6 women with DCIS. The invasive cancer detection rate was 11.8 (95% CI, 7.4-18.8) per 1000 women for abbreviated breast MRI vs 4.8 (95% CI, 2.4-10.0) per 1000 women for DBT, a difference of 7 (95% CI, 2.2-11.6) per 1000 women (exact McNemar P = .002). For detection of invasive cancer and DCIS, sensitivity was 95.7% (95% CI, 79.0%-99.2%) with abbreviated breast MRI vs 39.1% (95% CI, 22.2%-59.2%) with DBT (P = .001) and specificity was 86.7% (95% CI, 84.8%-88.4%) vs 97.4% (95% CI, 96.5%-98.1%), respectively (P < .001). The additional imaging recommendation rate was 7.5% (95% CI, 6.2%-9.0%) with abbreviated breast MRI vs 10.1% (95% CI, 8.7%-11.8%) with DBT (P = .02) and the PPV was 19.6% (95% CI, 13.2%-28.2%) vs 31.0% (95% CI, 17.0%-49.7%), respectively (P = .15). Conclusions and Relevance: Among women with dense breasts undergoing screening, abbreviated breast MRI, compared with DBT, was associated with a significantly higher rate of invasive breast cancer detection. Further research is needed to better understand the relationship between screening methods and clinical outcome. Trial Registration: ClinicalTrials.gov Identifier: NCT02933489.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2020.0572

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 456

Metadata

Authors
Comstock, C. E., Gatsonis, C., Newstead, G. M., Snyder, B. S., Gareen, I. F., Bergin, J. T., Rahbar, H., Sung, J. S., Jacobs, C., Harvey, J. A., Nicholson, M. H., Ward, R. C., Holt, J., Prather, A., Miller, K. D., Schnall, M. D., & Kuhl, C. K.
Venue
JAMA
Published
2020-02-25
Volume
323
Issue
8
Pages
746
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W3006788346
Cited by
456
References
30
FWCI
35.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Abbreviated Breast MRI vs Digital Breast Tomosynthesis for Breast Cancer Detection Among Women With Dense Breasts Undergoing Screening. https://app.cochat.ai/papers/10.1001/jama.2020.0572
The paper
Comstock, C. E., Gatsonis, C., Newstead, G. M., Snyder, B. S., Gareen, I. F., Bergin, J. T., Rahbar, H., Sung, J. S., Jacobs, C., Harvey, J. A., Nicholson, M. H., Ward, R. C., Holt, J., Prather, A., Miller, K. D., Schnall, M. D., & Kuhl, C. K. (2020). Comparison of Abbreviated Breast MRI vs Digital Breast Tomosynthesis for Breast Cancer Detection Among Women With Dense Breasts Undergoing Screening. JAMA. https://doi.org/10.1001/jama.2020.0572

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.