Screening for Obstructive Sleep Apnea in Adults: Updated Evidence Report and Systematic Review for the US Preventive Services Task Force
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Importance: Obstructive sleep apnea (OSA) is associated with adverse health outcomes. Objective: To review the evidence on screening for OSA in asymptomatic adults or those with unrecognized OSA symptoms to inform the US Preventive Services Task Force. Data Sources: PubMed/MEDLINE, Cochrane Library, Embase, and trial registries through August 23, 2021; surveillance through September 23, 2022. Study Selection: English-language studies of screening test accuracy, randomized clinical trials (RCTs) of screening or treatment of OSA reporting health outcomes or harms, and systematic reviews of treatment reporting changes in blood pressure and apnea-hypopnea index (AHI) scores. Data Extraction and Synthesis: Dual review of abstracts, full-text articles, and study quality. Meta-analysis of intervention trials. Main Outcomes and Measures: Test accuracy, excessive daytime sleepiness, sleep-related and general health–related quality of life (QOL), and harms. Results: Eighty-six studies were included (N = 11 051). No study directly compared screening with no screening. Screening accuracy of the Multivariable Apnea Prediction score followed by unattended home sleep testing for detecting severe OSA syndrome (AHI ≥30 and Epworth Sleepiness Scale [ESS] score >10) measured as the area under the curve in 2 studies (n = 702) was 0.80 (95% CI, 0.78 to 0.82) and 0.83 (95% CI, 0.77 to 0.90). Five studies assessing the accuracy of other screening tools were heterogeneous and results were inconsistent. Compared with inactive control, positive airway pressure was associated with a significant improvement in ESS score from baseline (pooled mean difference, −2.33 [95% CI, −2.75 to −1.90]; 47 trials; n = 7024), sleep-related QOL (standardized mean difference, 0.30 [95% CI, 0.19 to 0.42]; 17 trials; n = 3083), and general health–related QOL measured by the 36-Item Short Form Health Survey (SF-36) mental health component summary score change (pooled mean difference, 2.20 [95% CI, 0.95 to 3.44]; 15 trials; n = 2345) and SF-36 physical health component summary score change (pooled mean difference, 1.53 [95% CI, 0.29 to 2.77]; 13 trials; n = 2031). Use of mandibular advancement devices was also associated with a significantly larger ESS score change compared with controls (pooled mean difference, −1.67 [95% CI, 2.09 to −1.25]; 10 trials; n = 1540). Reporting of other health outcomes was sparse; no included trial found significant benefit associated with treatment on mortality, cardiovascular events, or motor vehicle crashes. In 3 systematic reviews, positive airway pressure was significantly associated with reduced blood pressure; however, the difference was relatively small (2-3 mm Hg). Conclusions and Relevance: The accuracy and clinical utility of OSA screening tools that could be used in primary care settings were uncertain. Positive airway pressure and mandibular advancement devices reduced ESS score. Trials of positive airway pressure found modest improvement in sleep-related and general health–related QOL but have not established whether treatment reduces mortality or improves most other health outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Increased Prevalence of Sleep-Disordered Breathing in Adults
Peppard, P. E., Young, T., Barnet, J. H., Palta, M., Hagen, E. W., & Hla, K. M. (2013) · American Journal of Epidemiology · doi:10.1093/aje/kws342 · Cited by 4,618
Development of AMSTAR: A measurement tool to assess the methodological quality of systematic reviews
Shea, B. J., Grimshaw, J. M., Wells, G. A., Boers, M., Andersson, N., Hamel, C., Porter, A. C., Tugwell, P., Moher, D., & Bouter, L. M. (2007) · BMC Medical Research Methodology · doi:10.1186/1471-2288-7-10 · Cited by 4,374
Benjafield, A. V., Ayas, N. T., Eastwood, P. R., Heinzer, R., Ip, M. S. M., Morrell, M. J., Nunez, C. M., Patel, S. R., Penzel, T., Pépin, J.-L., et al. (2019) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(19)30198-5 · Cited by 4,326
Using the Berlin Questionnaire To Identify Patients at Risk for the Sleep Apnea Syndrome
Netzer, N. C., Stoohs, R. A., Netzer, C. M., Clark, K., & Strohl, K. P. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-7-199910050-00002 · Cited by 2,973
STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816d83e4 · Cited by 2,355
Prevalence of Sleep-disordered Breathing in Women
BIXLER, E. O., VGONTZAS, A. N., LIN, H.-M., TEN HAVE, T., REIN, J., VELA-BUENO, A., & KALES, A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.9911064 · Cited by 1,598 · cited 2×
“89,120,121,123-132 Most RCTs (6) lasted 4 to 8 weeks, 1 lasted a single week,123 1 lasted 10 weeks,89 1 lasted 12 weeks,124 and 1 lasted 24 weeks.”
BackgroundKaneko, Y., Floras, J. S., Usui, K., Plante, J., Tkacova, R., Kubo, T., Ando, S.-I., & Bradley, T. D. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022479 · Cited by 1,051
Jenkinson, C., Davies, R. J., Mullins, R., & Stradling, J. R. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10532-9 · Cited by 826
Barbé, F., Durán-Cantolla, J., Sánchez-de-la-Torre, M., Martínez-Alonso, M., Carmona, C., Barceló, A., Chiner, E., Masa, J. F., Gonzalez, M., Marín, J. M., et al. (2012) · JAMA · doi:10.1001/jama.2012.4366 · Cited by 792
Cited by
Bushnell, C., Kernan, W. N., Sharrief, A. Z., Chaturvedi, S., Cole, J. W., Cornwell, W. K., Cosby-Gaither, C., Doyle, S., Goldstein, L. B., Lennon, O., et al. (2024) · Stroke · doi:10.1161/str.0000000000000475 · Cited by 360
US Preventive Services Task Force, Mangione, C. M., Barry, M. J., Nicholson, W. K., Cabana, M., Chelmow, D., Rucker Coker, T., Davidson, K. W., Davis, E. M., Donahue, K. E., et al. (2022) · JAMA · doi:10.1001/jama.2022.20304 · Cited by 103
Ndumele, C. E., Rodriguez, F., Dixon, D. L., Khan, S. S., Mukherjee, D., Bajaj, M., Bangalore, S., Bozkurt, B., Breathett, K., Clarke, S. L., et al. (2026) · JACC · doi:10.1016/j.jacc.2026.03.056 · Cited by 90
Holt, A., Bjerre, J., Zareini, B., Koch, H., Tønnesen, P., Gislason, G. H., Nielsen, O. W., Schou, M., & Lamberts, M. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.118.008684 · Cited by 54
Metadata
- Authors
- Feltner, C., Wallace, I. F., Aymes, S., Cook Middleton, J., Hicks, K. L., Schwimmer, M., Baker, C., Balio, C. P., Moore, D., Voisin, C. E., & Jonas, D. E.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2022-11-15
- Volume
- 328
- Issue
- 19
- Pages
- 1951
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W3214188057
- Cited by
- 80
- References
- 48
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Screening for Obstructive Sleep Apnea in Adults: Updated Evidence Report and Systematic Review for the US Preventive Services Task Force. https://app.cochat.ai/papers/10.1001/jama.2022.18357
- The paper
- Feltner, C., Wallace, I. F., Aymes, S., Cook Middleton, J., Hicks, K. L., Schwimmer, M., Baker, C., Balio, C. P., Moore, D., Voisin, C. E., & Jonas, D. E. (2022). Screening for Obstructive Sleep Apnea in Adults: Updated Evidence Report and Systematic Review for the US Preventive Services Task Force. JAMA. https://doi.org/10.1001/jama.2022.18357
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.