Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea

Abstract

Background: Obstructive sleep apnea (OSA) is a major risk factor for perioperative adverse events. However, no screening tool for OSA has been validated in surgical patients. This study was conducted to develop and validate a concise and easy-to-use questionnaire for OSA screening in surgical patients. Methods: After hospital ethics approval, preoperative patients aged 18 yr or older and without previously diagnosed OSA were recruited. After a factor analysis, reliability check, and pilot study; four yes/no questions were used to develop this screening tool. The four questions were respectively related to snoring, tiredness during daytime, observed apnea, and high blood pressure (STOP). For validation, the score from the STOP questionnaire was evaluated versus the apnea-hypopnea index from monitored polysomnography. Results: The STOP questionnaire was given to 2,467 patients, 27.5% classified as being at high risk of OSA. Two hundred eleven patients underwent polysomnography, 34 for the pilot test and 177 for validation. In the validation group, the apnea-hypopnea index was 20 +/- 6. The sensitivities of the STOP questionnaire with apnea-hypopnea index greater than 5, greater than 15, and greater than 30 as cutoffs were 65.6, 74.3, and 79.5%, respectively. When incorporating body mass index, age, neck circumference, and gender into the STOP questionnaire, sensitivities were increased to 83.6, 92.9, and 100% with the same apnea-hypopnea index cutoffs. Conclusions: The STOP questionnaire is a concise and easy-to-use screening tool for OSA. It has been developed and validated in surgical patients at preoperative clinics. Combined with body mass index, age, neck size, and gender, it had a high sensitivity, especially for patients with moderate to severe OSA.

Overview

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e31816d83e4

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

1 more claim about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 43 references

Cited by

See all 2,355

Metadata

Authors
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M.
Affiliations
  • University Health Network (CA)
  • Research Fellow.
  • Research Data Analyst.
  • Research Coordinator, Department of Anesthesia.
Venue
Anesthesiology
Published
2008-05-01
Volume
108
Issue
5
Pages
812-821
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2125397756
Cited by
2,355
References
43
Citations by year
2026: 162 · 2025: 166 · 2024: 151 · 2023: 170 · 2022: 173 · 2021: 191 · 2020: 153 · 2019: 144 · 2018: 152 · 2017: 138 · 2016: 149 · 2015: 135 · 2014: 125 · 2013: 105 · 2012: 94
FWCI
32.59
Type
journal article
Language
en
Open access
closed
Locations
  • Anesthesiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
Keywords
obstructive sleep apnea, STOP questionnaire, OSA screening, surgical patients, preoperative screening, apnea-hypopnea index, polysomnography, snoring, daytime fatigue, hypertension, body mass index, neck circumference, screening tool validation
MeSH terms
Female, Humans, Male, Mass Screening, Surveys and Questionnaires, Body Mass Index, Polysomnography, Sleep Apnea, Obstructive, Body Size

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1097/aln.0b013e31816d83e4
The paper
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008). STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea. Anesthesiology. https://doi.org/10.1097/aln.0b013e31816d83e4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.