The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
The Promise of Novel Technology for the Prevention of Intravascular Device–Related Bloodstream Infection. I. Pathogenesis and Short‐Term Devices
Open accessAbstract
Intravascular devices (IVDs) are widely used for vascular access but are associated with substantial risk of development of IVD-related bloodstream infection (BSI). The development of novel technologies, which are based on an understanding of pathogenesis, promises a quantum reduction in IVD-related infections in an era of growing nursing shortages. Infections of short-term IVDs (that is, those in place <10 days), including peripheral venous catheters, noncuffed and nontunneled central venous catheters (CVCs), and arterial catheters, derive mainly from microorganisms colonizing the skin around the insertion site, which most often gain access extraluminally. More-effective cutaneous antiseptics, such as chlorhexidine, a chlorhexidine-impregnated sponge dressing, CVCs with an anti-infective coating, anti-infective CVC hubs, and novel needleless connectors, have all been shown to reduce the risk of IVD-related BSI in prospective randomized trials. The challenge for the future will be to identify new preventative technologies and to begin to adapt more widely those technologies already shown to be efficacious and cost-effective.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Improving the Quality of Reporting of Randomized Controlled Trials: The CONSORT Statement
Begg, C. (1996) · JAMA · doi:10.1001/jama.1996.03540080059030 · Cited by 3,127
Intermittent Administration of Inhaled Tobramycin in Patients with Cystic Fibrosis
Ramsey, B. W., Pepe, M. S., Quan, J. M., Otto, K. L., Montgomery, A. B., Williams-Warren, J., Vasiljev-K, M., Borowitz, D., Bowman, C. M., Marshall, B. C., et al. (1999) · New England Journal of Medicine · doi:10.1056/nejm199901073400104 · Cited by 1,300
Pittet, D. (1994) · JAMA · doi:10.1001/jama.1994.03510440058033 · Cited by 926
Prevention of Intravascular Catheter–Related Infections
Mermel, L. A. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-132-5-200003070-00009 · Cited by 919
Secular trends in nosocomial primary bloodstream infections in the United States, 1980–1989.
Banerjee, S. N., Emori, T. G., Culver, D. H., Gaynes, R. P., Jarvis, W. R., Horan, T., Edwards, J. R., Tolson, J., Henderson, T., Martone, W. J., et al. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90349-3 · Cited by 880
Prevention of Intravascular Catheter-Related Infections
(2021) · Indian Journal of Continuing Nursing Education · doi:10.4103/2230-7354.320831 · Cited by 855
Maki, D. G., Alvarado, C. J., & Ringer, M. (1991) · The Lancet · doi:10.1016/0140-6736(91)90479-9 · Cited by 845
Self-citationA Comparison of Two Antimicrobial-Impregnated Central Venous Catheters
Darouiche, R. O., Raad, I. I., Heard, S. O., Thornby, J. I., Wenker, O. C., Gabrielli, A., Berg, J., Khardori, N., Hanna, H., Hachem, R., et al. (1999) · New England Journal of Medicine · doi:10.1056/nejm199901073400101 · Cited by 804
Maki, D. G., Stolz, S. M., Wheeler, S., & Mermel, L. A. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-4-199708150-00001 · Cited by 753
Self-citation
Cited by
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
Self-citationIntravascular catheter-related infections: advances in diagnosis, prevention, and management
Raad, I., Hanna, H., & Maki, D. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70235-9 · Cited by 525
Self-citationAccepted but Unacceptable: Peripheral IV Catheter Failure
Helm, R. E., Klausner, J. D., Klemperer, J. D., Flint, L. M., & Huang, E. (2015) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000100 · Cited by 445
Parienti, J.-J., Thirion, M., Mégarbane, B., Souweine, B., Ouchikhe, A., Polito, A., Forel, J.-M., Marqué, S., Misset, B., Airapetian, N., et al. (2008) · JAMA · doi:10.1001/jama.299.20.2413 · Cited by 419
Andes, D., Nett, J., Oschel, P., Albrecht, R., Marchillo, K., & Pitula, A. (2004) · Infection and Immunity · doi:10.1128/iai.72.10.6023-6031.2004 · Cited by 389
Metadata
- Authors
- Crnich, C. J., & Maki, D. G.
- Venue
- Clinical Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-05
- Volume
- 34
- Issue
- 9
- Pages
- 1232-1242
- ISSN
- 1058-4838 (ISSN-L)
- 1537-6591
- OpenAlex
- W2022056467
- Cited by
- 264
- References
- 74
- FWCI
- 24.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Promise of Novel Technology for the Prevention of Intravascular Device–Related Bloodstream Infection. I. Pathogenesis and Short‐Term Devices. https://app.cochat.ai/papers/10.1086/339863
- The paper
- Crnich, C. J., & Maki, D. G. (2002). The Promise of Novel Technology for the Prevention of Intravascular Device–Related Bloodstream Infection. I. Pathogenesis and Short‐Term Devices. Clinical Infectious Diseases. https://doi.org/10.1086/339863
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.