CoChat

Association Between Pulse Pressure and Mortality in Patients Undergoing Maintenance Hemodialysis

Klassen, Preston S. · 2002 · JAMA
Cited by 392

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Abstract

CONTEXT: Although increased blood pressure is associated with adverse outcomes in the general population, elevated blood pressure is associated with decreased mortality in patients with end-stage renal disease undergoing maintenance hemodialysis. Recent investigations in the general population have demonstrated the predictive utility of pulse pressure (systolic minus diastolic blood pressure), a measure reflecting the pulsatile nature of the cardiac cycle. OBJECTIVES: To estimate the relationship between pulse pressure and mortality in patients undergoing maintenance hemodialysis and to test our hypothesis that an increasing pulse pressure would be associated with increased risk of death up to 1 year despite the inverse relationship between conventional blood pressure measures and mortality in patients with end-stage renal disease. DESIGN, SETTING, AND PATIENTS: Retrospective cohort investigation of patients with end-stage renal disease undergoing maintenance hemodialysis at 782 hemodialysis facilities throughout the United States. Of 44 069 eligible patients as of January 1, 1998, 37 069 with complete demographic data were included in the analyses of clinical and laboratory data collected from October 1 through December 31, 1997. Patients were followed up through December 31, 1998. MAIN OUTCOME MEASURES: The primary study outcome was death at 1 year. A secondary outcome was the magnitude of the pulse pressure. RESULTS: The final patient cohort was similar to national averages with respect to age, sex, race, and diabetic status. Mean (SD) pulse pressures before dialysis were 75.0 (15.0) mm Hg and 66.9 (13.9) mm Hg after dialysis. By the end of the 1-year follow-up, 5731 patients (18.4%) died. After adjusting for level of systolic blood pressure, multivariable Cox proportional hazards modeling showed a direct and consistent relationship between increasing pulse pressure and increasing death risk. Each incremental elevation of 10 mm Hg in postdialysis pulse pressure was associated with a 12% increase in the hazard for death (hazard ratio, 1.12; 95% confidence interval, 1.06-1.18). Postdialysis systolic blood pressure was inversely related to mortality with a 13% decreased hazard for death for each incremental elevation of 10 mm Hg (hazard ratio, 0.87; 95% confidence interval, 0.84-0.90). In a multivariable linear regression model, important variables directly associated with elevated pulse pressure included age, diabetes, white race, female sex, and number of years receiving dialysis (all P<.001). CONCLUSIONS: Pulse pressure is associated with risk of death in a large, nationally representative sample of patients undergoing maintenance hemodialysis. The recognition of pulse pressure as an important correlate of mortality in patients receiving dialysis highlights the need to investigate the relationship between potential therapeutic implications of conduit vessel function and clinical outcomes in patients with end-stage renal disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.287.12.1548

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 392

Metadata

Authors
Klassen, P. S.
Venue
JAMA
Published
2002-03-27
Volume
287
Issue
12
Pages
1548
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2059513418
Cited by
392
References
33
FWCI
21.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.