Implementation of clinical guidelines using a computer charting system. Effect on the initial care of health care workers exposed to body fluids
The DOI matches its OpenAlex record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
CONTEXT: While clinical guidelines are considered an important mechanism to improve the quality of medical care, problems with implementation may limit their effectiveness. Few empirical data exist about the effect of computer-based systems for application of clinical guidelines on quality of care. OBJECTIVE: To determine whether real-time presentation of clinical guidelines using an electronic medical record can increase compliance with guidelines. DESIGN: Prospective off-on-off, interrupted time series with intent-to-treat analysis. SETTING: University hospital emergency department. SUBJECTS: Patients were 280 health care workers (50 in the baseline control phase, 156 in the intervention phase, and 74 in the postintervention control phase) who presented for initial treatment of occupational body fluid exposures, including 89% (248/280) who sustained punctures and 81% (208/257) who were exposed to blood. Physicians included resident physicians and attending physicians working in the emergency department during the study. INTERVENTIONS: Implementation of a computer charting system that provides real-time information regarding history and recommendations for laboratory testing, treatment, and disposition based on rules derived from clinical guidelines. MAIN OUTCOME MEASURES: Quality of care as determined by essential items documented in the medical record and in aftercare instructions, compliance with testing and treatment guidelines, and total charges and percentage of charges attributable to guideline-endorsed activities. RESULTS: Mean percent documentation of 7 essential items regarding patient history in the medical record increased from 57% during the baseline period to 98% in the intervention phase (42% increase; 95% confidence interval [CI], 34%-49%) and 11 items in aftercare instruction increased from 31 % at baseline to 93% during the intervention phase (62% increase; 95% CI, 51%-74%), but both decreased to baseline when the computer system was removed. Percent compliance with 4 laboratory testing guidelines increased from 63% at baseline to 83% during the intervention phase (20% increase; 95% CI, 9%-31 %) but decreased to 52% when the computer system was removed. Compliance with 5 treatment guidelines increased from 83% at baseline to 96% during the intervention phase (13% increase; 95% CI, 9%-17%) and decreased to 84% following the intervention. Percentage of charges incurred for indicated laboratory tests and treatment increased from 44% at baseline to 81% during the intervention phase (37% increase; 95% CI, 22%-52%) and decreased to 36% following the intervention. Average total per-patient charges were $460, $384, and $373 in each phase, respectively. CONCLUSIONS: Use of a computer-based system for clinical guidelines for management of patients with occupational exposure to body fluids improved documentation, compliance with guidelines, and percentage of charges spent on indicated activities, while decreasing overall charges. The parameters returned to baseline when the computer system was removed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion, Dissemination, and Implementation: Who Should Do What?
LOMAS, J. (1993) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1993.tb26351.x · Cited by 397
Guidelines You Can Follow and Can Trust: An Ideal and an Example
McDonald, C. J. (1994) · JAMA · doi:10.1001/jama.1994.03510350082042 · Cited by 114
Cited by
Chaudhry, B., Wang, J., Wu, S., Maglione, M., Mojica, W., Roth, E., Morton, S. C., & Shekelle, P. G. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-10-200605160-00125 · Cited by 3,159
National Standards for Diabetes Self-Management Education
Funnell, M. M., Brown, T. L., Childs, B. P., Haas, L. B., Hosey, G. M., Jensen, B., Maryniuk, M., Peyrot, M., Piette, J. D., Reader, D., et al. (2009) · Diabetes Care · doi:10.2337/dc09-s087 · Cited by 1,350
HAYRINEN, K., SARANTO, K., & NYKANEN, P. (2008) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2007.09.001 · Cited by 1,297
Rotter, T., Kinsman, L., James, E. L., Machotta, A., Gothe, H., Willis, J., Snow, P., & Kugler, J. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006632.pub2 · Cited by 800
National Standards for Diabetes Self-Management Education
Funnell, M. M., Brown, T. L., Childs, B. P., Haas, L. B., Hosey, G. M., Jensen, B., Maryniuk, M., Peyrot, M., Piette, J. D., Reader, D., et al. (2008) · Diabetes Care · doi:10.2337/dc08-s097 · Cited by 497
Metadata
- Authors
- Schriger, D. L.
- Venue
- JAMA
- Publisher
- American Medical Association
- Published
- 1997-11-19
- Volume
- 278
- Issue
- 19
- Pages
- 1585-1590
- ISSN
- 0002-9955 (ISSN-L)
- OpenAlex
- W4230466984
- Cited by
- 114
- References
- 2
- FWCI
- 28.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementation of clinical guidelines using a computer charting system. Effect on the initial care of health care workers exposed to body fluids. https://app.cochat.ai/papers/10.1001/jama.278.19.1585
- The paper
- Schriger, D. L. (1997). Implementation of clinical guidelines using a computer charting system. Effect on the initial care of health care workers exposed to body fluids. JAMA. https://doi.org/10.1001/jama.278.19.1585
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.