CoChat

Diagnostic Accuracy of a Bedside D-dimer Assay and Alveolar Dead-Space Measurement for Rapid Exclusion of Pulmonary Embolism: A Multicenter Study

Kline, Jeffrey A. · 2001 · JAMA
Cited by 128

The DOI matches its Crossref record.

Abstract

CONTEXT: A previous study suggested that the combination of a normal D-dimer assay and normal alveolar dead-space fraction is a highly sensitive screening test for pulmonary embolism (PE). OBJECTIVE: To determine if the combination of a normal alveolar dead-space fraction (volume of alveolar dead space/tidal volume </=20%) and a normal whole-blood agglutination D-dimer assay can exclude PE in emergency department (ED) patients. DESIGN: Prospective, noninterventional study conducted in 1998-1999. Study data were obtained prior to standard testing for PE, consisting of radionuclide lung scanning or contrast-enhanced computed tomography and 6-month follow-up plus selective use of venous ultrasonography and pulmonary angiography. Imaging studies were interpreted by blinded observers. SETTING: Six urban teaching hospitals in the United States. PATIENTS: A total of 380 hemodynamically stable ED patients aged 18 years or older with suspected acute PE. MAIN OUTCOME MEASURES: Sensitivity and specificity for PE with a positive test defined as having either alveolar dead-space fraction or D-dimer assay results abnormal. Alveolar dead-space fraction was determined by subtracting airway dead space from physiological dead space (determined using the modified Bohr equation) and D-dimer assay, assayed at bedside using 20 microL of arterial blood. RESULTS: Pulmonary embolism was diagnosed in 64 patients (16.8%), of those 20 had an abnormal D-dimer assay result, 3 had an abnormal alveolar dead-space fraction, 40 had abnormal results in both, and 1 had normal results for both tests. The sensitivity for diagnosis of PE was 98.4% (95% confidence interval [CI], 91.6%-100.0%). Among the 316 patients without PE, both D-dimer and dead-space results were normal in 163, for a specificity of 51.6% (95% CI, 46.1%-57.1%). Posterior probability of PE with normal results on both tests was 0.75% (95% CI, 0%-3.4%). CONCLUSION: In this multicenter study of ED patients, a normal D-dimer assay result plus a normal alveolar dead-space fraction was associated with a low prevalence of PE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.285.6.761

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 128

Metadata

Authors
Kline, J. A.
Venue
JAMA
Published
2001-02-14
Volume
285
Issue
6
Pages
761
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W1986486333
Cited by
128
References
0
FWCI
7.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Accuracy of a Bedside D-dimer Assay and Alveolar Dead-Space Measurement for Rapid Exclusion of Pulmonary Embolism: A Multicenter Study. https://app.cochat.ai/papers/10.1001/jama.285.6.761
The paper
Kline, J. A. (2001). Diagnostic Accuracy of a Bedside D-dimer Assay and Alveolar Dead-Space Measurement for Rapid Exclusion of Pulmonary Embolism: A Multicenter Study. JAMA. https://doi.org/10.1001/jama.285.6.761

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.