Evaluation of Dressing Regimens for Prevention of Infection With Peripheral Intravenous Catheters: Gauze, a Transparent Polyurethane Dressing, and an lodophor-Transparent Dressing
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Four dressing regimens for peripheral venous catheters were studied in a prospective randomized clinical trial with 2088 Teflon catheters: (1) sterile gauze, replaced every other day, and three dressings left on for the lifetime of the catheter; (2) gauze; (3) a transparent polyurethane dressing; and (4) an iodophor-transparent dressing. The four dressings provided comparable coverage, except moisture accumulated more frequently under the transparent dressings 26% to 28% vs 20% to 21% Cutaneous colonization under the dressing was low level and comparable with all four dressings (range, 100.58 to 100.70 colony-forming units). The rate of local catheter-related infection ≥15 colony-forming units) was also low and did not differ significantly (range, 4.6% to 5.9%); no catheter caused bacteremia. Stepwise logistic multivariate analysis showed cutaneous colonization of the insertion site (relative risk [RR] of infection, 3.86), contamination of the catheter hub (RR, 3.78), moisture under the dressing (RR, 2.48), and prolonged catheterization (RR, 1.75) to be significant risk factors for catheter-related infection. These data indicate that it is not cost-effective to redress peripheral venous catheters at periodic intervals; for most patients, either sterile gauze or a transparent dressing can be used and left on until the catheter is removed. (JAMA1987;258:2396-2403)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rank transformations as a bridge between parametric and nonparametric statistics
Conover, W. J., & Iman, R. L. (1981) · The American Statistician · doi:10.1080/00031305.1981.10479327 · Cited by 3,922
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Nasal carriage of Staphylococcus aureus: epidemiology, underlying mechanisms, and associated risks
Kluytmans, J., van Belkum, A., & Verbrugh, H. (1997) · Clinical Microbiology Reviews · doi:10.1128/cmr.10.3.505 · Cited by 2,595
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
Self-citationGuidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control and Hospital Epidemiology · doi:10.1086/502007 · Cited by 847
Self-citationGuidelines for the Prevention of Intravascular Catheter-Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Pediatrics · doi:10.1542/peds.110.5.e51 · Cited by 738
Self-citationGuideline for Prevention of Intravascular-Device-Related Infections
Pearson, M. L., & The Hospital Infection Control Practices Advisory Committee (1996) · Infection Control and Hospital Epidemiology · doi:10.2307/30141155 · Cited by 531
Maki, D. G., & Ringer, M. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-10-845 · Cited by 497
Self-citationInfections Associated with Medical Devices: Pathogenesis, Management and Prophylaxis
von Eiff, C., Jansen, B., Kohnen, W., & Becker, K. (2005) · Drugs · doi:10.2165/00003495-200565020-00003 · Cited by 459
Mermel, L. A., McCormick, R. D., Springman, S. R., & Maki, D. G. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90369-9 · Cited by 441
Self-citationGuidelines for the Prevention of Intravascular Catheter–Related Infections
O'Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Clinical Infectious Diseases · doi:10.1086/344188 · Cited by 440
Self-citationRickard, C. M., Webster, J., Wallis, M. C., Marsh, N., McGrail, M. R., French, V., Foster, L., Gallagher, P., Gowardman, J. R., Zhang, L., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61082-4 · Cited by 428
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · American Journal of Infection Control · doi:10.1067/mic.2002.129427 · Cited by 415
Self-citationMaki, D. G., Cobb, L., Garman, J. K., Shapiro, J. M., Ringer, M., & Helgerson, R. B. (1988) · The American Journal of Medicine · doi:10.1016/0002-9343(88)90579-7 · Cited by 412
Self-citationCentral venous catheter use: Part 1: Mechanical complications
Polderman, K. H., & Girbes, A. R. (2002) · Intensive Care Medicine · doi:10.1007/s00134-001-1154-9 · Cited by 377
Richet, H., Hubert, B., Nitemberg, G., Andremont, A., Buu-Hoi, A., Ourbak, P., Galicier, C., Veron, M., Boisivon, A., & Bouvier, A. M. (1990) · Journal of Clinical Microbiology · doi:10.1128/jcm.28.11.2520-2525.1990 · Cited by 326
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O'Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700080577 · Cited by 319
Self-citationPeripheral venous catheters: an under-evaluated problem
Zingg, W., & Pittet, D. (2009) · International Journal of Antimicrobial Agents · doi:10.1016/s0924-8579(09)70565-5 · Cited by 310
The epidemiology of peripheral vein infusion thrombophlebitis: a critical review
Tagalakis, V., Kahn, S. R., Libman, M., & Blostein, M. (2002) · The American Journal of Medicine · doi:10.1016/s0002-9343(02)01163-4 · Cited by 274
Crnich, C. J., & Maki, D. G. (2002) · Clinical Infectious Diseases · doi:10.1086/339863 · Cited by 264
Self-citationShort-term Peripheral Venous Catheter–Related Bloodstream Infections: A Systematic Review
Mermel, L. A. (2017) · Clinical Infectious Diseases · doi:10.1093/cid/cix562 · Cited by 253
Flowers, R. H. (1989) · JAMA · doi:10.1001/jama.1989.03420060094039 · Cited by 243
Guideline for Prevention of Intravascular-Device–Related Infections
Pearson, M. L., & Hospital Infection Control Practices Advisory Committee (1996) · Infection Control & Hospital Epidemiology · doi:10.1086/647338 · Cited by 201
Central Venous Catheter Infections
Decker, M. D., & Edwards, K. M. (1988) · Pediatric Clinics of North America · doi:10.1016/s0031-3955(16)36473-2 · Cited by 188
Metadata
- Authors
- Maki, D. G.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 1987-11-06
- Volume
- 258
- Issue
- 17
- Pages
- 2396
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W4294141050
- Cited by
- 192
- References
- 1
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.