Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 212

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Evaluation of Decision Rules for Referring Women for Bone Densitometry by Dual-Energy X-ray Absorptiometry

Cadarette, Suzanne M. · 2001 · JAMA

Abstract

CONTEXT: Identification of women with low bone mineral density (BMD) is an important strategy in reducing the incidence of osteoporotic fractures. However, screening all women is not recommended. OBJECTIVES: To assess the diagnostic properties of 4 decision rules--Simple Calculated Osteoporosis Risk Estimation (SCORE), Osteoporosis Risk Assessment Instrument (ORAI), Age, Body Size, No Estrogen (ABONE), and body weight less than 70 kg (weight criterion)--for selecting women for dual-energy x-ray absorptiometry (DXA) testing and to compare results with recommendations made in the National Osteoporosis Foundation (NOF) practice guidelines. DESIGN AND SETTING: Analysis of data from the Canadian Multicentre Osteoporosis Study, a population-based community sample, collected from 9 study centers across Canada between February 1996 and September 1997. PARTICIPANTS: Postmenopausal women aged 45 years or older (N = 2365) without bone disease who had DXA data for the femoral neck, data to apply selection criteria, and who were not currently taking estrogens or who had been taking hormone replacement therapy for 5 or more years. MAIN OUTCOME MEASURES: Sensitivity, specificity, and area under the receiver operating characteristic (AUROC) curve of each of the 4 decision rules and the NOF guidelines for identifying women with a BMD T score of less than -1.0 SD, less than -2.0 SD, and no more than -2.5 SD at the femoral neck, and percentages of women recommended for testing, stratified by BMD level and age. RESULTS: The percent of women with a BMD T score less than -1, less than -2, and no more than -2.5 were 68.3%, 25.4%, and 10.0%, respectively. The AUROC curves were greatest using SCORE and ORAI. The sensitivity for identifying women with a BMD T score of less than -2.0 was 93.7% (95% confidence interval [CI], 91.8%-95.6%) using the NOF guidelines and was 97.5% (95% CI, 96.3%-98.8%), 94.2% (95% CI, 92.3%-96.1%), 79.1% (95% CI, 75.9%-82.3%), and 79.6% (95% CI, 76.4%-82.8%), respectively, using the SCORE, ORAI, ABONE, and weight criterion. However, the NOF guidelines also resulted in 74.4% (95% CI, 71.3%-77.6%) of women with a normal BMD (T score of -1.0 or higher) being tested compared with 69.2% (95% CI, 65.9%-72.5%), 56.3% (95% CI, 52.7%-59.8%), 35.8% (95% CI, 32.4%-39.2%), and 38.1% (95% CI, 34.6%-41.6%), respectively, using the 4 decision rules. Assessments suggest that ABONE and weight criterion are not useful case-finding approaches. CONCLUSION: The SCORE and ORAI decision rules are better than the NOF guidelines at targeting BMD testing in high-risk patients. The acceptability of these rules in clinical practice merits further investigation given their potential effect on the use of densitometry services.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.286.1.57

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 212

Metadata

Authors
Cadarette, S. M.
Venue
JAMA
Published
2001-07-04
Volume
286
Issue
1
Pages
57
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W1979065599
Cited by
212
References
6
FWCI
17.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.