E5 Murine Monoclonal Antiendotoxin Antibody in Gram-Negative Sepsis<SUBTITLE>A Randomized Controlled Trial</SUBTITLE>

Angus, Derek C.·2000·JAMA

Abstract

CONTEXT: Knowledge and understanding of gram-negative sepsis have grown over the past 20 years, but the ability to treat severe sepsis successfully has not. OBJECTIVE: To assess the efficacy and safety of E5 in the treatment of patients with severe gram-negative sepsis. DESIGN: A multicenter, double-blind, randomized, placebo-controlled trial conducted at 136 US medical centers from April 1993 to April 1997, designed with 90% power to detect a 25% relative risk reduction, incorporating 2 planned interim analyses. SETTING: Intensive care units at university medical centers, Veterans Affairs medical centers, and community hospitals. PATIENTS: Adults aged 18 years or older, with signs and symptoms consistent with severe sepsis and documented or probable gram-negative infection. INTERVENTION: Patients were assigned to receive 2 doses of either E5, a murine monoclonal antibody directed against endotoxin (n = 550; 2 mg/kg per day by intravenous infusion 24 hours apart) or placebo (n = 552). MAIN OUTCOME MEASURES: The primary end point was mortality at day 14; secondary end points were mortality at day 28, adverse event rates, and 14-day and 28-day mortality in the subgroup without shock at presentation. RESULTS: The trial was stopped after the second interim analysis. A total of 1090 patients received study medication and 915 had gram-negative infection confirmed by culture. There were no statistically significant differences in mortality between the E5 and placebo groups at either day 14 (29.7% vs 31.1%; P = .67) or day 28 (38.5% vs 40.3%; P = .56). Patients presenting without shock had a slightly lower mortality when treated with E5 but the difference was not significant (28.9% vs 33.0% for the E5 and placebo groups, respectively, at day 28; P = .32). There was a similar profile of adverse event rates between E5 and placebo. CONCLUSIONS: Despite adequate sample size and high enrollment of patients with confirmed gram-negative sepsis, E5 did not improve short-term survival. Current study rationale and designs should be carefully reviewed before further large-scale studies of patients with sepsis are conducted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.283.13.1723

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 266

Metadata

Authors
Angus, D. C.
Venue
JAMA
Published
2000-04-05
Volume
283
Issue
13
Pages
1723
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2042956469
Cited by
266
References
1
FWCI
14.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: E5 Murine Monoclonal Antiendotoxin Antibody in Gram-Negative Sepsis<SUBTITLE>A Randomized Controlled Trial</SUBTITLE>. https://app.cochat.ai/papers/10.1001/jama.283.13.1723
The paper
Angus, D. C. (2000). E5 Murine Monoclonal Antiendotoxin Antibody in Gram-Negative Sepsis<SUBTITLE>A Randomized Controlled Trial</SUBTITLE>. JAMA. https://doi.org/10.1001/jama.283.13.1723

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.